510(k) · Cleared
ClearedDeep Gray
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cortechs Labs, Inc. · LLZ System, Image Processing, Radiological
Cleared on Nov 2, 2001 as substantially equivalent to K002519 (Vital Images, Inc., 2000) and 1 other predicate after an 85-day review. Its family tree reaches back 2 generations to 1991.
- Decided
- Nov 2, 2001
- Review
- 85 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K913770 (1991). 3 ancestors in all. No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K913770 | Advantage V.S. CT/MR Rad Diagnostic Workstation | General Electric Co. | 1991 | — |
| −1 | K963345 | Advantage Windows Tissue Volume Option | GE Medical Systems | 1996 | — |
| 0 (this device) | K012563 | Deep Gray | Cortechs Labs, Inc. | 2001 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K002519 | Vitrea 2, Version 2.1Summary page 2…ay Page 6 of 26 Revision: 1.0 Abbreviated 510(k) Submission Date: 7/31/2001 Substantially Equivalent To: Vitrea 2, version 2.1 Advantage Windows Tissue Volume Option (K002519) (K963345) Vital Images, Inc. General Electric Medical Systems 3300 Fernbrook Lane North Suite 200 P.O. Box 414 Plymouth, MN 5… | 2000 |
| * | K963345 | Advantage Windows Tissue Volume OptionSummary page 2…of 26 Revision: 1.0 Abbreviated 510(k) Submission Date: 7/31/2001 Substantially Equivalent To: Vitrea 2, version 2.1 Advantage Windows Tissue Volume Option (K002519) (K963345) Vital Images, Inc. General Electric Medical Systems 3300 Fernbrook Lane North Suite 200 P.O. Box 414 Plymouth, MN 55447 Milwa… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 5.0 years on median.
- 1 of the 3 ancestors has a recall of any class.
- 12 other devices also cite its predicate K002519.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Visualization/Processing/Analysis of brain images from MR scanners.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K012563 · printed Nov 4, 2026
Cite this page
510(k) Report. “K012563: Deep Gray.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K012563
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026