Howmedica Osteonics Corp. · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Cleared on Jun 15, 2001 after a 21-day review. The FDA summary names its predicate without a number. 40 later devices descend from it.
- Decided
- Jun 15, 2001
- Review
- 21 days
- Class
- Class II
- Product code
- JDI
- Recalls
- None
- Predicates
- 0
40 later devices descend from it, 9 citing it directly.
- This deviceK011623 Exeter Hip System with V40 TaperHowmedica Osteonics Corp. · 2001
- Descendant · cites it directly · 37 of its ownK110290 Exeter Hip StemHowmedica Osteonics Corp. · 2011 · Recalled
- Descendant · cites it directly · 18 of its ownK031730 36MM Orthinox V40 Femoral Head ComponentsHowmedica Osteonics Corp. · 2003
- Descendant · cites it directly · 17 of its ownK153345 Stryker Orthopaedics Hip Systems Labeling UpdateStryker Orthopaedics · 2016 · Recalled
- Descendant · cites it directly · 8 of its ownK173499 Exeter V40 Femoral Stem Hip System, Orthinox V40 Femoral HeadsStryker Orthopaedics · 2018 · Recalled
- Descendant · 2 generations on · 7 of its ownK182468 Trident X3 Acetabular Inserts, ADM and MDM X3 Acetabular Inserts…Howmedica Osteonics Corp. A.K.A. Stryker Orthopaedics · 2019
Showing 5 of 40 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 40 · See all- K110290Exeter Hip StemHowmedica Osteonics Corp. · 2011 · cites it directly37descendants
- K03173036MM Orthinox V40 Femoral Head ComponentsHowmedica Osteonics Corp. · 2003 · cites it directly18descendants
- K153345Stryker Orthopaedics Hip Systems Labeling UpdateStryker Orthopaedics · 2016 · cites it directly17descendants
- K173499Exeter V40 Femoral Stem Hip System, Orthinox V40 Femoral HeadsStryker Orthopaedics · 2018 · cites it directly8descendants
- K182468Trident X3 Acetabular Inserts, ADM and MDM X3 Acetabular Inserts, Accolade II Hip SystemHowmedica Osteonics Corp. A.K.A. Stryker Orthopaedics · 2019 · 2 generations on7descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K011623 | Exeter Hip System with V40 Taper | Howmedica Osteonics Corp. | 2001 | — |
| +1 | K110290 | Exeter Hip Stem | Howmedica Osteonics Corp. | 2011 | 1 |
| +1 | K031730 | 36MM Orthinox V40 Femoral Head Components | Howmedica Osteonics Corp. | 2003 | — |
| +1 | K153345 | Stryker Orthopaedics Hip Systems Labeling Update | Stryker Orthopaedics | 2016 | 1 |
| +1 | K173499 | Exeter V40 Femoral Stem Hip System, Orthinox V40 Femoral Heads | Stryker Orthopaedics | 2018 | 2 |
| +2 | K182468 | Trident X3 Acetabular Inserts, ADM and MDM X3 Acetabular Inserts, Accolade II… | Howmedica Osteonics Corp. A.K.A. Stryker Orthopaedics | 2019 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2011 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 4 | 0 |
| 2017 | 2 | 0 |
| 2018 | 3 | 0 |
| 2019 | 4 | 0 |
| 2020 | 2 | 0 |
| 2021 | 3 | 0 |
| 2022 | 6 | 0 |
| 2023 | 3 | 0 |
| 2024 | 3 | 0 |
| 2025 | 4 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDI device
- #1 K253515 Zimmer Biomet OSS™ Orthopedic Salvage System…score 15.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Exeter Hip System Named without a submission number |
What descends from it? (40)
See all 409 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K110290 | Exeter Hip Stem | 2011 | 37 |
| K031730 | 36MM Orthinox V40 Femoral Head Components | 2003 | 18 |
| K153345 | Stryker Orthopaedics Hip Systems Labeling Update | 2016 | 17 |
| K173499 | Exeter V40 Femoral Stem Hip System, Orthinox V40 Femoral Heads | 2018 | 8 |
| K152084 | Bencox M Stem (Bencox Hip System) and Bencox ID Cemented Stem (with Centralizer) &… | 2016 | 7 |
| K193429 | Exeter V40 Femoral Stem, Exeter X3 RimFit Cup | 2020 | 6 |
| K191414 | EXETER Centralizer, EXETER 2.5mm Plug | 2019 | 5 |
| K142761 | Corin TaperFit Hip Stem | 2015 | 4 |
| K162125 | MALUC™ Total Hip Arthroplasty System | 2017 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K110290 (Howmedica Osteonics Corp., 2011) has gone furthest, with 37 descendants of its own.
How does its category compare?
All JDI devicesJDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDI
59in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDI
1,644in 2025
MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 26 | 696 |
| 2008 | 5 | 96 | 6 | 810 |
| 2009 | 3 | 65 | 3 | 964 |
| 2010 | 0 | — | 3 | 2,040 |
| 2011 | 2 | — | 5 | 3,160 |
| 2012 | 4 | 167 | 4 | 5,122 |
| 2013 | 3 | 176 | 11 | 5,206 |
| 2014 | 3 | 98 | 3 | 4,968 |
| 2015 | 3 | 190 | 1 | 4,906 |
| 2016 | 4 | 166 | 5 | 3,995 |
| 2017 | 1 | — | 5 | 6,135 |
| 2018 | 1 | — | 1 | 6,728 |
| 2019 | 2 | — | 1 | 7,407 |
| 2020 | 7 | 247 | 77 | 4,015 |
| 2021 | 3 | 162 | 0 | 3,170 |
| 2022 | 3 | 69 | 0 | 1,978 |
| 2023 | 2 | — | 0 | 1,635 |
| 2024 | 3 | 59 | 0 | 1,821 |
| 2025 | 1 | — | 1 | 1,644 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The subject Exeter V40™ Hip System components are intended for use in total hip replacement. They are intended for cemented use only. The subject components are intended for use with any Howmedica Osteonics Corp. acetabular component featuring a polyethylene bearing surface.
Indications:
Noninflammatory joint disease including osteoarthritis and avascular necrosis,
Rheumatoid arthritis,
Correction of functional deformity,
Revision procedures where other treatments or devices have failed,
Treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K011623 · printed Nov 5, 2026
Cite this page
510(k) Report. “K011623: Exeter Hip System with V40 Taper.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011623
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026