510(k) · Cleared
Recalled · 2007Smith & Nephew Xenon Light Sources and Accessories
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Smith & Nephew, Inc. · FFS Image, Illumination, Fiberoptic, For Endoscope
Cleared on Jan 20, 2000 after a 48-day review. The FDA summary names its predicate without a number. 2 later devices descend from it. It has been recalled once.
- Decided
- Jan 20, 2000
- Review
- 48 days
- Class
- Class II
- Product code
- FFS
- Recalls
- 1
- Predicates
- 0
2 later devices descend from it, 1 citing it directly.
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K994084 | Smith & Nephew Xenon Light Sources and Accessories | Smith & Nephew, Inc. | 2000 | — |
| +1 | K032387 | Trivex System | Smith & Nephew, Inc. | 2003 | 1 |
| +2 | K212894 | PhasTIPP | LeMaitre Vascular, Inc. | 2022 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FFS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Smith & Nephew Xenon Light Sources, Light Guides and accessories Named without a submission number |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K032387 | Trivex System | 2003 | 1 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Apr 9, 2007 | Not classified | Z-0840-2007 | Nonconforming Material/Component | Several units were manufactured using a power supply that contains a 1 amp fuse where a 5 amp fuse is required. When the unit's power supply draws more that 1A, the fuse will fail causing the light to cease operating. The problem can… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K032387 (Smith & Nephew, Inc., 2003) has gone furthest, with 1 descendant of its own.
How does its category compare?
All FFS devicesFFS Image, Illumination, Fiberoptic, For Endoscope: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FFS
3in 2007
2026 to Oct 25, outlined.
Median 510(k) review, days · FFS
74in 2007
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FFS
1in 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FFS
5in 2024
MAUDE reports naming product code FFS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 74 | 1 | 12 |
| 2008 | 0 | — | 0 | 17 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 0 | — | 0 | 5 |
| 2011 | 0 | — | 0 | 7 |
| 2012 | 0 | — | 0 | 4 |
| 2013 | 0 | — | 0 | 10 |
| 2014 | 0 | — | 0 | 5 |
| 2015 | 0 | — | 0 | 4 |
| 2016 | 0 | — | 0 | 7 |
| 2017 | 0 | — | 0 | 19 |
| 2018 | 0 | — | 0 | 19 |
| 2019 | 0 | — | 0 | 17 |
| 2020 | 0 | — | 0 | 56 |
| 2021 | 0 | — | 0 | 57 |
| 2022 | 0 | — | 0 | 10 |
| 2023 | 0 | — | 0 | 6 |
| 2024 | 0 | — | 0 | 5 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Smith & Nephew Light Sources, light guides and accessories are indicated for use with the Subcutaneous Illuminator for the purpose of providing transillumination during endoscopic resection of superficial varicosities of the lower extremities.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K994084 · printed Nov 6, 2026
Cite this page
510(k) Report. “K994084: Smith & Nephew Xenon Light Sources and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K994084
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026