510(k) · Cleared
ClearedZeus Microwrist Robotic Surgical System and Accessories
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Computer Motion, Inc. · NAY System, Surgical, Computer Controlled Instrument
Cleared on Sep 24, 2002 as substantially equivalent to K990144 (Intuitive Surgical, Inc., 2000) after a 167-day review. Its family tree reaches back 3 generations to 1994.
- Decided
- Sep 24, 2002
- Review
- 167 days
- Class
- Class II
- Product code
- NAY
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K930667 (1994). 5 ancestors in all, the oldest K931340 (1993). No later device cites it as a predicate yet.
- Root · 3 generations backK930667 Reusable Laparoscopic InstrumentsSnowden-Pencer · 1994 · Recalled
- 2 generations backK960400 Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line…Snowden-Pencer · 1996
- 1 generation backK990144 Intuitive Surgical Endoscopic Instruments, Intuitive Surgical…Intuitive Surgical, Inc. · 2000 · Recalled
- This deviceK021152 Zeus Microwrist Robotic Surgical System and AccessoriesComputer Motion, Inc. · 2002
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K930667 | Reusable Laparoscopic Instruments | Snowden-Pencer | 1994 | 15 |
| −2 | K960400 | Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line… | Snowden-Pencer | 1996 | — |
| −1 | K990144 | Intuitive Surgical Endoscopic Instruments, Intuitive Surgical Endoscopic… | Intuitive Surgical, Inc. | 2000 | 3 |
| 0 (this device) | K021152 | Zeus Microwrist Robotic Surgical System and Accessories | Computer Motion, Inc. | 2002 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NAY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NAY device
- #1 K232610 da Vinci Surgical System Model IS5000, da…score 32.9 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K990144 | Intuitive Surgical Endoscopic Instruments, Intuitive Surgical Endoscopic Instrument…Summary page 1…minimally invasive surgical instruments 2. The Intuitive Surgical da VinciTMEndoscopic Instrument Control System and Endoscopic Instruments, cleared to market via IC990144. 4) Description of the Device: The ZEUS@MicroWrist'" Surgical System (ZEUS System) and Accessories, consisting of a surge… | 2000 |
| * | — | A standard laparoscope with hand-held minimally invasive surgical instruments Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 2.2 years on median.
- 2 of the 5 ancestors have a recall of any class.
- 20 other devices also cite its predicate K990144.
How does its category compare?
All NAY devicesNAY System, Surgical, Computer Controlled Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · NAY
16in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NAY
117in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NAY
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · NAY
48,456in 2025
MAUDE reports naming product code NAY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 11 | 133 |
| 2008 | 4 | 189 | 3 | 224 |
| 2009 | 3 | 253 | 1 | 380 |
| 2010 | 1 | — | 0 | 623 |
| 2011 | 7 | 191 | 2 | 501 |
| 2012 | 4 | 106 | 1 | 1,552 |
| 2013 | 4 | 144 | 6 | 6,217 |
| 2014 | 9 | 143 | 25 | 6,135 |
| 2015 | 3 | 99 | 3 | 1,722 |
| 2016 | 8 | 197 | 1 | 1,077 |
| 2017 | 16 | 107 | 1 | 1,049 |
| 2018 | 15 | 152 | 2 | 1,074 |
| 2019 | 8 | 73 | 5 | 1,154 |
| 2020 | 9 | 212 | 0 | 1,558 |
| 2021 | 11 | 61 | 3 | 1,997 |
| 2022 | 6 | 57 | 3 | 5,727 |
| 2023 | 5 | 141 | 2 (1) | 10,898 |
| 2024 | 10 | 126 | 40 | 12,872 |
| 2025 | 16 | 117 | 1 | 48,456 |
| 2026 | 7 | 89 | 4 (1) | — |
What is it indicated for?
The ZEUS' MicroWristTMSurgical System (ZEUS System) and Accessories are intended to be used to assist a surgeon during procedures such as Laparoscopic Cholecystectomy and Nissen Fundoplication, to hold and position an endoscope, and to control laparoscopic instruments in performance of the surgical tasks of grasping, sharp cutting, blunt dissection, electro-cautery and suturing with knot placement. The ZEUS System is intended to be used by surgeons who…
Read the full statement (124 words)
The ZEUS' MicroWristTMSurgical System (ZEUS System) and Accessories are intended
to be used to assist a surgeon during procedures such as Laparoscopic Cholecystectomy
and Nissen Fundoplication, to hold and position an endoscope, and to control
laparoscopic instruments in performance of the surgical tasks of grasping, sharp cutting,
blunt dissection, electro-cautery and suturing with knot placement. The ZEUS System is
intended to be used by surgeons who are trained in minimally invasive surgery, have
successfully completed a ZEUS System training program, and are certified in accordance
with their respective hospital's customary practice for ZEUS System use. The ZEUS@
MicroWristTMSurgical System is intended to be used in an operating room environment
in which the ZEUS System, the operating surgeon and patient are in the same room.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K021152 · printed Nov 4, 2026
Cite this page
510(k) Report. “K021152: Zeus Microwrist Robotic Surgical System and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021152
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026