510(k) Report

510(k) · Cleared

Cleared

CLC2000 Catheter Patency Device

K021692510(k) TraditionalCleared Dec 4, 2003561-day reviewClass II21 CFR 880.5440

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Icu Medical, Inc. · FPA Set, Administration, Intravascular

Cleared on Dec 4, 2003 as substantially equivalent to K973167 (Icu Medical, Inc., 1997) after a 561-day review. Its family tree reaches back 3 generations to 1995. 29 later devices descend from it.

Decided
Dec 4, 2003
Review
561 days
Class
Class II
Product code
FPA
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K942988 (1995). 4 ancestors in all. 29 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor2010: 1 descendant cleared2025: 3 descendants cleared2013: 1 descendant cleared2021: 6 descendants cleared2017: 4 descendants cleared2014: 2 descendants cleared2020: 2 descendants cleared2016: 1 descendant cleared2023: 3 descendants cleared2019: 2 descendants cleared2026: 2 descendants cleared2024: 1 descendant cleared2022: 1 descendant clearedK942988 · Filtered Extension Sets · B. Braun of America, Inc. · 1995 · recalledK955585 · V2 Injection Site · B.Braun Medical, Inc. · 1996 · recalledK973167 · Positive Pressure Connector · Icu Medical, Inc. · 19971995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 6 descendants4 generations forward: 8 descendants5 generations forward: 8 descendants6 generations forward: 2 descendants7 generations forward: 2 descendants K973167 · Positive Pressure Connector · Icu Medical, Inc. · 1997K955585 · V2 Injection Site · B.Braun Medical, Inc. · 1996 · recalledK942988 · Filtered Extension Sets · B. Braun of America, Inc. · 1995 · recalled0+5
  1. Root · 3 generations backK942988 Filtered Extension SetsB. Braun of America, Inc. · 1995 · Recalled
  2. 2 generations backK955585 V2 Injection SiteB.Braun Medical, Inc. · 1996 · Recalled
  3. 1 generation backK973167 Positive Pressure ConnectorIcu Medical, Inc. · 1997
  4. This deviceK021692 CLC2000 Catheter Patency DeviceIcu Medical, Inc. · 2003
  5. Descendant · cites it directly · 28 of its ownK100434 Clave NeutronIcu Medical, Inc. · 2010 · Recalled
  6. Descendant · 2 generations on · 26 of its ownK132413 MZ1000Care Fusion · 2013
  7. Descendant · 3 generations on · 13 of its ownK140831 Maxzero Extension Set with Needless ConnectorCare Fusion · 2014
  8. Descendant · 3 generations on · 6 of its ownK170336 BD Nexiva Closed IV Catheter System (Single Port) with MaxZero…Becton, Dickinson and Company · 2017
  9. Descendant · 4 generations on · 5 of its ownK183399 BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2019 · Recalled

Showing 5 of 29 descendants. See all descendants

Descendants cleared per year

2010: 12013: 12014: 22016: 12017: 42019: 22020: 22021: 62022: 12023: 32024: 12025: 32026: 2
2010high 6 (2021) · low 0 (2011)2026

Most influential descendants

Showing 5 of 29 · See all
  • K100434Clave NeutronIcu Medical, Inc. · 2010 · cites it directly28descendants
  • K132413MZ1000Care Fusion · 2013 · 2 generations on26descendants
  • K140831Maxzero Extension Set with Needless ConnectorCare Fusion · 2014 · 3 generations on13descendants
  • K170336BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless ConnectorBecton, Dickinson and Company · 2017 · 3 generations on6descendants
  • K183399BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2019 · 4 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K942988Filtered Extension SetsB. Braun of America, Inc.199532
−2K955585V2 Injection SiteB.Braun Medical, Inc.199627
−1K973167Positive Pressure ConnectorIcu Medical, Inc.1997—
0 (this device)K021692CLC2000 Catheter Patency DeviceIcu Medical, Inc.2003—
+1K100434Clave NeutronIcu Medical, Inc.20103
+2K132413MZ1000Care Fusion2013—
+3K140831Maxzero Extension Set with Needless ConnectorCare Fusion2014—
+3K170336BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless…Becton, Dickinson and Company2017—
+4K183399BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc.20193

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201310
201420
201610
201740
201920
202020
202160
202210
202330
202410
202530
202620
FIG. 1 — Lineage of K021692, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FPA device

  1. #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973167Positive Pressure Connector
Summary page 1
…ce Common Name: Accessory, Intravenous Administration Device Classification Name: Same Equivalent Device: ICU Medical CLC2000 (K973167) B.Braun Safsite® (5110(K) number unknown) Device Description: The CLC2000 is a swab-able normally closed tw…
Icu Medical, Inc.1997—
*—B.Braun Safsite
Named without a submission number
—

Also cleared against K973167: 1 other device →

What descends from it? (29)

See all 29

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K100434Clave NeutronIcu Medical, Inc.201028

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 1.5 years on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K100434 (Icu Medical, Inc., 2010) has gone furthest, with 28 descendants of its own.
  • 1 other device also cites its predicate K973167.

How does its category compare?

All FPA devices

FPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FPA

11in 2025

2007: 162008: 182009: 102010: 232011: 122012: 212013: 132014: 222015: 172016: 122017: 172018: 42019: 72020: 102021: 132022: 142023: 142024: 72025: 112026 (partial year): 5
2007high 23 (2010) · low 4 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FPA

225in 2025

2007: 75 days median2008: 89 days median2009: 166 days median2010: 120 days median2011: 87 days median2012: 96 days median2013: 90 days median2014: 89 days median2015: 123 days median2016: 195 days median2017: 240 days median2018: 177 days median2019: 161 days median2020: 327 days median2021: 186 days median2022: 213 days median2023: 340 days median2024: 244 days median2025: 225 days median2026 (partial year): 266 days median
2007high 340 (2023) · low 75 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FPA

98in 2025

2007: 172008: 152009: 1662010: 582011: 282012: 16, 4 Class I2013: 642014: 242015: 62016: 102017: 132018: 42019: 132020: 1072021: 12022: 9, 5 Class I2023: 12, 4 Class I2024: 13, 1 Class I2025: 98, 1 Class I2026 (partial year): 10, 2 Class I
2007high 166 (2009) · low 1 (2021)2026

Class I (17 since 2007) Class II/III not classified

Adverse event reports per year · FPA

34,506in 2025

2007: 1,4992008: 1,9412009: 2,5122010: 2,5372011: 4,4072012: 4,9302013: 4,6512014: 4,6952015: 6,6252016: 8,4702017: 6,4622018: 6,5742019: 11,2272020: 9,5632021: 10,4142022: 13,3932023: 10,9162024: 47,2102025: 34,506
2007high 47,210 (2024) · low 1,499 (2007)2025

MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071675171,499
20081889151,941
2009101661662,512
201023120582,537
20111287284,407
2012219616 (4)4,930
20131390644,651
20142289244,695
20151712366,625
201612195108,470
201717240136,462
2018417746,574
201971611311,227
2020103271079,563
202113186110,414
2022142139 (5)13,393
20231434012 (4)10,916
2024724413 (1)47,210
20251122598 (1)34,506
2026526610 (2)—

What is it indicated for?

The CLC2000 is intended for use as an accessory to a vascular access device. The CLC2000 has been shown to reduce thrombotic occlusion within the internal catheter lumen and fibrin formation in an animal study. The CLC2000 is designed to assist in maintaining catheter patency. The CLC2000 does not require the use of needles and therefore will passively aid in the reduction of needlestick injuries.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K021692: CLC2000 Catheter Patency Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021692

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026