Recalled · Class II · 2023Olympus GF UC140P-AL5 Ultrasonic Endoscope with Aloka SSD-5500 Ultrasound System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Aloka Co., Ltd. · ITX Transducer, Ultrasonic, Diagnostic
Cleared on May 15, 2001 after a 15-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 1 of the 74 devices in its family, counting itself, has a Class I recall. 73 later devices descend from it. It has been recalled 4 times.
- Decided
- May 15, 2001
- Review
- 15 days
- Class
- Class II
- Product code
- ITX
- Recalls
- 4
- Predicates
- 0
73 later devices descend from it, 4 citing it directly. 1 of the 74 devices in this family, counting this one, has a Class I recall.
- This deviceK011314 Olympus GF UC140P-AL5 Ultrasonic Endoscope with Aloka SSD-5500…Aloka Co., Ltd. · 2001
- Descendant · cites it directly · 44 of its ownK031347 Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8Olympus Optical Co., Ltd. · 2003
- Descendant · 2 generations on · 43 of its ownK042140 Olympus BF Type UC160-OL8Olympus Corporation · 2004 · Recalled
- Descendant · 3 generations on · 28 of its ownK050503 Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation · 2005 · Recalled
- Descendant · cites it directly · 27 of its ownK051541 GF-UE160-AL5 Ultrasound EndoscopeOlympus America, Inc. · 2005 · Recalled
- Descendant · cites it directly · 15 of its ownK063683 Olympus Xeu-M60A Endoscopic Ultrasound Center; XGF-UM180 Ultrasonic…Olympus Medical Systems Corporation · 2007
Showing 5 of 73 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
- K193517 ViziShot 2 FLEX6 generations on · 2020
Most influential descendants
Showing 5 of 73 · See all- K031347Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8Olympus Optical Co., Ltd. · 2003 · cites it directly44descendants
- K042140Olympus BF Type UC160-OL8Olympus Corporation · 2004 · 2 generations on43descendants
- K050503Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation · 2005 · 3 generations on28descendants
- K051541GF-UE160-AL5 Ultrasound EndoscopeOlympus America, Inc. · 2005 · cites it directly27descendants
- K063683Olympus Xeu-M60A Endoscopic Ultrasound Center; XGF-UM180 Ultrasonic GastrovideoscopeOlympus Medical Systems Corporation · 2007 · cites it directly15descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K011314 | Olympus GF UC140P-AL5 Ultrasonic Endoscope with Aloka SSD-5500 Ultrasound System | Aloka Co., Ltd. | 2001 | — |
| +1 | K031347 | Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8 | Olympus Optical Co., Ltd. | 2003 | — |
| +2 | K042140 | Olympus BF Type UC160-OL8 | Olympus Corporation | 2004 | 1 |
| +3 | K050503 | Single Use Aspiration Needle NA-201SX-4022 | Olympus Medical Systems Corporation | 2005 | 5 |
| +1 | K051541 | GF-UE160-AL5 Ultrasound Endoscope | Olympus America, Inc. | 2005 | 2 |
| +1 | K063683 | Olympus Xeu-M60A Endoscopic Ultrasound Center; XGF-UM180 Ultrasonic… | Olympus Medical Systems Corporation | 2007 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
| 2007 | 3 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 1 | 0 |
| 2012 | 5 | 0 |
| 2013 | 1 | 0 |
| 2014 | 3 | 0 |
| 2015 | 3 | 0 |
| 2016 | 6 | 0 |
| 2017 | 3 | 0 |
| 2018 | 5 | 0 |
| 2019 | 7 | 0 |
| 2020 | 5 | 1 |
| 2021 | 1 | 0 |
| 2022 | 4 | 0 |
| 2023 | 5 | 0 |
| 2024 | 1 | 0 |
| 2025 | 7 | 0 |
| 2026 | 4 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ITX device
- #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (73)
See all 734 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K031347 | Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8 | 2003 | 44 |
| K051541 | GF-UE160-AL5 Ultrasound Endoscope | 2005 | 27 |
| K063683 | Olympus Xeu-M60A Endoscopic Ultrasound Center; XGF-UM180 Ultrasonic Gastrovideoscope | 2007 | 15 |
| K093395 | Olympus GF Type UC180, Olympus GF Type UCT180 Evis Exera II Ulatrasound Gastrovideoscope | 2010 | 1 |
Has anything in its family been recalled? (1 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 25, 2023 | Class II | Z-0333-2024 | Under Investigation by firm | Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead… |
| Mar 18, 2022 | Class II | Z-1034-2022 | Device Design | GF-UC140P-AL5 is no longer a compatible endoscope for reprocessing in the OER-Pro and presents an infection control risk to patients |
| Oct 16, 2020 | Class II | Z-0498-2021 | Device Design | A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections. |
| Oct 16, 2020 | Class II | Z-0499-2021 | Device Design | A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections. |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K193517ViziShot 2 FLEXOlympus Surgical Technologies America · 2020 · 6 generations on · ◆ in the 2020 descendants bar of FIG. 11 Class I recall
What does this lineage say?
- Of its descendants, K031347 (Olympus Optical Co., Ltd., 2003) has gone furthest, with 44 descendants of its own.
How does its category compare?
All ITX devicesITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · ITX
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ITX
126in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · ITX
2in 2025
Class I (10 since 2007) Class II/III not classified
Adverse event reports per year · ITX
571in 2025
MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 26 | 0 | 16 |
| 2008 | 12 | 73 | 4 | 39 |
| 2009 | 17 | 28 | 4 | 23 |
| 2010 | 10 | 42 | 4 | 30 |
| 2011 | 10 | 16 | 1 | 34 |
| 2012 | 7 | 25 | 1 | 29 |
| 2013 | 3 | 105 | 0 | 38 |
| 2014 | 4 | 41 | 1 | 43 |
| 2015 | 1 | — | 5 | 183 |
| 2016 | 4 | 151 | 0 | 269 |
| 2017 | 6 | 110 | 1 | 412 |
| 2018 | 2 | — | 15 | 130 |
| 2019 | 1 | — | 0 | 119 |
| 2020 | 3 | 120 | 3 | 116 |
| 2021 | 3 | 139 | 10 (10) | 146 |
| 2022 | 2 | — | 6 | 87 |
| 2023 | 6 | 213 | 1 | 138 |
| 2024 | 3 | 81 | 1 | 988 |
| 2025 | 4 | 126 | 2 | 571 |
| 2026 | 6 | 158 | 0 | — |
https://510kreport.com/device/K011314 · printed Nov 6, 2026
Cite this page
510(k) Report. “K011314: Olympus GF UC140P-AL5 Ultrasonic Endoscope with Aloka SSD-5500 Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K011314
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026