510(k) · Cleared
ClearedModification to Trident All Poly Cup
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Howmedica Osteonics Corp. · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Cleared on Mar 20, 2001 as substantially equivalent to K001956 (Howmedica Osteonics Corp., 2000) after a 47-day review. Its family tree reaches back 1 generation to 2000. 1 later device descends from it.
- Decided
- Mar 20, 2001
- Review
- 47 days
- Class
- Class II
- Product code
- JDI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K001956 (2000). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K012026Trident All Poly CupHowmedica Osteonics Corp. · 2001 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K001956 | Trident All Poly Cup | Howmedica Osteonics Corp. | 2000 | — |
| 0 (this device) | K010310 | Modification to Trident All Poly Cup | Howmedica Osteonics Corp. | 2001 | — |
| +1 | K012026 | Trident All Poly Cup | Howmedica Osteonics Corp. | 2001 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDI device
- #1 K253515 Zimmer Biomet OSS™ Orthopedic Salvage System…score 15.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K001956 | Trident All Poly CupSummary page 1…terilization of the subject device are identical to those of predicate device. The predicate device was found substantially equivalent via the 510(k) process in 510(k) #K001956. The predicate and subject devices are polyethylene acetabular components that are intended to replace the bearing portion of the… | 2000 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K012026 | Trident All Poly Cup | 2001 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All JDI devicesJDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDI
59in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDI
1,644in 2025
MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 26 | 696 |
| 2008 | 5 | 96 | 6 | 810 |
| 2009 | 3 | 65 | 3 | 964 |
| 2010 | 0 | — | 3 | 2,040 |
| 2011 | 2 | — | 5 | 3,160 |
| 2012 | 4 | 167 | 4 | 5,122 |
| 2013 | 3 | 176 | 11 | 5,206 |
| 2014 | 3 | 98 | 3 | 4,968 |
| 2015 | 3 | 190 | 1 | 4,906 |
| 2016 | 4 | 166 | 5 | 3,995 |
| 2017 | 1 | — | 5 | 6,135 |
| 2018 | 1 | — | 1 | 6,728 |
| 2019 | 2 | — | 1 | 7,407 |
| 2020 | 7 | 247 | 77 | 4,015 |
| 2021 | 3 | 162 | 0 | 3,170 |
| 2022 | 3 | 69 | 0 | 1,978 |
| 2023 | 2 | — | 0 | 1,635 |
| 2024 | 3 | 59 | 0 | 1,821 |
| 2025 | 1 | — | 1 | 1,644 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Trident All Poly Cup is a polyethylene acetabular component that is intended to replace the bearing portion of the acetabulum in primary or revision total hip arthroplasty. This cup is designed to be cemented into the acetabulum. These acetabular cups are intended to be used with any Howmedica Osteonics' femoral head.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K010310 · printed Nov 5, 2026
Cite this page
510(k) Report. “K010310: Modification to Trident All Poly Cup.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K010310
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026