510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Olympus BF Type UC160-OL8

K042140510(k) TraditionalCleared Aug 18, 20049-day reviewClass II21 CFR 876.1500Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Olympus Corporation · ODG Endoscopic Ultrasound System, Gastroenterology-Urology

Cleared on Aug 18, 2004 as substantially equivalent to K021204 (Olympus Optical Co., Ltd., 2002) and 3 other predicates after a 9-day review. Its family tree reaches back 7 generations to 1989. 2 of the 92 devices in its family, counting itself, have a Class I recall. 43 later devices descend from it. It has been recalled once.

Decided
Aug 18, 2004
Review
9 days
Class
Class II
Product code
ODG
Recalls
1
Predicates
4

Its longest line of descent runs back 7 generations to K894632 (1989). 48 ancestors in all, the oldest K812810 (1981). 43 later devices descend from it, 3 citing it directly. 2 of the 92 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2003: 2 other ancestors, 1 with a Class I recall12002: 1 other ancestor2001: 2 other ancestors1998: 4 other ancestors1997: 8 other ancestors1996: 4 other ancestors1993: 3 other ancestors1991: 2 other ancestors2000: 1 other ancestor1999: 2 other ancestors1995: 3 other ancestors1992: 1 other ancestor1988: 1 other ancestor1986: 1 other ancestor1981: 1 other ancestor1994: 4 other ancestors1989: 1 other ancestor2007: 1 descendant cleared2005: 1 descendant cleared2012: 1 descendant cleared2009: 1 descendant cleared2015: 3 descendants cleared2016: 3 descendants cleared2010: 1 descendant cleared2008: 1 descendant cleared2020: 3 descendants cleared, 1 with a Class I recall12019: 6 descendants cleared2025: 6 descendants cleared2014: 2 descendants cleared2018: 2 descendants cleared2017: 3 descendants cleared2026: 3 descendants cleared2023: 3 descendants cleared2021: 1 descendant cleared2022: 1 descendant cleared2024: 1 descendant clearedK894632 · Model SSH-140A Ultrasound Imaging System · Toshiba America Medical Systems, In.C · 1989K941593 · Diagnostic Ultrasonic Transducer · Toshiba America Medical Systems, In.C · 1996K970047 · Phased Array Transducer - - PSK-20CT · Toshiba America Medical Systems, In.C · 1997K991710 · Ssa-370A/Powervision 6000 · Toshiba America Medical Systems, In.C · 1999K994096 · Sonoheart Hand-Carried Echocardiography System · Sonosite,Inc. · 1999K010591 · Olympus EU-C60 Eus Exera Compact Endoscopic Ultrasound Center · Olympus Optical Co., Ltd. · 2001 · recalledK031347 · Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8 · Olympus Optical Co., Ltd. · 200319801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 12 other ancestors, 1 with a Class I recall13 generations back: 14 other ancestors4 generations back: 7 other ancestors5 generations back: 4 other ancestors6 generations back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 11 descendants3 generations forward: 9 descendants4 generations forward: 9 descendants, 1 with a Class I recall15 generations forward: 8 descendants6 generations forward: 3 descendants K031347 · Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8 · Olympus Optical Co., Ltd. · 2003K010591 · Olympus EU-C60 Eus Exera Compact Endoscopic Ultrasound Center · Olympus Optical Co., Ltd. · 2001 · recalledK994096 · Sonoheart Hand-Carried Echocardiography System · Sonosite,Inc. · 1999K991710 · Ssa-370A/Powervision 6000 · Toshiba America Medical Systems, In.C · 1999K970047 · Phased Array Transducer - - PSK-20CT · Toshiba America Medical Systems, In.C · 1997K941593 · Diagnostic Ultrasonic Transducer · Toshiba America Medical Systems, In.C · 1996K894632 · Model SSH-140A Ultrasound Imaging System · Toshiba America Medical Systems, In.C · 1989−50+5
  1. Root · 7 generations backK894632 Model SSH-140A Ultrasound Imaging SystemToshiba America Medical Systems, In.C · 1989
  2. 6 generations backK941593 Diagnostic Ultrasonic TransducerToshiba America Medical Systems, In.C · 1996
  3. 5 generations backK970047 Phased Array Transducer - - PSK-20CTToshiba America Medical Systems, In.C · 1997
  4. 4 generations backK991710 Ssa-370A/Powervision 6000Toshiba America Medical Systems, In.C · 1999
  5. 3 generations backK994096 Sonoheart Hand-Carried Echocardiography SystemSonosite,Inc. · 1999
  6. 2 generations backK010591 Olympus EU-C60 Eus Exera Compact Endoscopic Ultrasound CenterOlympus Optical Co., Ltd. · 2001 · Recalled
  7. 1 generation backK031347 Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8Olympus Optical Co., Ltd. · 2003
  8. This deviceK042140 Olympus BF Type UC160-OL8Olympus Corporation · 2004
  9. Descendant · cites it directly · 28 of its ownK050503 Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation · 2005 · Recalled
  10. Descendant · cites it directly · 11 of its ownK070983 Olympus XBF-UC180F-DT8 Ultrasonic Bronchofibervideoscope Used with…Olympus Medical Systems Corporation · 2007 · Recalled
  11. Descendant · 2 generations on · 8 of its ownK093195 Echotip Ultra Endobronchial High Definition Ultasound Needle, Model…Cook Ireland, Ltd. · 2010
  12. Descendant · 3 generations on · 7 of its ownK160229 Echotip Ultra Endobronchial High Definition Ultrasound Needle…Cook Ireland, Ltd. · 2016
  13. Descendant · 2 generations on · 7 of its ownK142909 Flexible 19G EBUS NeedleSpiration, Inc. · 2015

Showing 5 of 43 descendants. See all descendants

Descendants cleared per year

2005: 12007: 12008: 12009: 12010: 12012: 12014: 22015: 32016: 32017: 32018: 22019: 62020: 32021: 12022: 12023: 32024: 12025: 62026: 3
2005high 6 (2019) · low 0 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 43 · See all
  • K050503Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation · 2005 · cites it directly28descendants
  • K070983Olympus XBF-UC180F-DT8 Ultrasonic Bronchofibervideoscope Used with Aloka SSD-Alpha 5/10…Olympus Medical Systems Corporation · 2007 · cites it directly11descendants
  • K093195Echotip Ultra Endobronchial High Definition Ultasound Needle, Model: Echo-HD-22-Ebus-OCook Ireland, Ltd. · 2010 · 2 generations on8descendants
  • K160229Echotip Ultra Endobronchial High Definition Ultrasound Needle, Echotip Procore…Cook Ireland, Ltd. · 2016 · 3 generations on7descendants
  • K142909Flexible 19G EBUS NeedleSpiration, Inc. · 2015 · 2 generations on7descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K894632Model SSH-140A Ultrasound Imaging SystemToshiba America Medical Systems, In.C1989—
−6K941593Diagnostic Ultrasonic TransducerToshiba America Medical Systems, In.C1996—
−5K970047Phased Array Transducer - - PSK-20CTToshiba America Medical Systems, In.C1997—
−4K991710Ssa-370A/Powervision 6000Toshiba America Medical Systems, In.C1999—
−3K994096Sonoheart Hand-Carried Echocardiography SystemSonosite,Inc.1999—
−2K010591Olympus EU-C60 Eus Exera Compact Endoscopic Ultrasound CenterOlympus Optical Co., Ltd.20012
−1K031347Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8Olympus Optical Co., Ltd.2003—
0 (this device)K042140Olympus BF Type UC160-OL8Olympus Corporation2004—
+1K050503Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation20055
+1K070983Olympus XBF-UC180F-DT8 Ultrasonic Bronchofibervideoscope Used with Aloka…Olympus Medical Systems Corporation20073
+2K093195Echotip Ultra Endobronchial High Definition Ultasound Needle, Model…Cook Ireland, Ltd.2010—
+3K160229Echotip Ultra Endobronchial High Definition Ultrasound Needle, Echotip Procore…Cook Ireland, Ltd.2016—
+2K142909Flexible 19G EBUS NeedleSpiration, Inc.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198610
198810
198910
199120
199210
199330
199440
199530
199640
199780
199840
199920
200010
200120
200210
200321

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200710
200810
200910
201010
201210
201420
201530
201630
201730
201820
201960
202031
202110
202210
202330
202410
202560
202630
FIG. 1 — Lineage of K042140, 1989–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODG device

  1. #1 K251859 EVIS EUS Ultrasound Gastrointestinal…score 14.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021204Olympus BF Type UM40
Summary page 2
…ical devices. Device Name #K Ultrasonic Bronchofibersco BEt UMO 021204 EVIS EXERA Ultrasonic Bronchofibervideoscope BE K033225 typeXPI6OF EU-CGO Compact Endoscopic ultr…
Olympus Optical Co., Ltd.2002—
*K033225Evis Exera Bronchofibervideoscope Olympus BF Type XP160F, Its Accessories and Ancillary…
Summary page 2
…#K Ultrasonic Bronchofibersco BEt UMO 021204 EVIS EXERA Ultrasonic Bronchofibervideoscope BE K033225 typeXPI6OF EU-CGO Compact Endoscopic ultrasound Center KOI 0591 EVIS EXERA Ultrasonic Gasro…
Olympus Optical Co., Ltd.20035
*K010591Olympus EU-C60 Eus Exera Compact Endoscopic Ultrasound Center
Summary page 3
…e and the gastrointestinal tract and surrounding organs. F. Comparison Technological Characteristics: The subject device operates identically to the predicate device (K01 0591) in that piezoelectric material in the transducer is used as an ultrasound source to transmit sound waves into the body. Sound…
Olympus Optical Co., Ltd.20012
*K031347Ultrasonic Gastrovideoscope, Type UC160P-AT8 and UCT160-AT8Olympus Optical Co., Ltd.2003—

What descends from it? (43)

See all 43

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K050503Single Use Aspiration Needle NA-201SX-4022Olympus Medical Systems Corporation200528
K070983Olympus XBF-UC180F-DT8 Ultrasonic Bronchofibervideoscope Used with Aloka SSD-Alpha 5/10…Olympus Medical Systems Corporation200711
K121035Fujinon/Fujifilm Ultrasonic Endoscope EB-530USFujifilm Medical System U.S.A., Inc.20122

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 8, 2018Class IIZ-3303-2018OtherThe attachment of non-Olympus accessories to the bronchoscope s instrument channel port may have resulted in more applied force than expected and lead to loosening of the instrument channel port.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K023984Modification to Olympus Bronchoscopes BF-40 Series, BF-240 Series, and BF-160 SeriesThe Olympus Optical Co. · 2003 · 2 generations back · ◆ in the 2003 ancestors bar of FIG. 114 Class I recalls
  • K193517ViziShot 2 FLEXOlympus Surgical Technologies America · 2020 · 4 generations on · ◆ in the 2020 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 1.3 years on median.
  • 12 of the 48 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K050503 (Olympus Medical Systems Corporation, 2005) has gone furthest, with 28 descendants of its own.

How does its category compare?

All ODG devices

ODG Endoscopic Ultrasound System, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · ODG

2in 2025

2009: 22011: 22013: 22014: 12016: 12017: 42018: 32019: 12020: 22021: 12022: 42023: 12024: 12025: 22026 (partial year): 2
2007high 4 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODG

71in 2022

2017: 75 days median2018: 30 days median2022: 71 days median
2007high 75 (2017) · low 30 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODG

4in 2020

2020: 42026 (partial year): 4
2007high 4 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODG

3,569in 2025

2008: 12009: 32010: 22011: 132012: 62013: 22014: 12015: 112016: 502017: 822018: 662019: 962020: 4452021: 1,2342022: 1,8322023: 2,0782024: 1,9042025: 3,569
2007high 3,569 (2025) · low 0 (2007)2025

MAUDE reports naming product code ODG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20092—03
20100—02
20112—013
20120—06
20132—02
20141—01
20150—011
20161—050
2017475082
2018330066
20191—096
20202—4445
20211—01,234
202247101,832
20231—02,078
20241—01,904
20252—03,569
20262—4—

What is it indicated for?

Endoscopic real-time ultrasonic imaging, ultrasound guided needle aspiration and other endoscopic procedures as follows:

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042140: Olympus BF Type UC160-OL8.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042140

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026