510(k) · Cleared
ClearedMaxzero Extension Set with Needless Connector
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Care Fusion · FPA Set, Administration, Intravascular
Cleared on Apr 15, 2014 as substantially equivalent to K132413 (Care Fusion, 2013) and 2 other predicates after a 13-day review. Its family tree reaches back 6 generations to 1995. 13 later devices descend from it.
- Decided
- Apr 15, 2014
- Review
- 13 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 6 generations to K942988 (1995). 16 ancestors in all. 13 later devices descend from it, 6 citing it directly.
- Root · 6 generations backK942988 Filtered Extension SetsB. Braun of America, Inc. · 1995 · Recalled
- 5 generations backK955585 V2 Injection SiteB.Braun Medical, Inc. · 1996 · Recalled
- 4 generations backK973167 Positive Pressure ConnectorIcu Medical, Inc. · 1997
- 3 generations backK021692 CLC2000 Catheter Patency DeviceIcu Medical, Inc. · 2003
- 2 generations backK100434 Clave NeutronIcu Medical, Inc. · 2010 · Recalled
- 1 generation backK132413 MZ1000Care Fusion · 2013
- This deviceK140831 Maxzero Extension Set with Needless ConnectorCare Fusion · 2014
- Descendant · cites it directly · 4 of its ownK162804 Q2 Low Pressure Power Injection Extension SetQuest Medical, Inc. · 2017
- Descendant · 2 generations on · 3 of its ownK182897 Velano Vascular Q2 Extension SetVelano Vascular · 2019
- Descendant · cites it directly · 3 of its ownK153293 Extension SetB.Braun Medical, Inc. · 2016 · Recalled
- Descendant · 3 generations on · 2 of its ownK200439 Velano ExT Extension SetVelano Vascular · 2021
- Descendant · 4 generations on · 0 of its ownK251257 nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with…Np Medical · 2025
Showing 5 of 13 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 13 · See all- K162804Q2 Low Pressure Power Injection Extension SetQuest Medical, Inc. · 2017 · cites it directly4descendants
- K182897Velano Vascular Q2 Extension SetVelano Vascular · 2019 · 2 generations on3descendants
- K153293Extension SetB.Braun Medical, Inc. · 2016 · cites it directly3descendants
- K200439Velano ExT Extension SetVelano Vascular · 2021 · 3 generations on2descendants
- K251257nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with nSyte Needle Free…Np Medical · 2025 · 4 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K942988 | Filtered Extension Sets | B. Braun of America, Inc. | 1995 | 32 |
| −5 | K955585 | V2 Injection Site | B.Braun Medical, Inc. | 1996 | 27 |
| −4 | K973167 | Positive Pressure Connector | Icu Medical, Inc. | 1997 | — |
| −3 | K021692 | CLC2000 Catheter Patency Device | Icu Medical, Inc. | 2003 | — |
| −2 | K100434 | Clave Neutron | Icu Medical, Inc. | 2010 | 3 |
| −1 | K132413 | MZ1000 | Care Fusion | 2013 | — |
| 0 (this device) | K140831 | Maxzero Extension Set with Needless Connector | Care Fusion | 2014 | — |
| +1 | K162804 | Q2 Low Pressure Power Injection Extension Set | Quest Medical, Inc. | 2017 | — |
| +2 | K182897 | Velano Vascular Q2 Extension Set | Velano Vascular | 2019 | — |
| +1 | K153293 | Extension Set | B.Braun Medical, Inc. | 2016 | 8 |
| +3 | K200439 | Velano ExT Extension Set | Velano Vascular | 2021 | — |
| +4 | K251257 | nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with nSyte Needle… | Np Medical | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 1999 | 2 | 0 |
| 2000 | 1 | 0 |
| 2003 | 1 | 0 |
| 2005 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 1 | 0 |
| 2012 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2016 | 1 | 0 |
| 2017 | 3 | 0 |
| 2019 | 1 | 0 |
| 2020 | 2 | 0 |
| 2021 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K132413 | MZ1000Summary page 1…Manufacturer 510(k) # Date Cleared MZ1000 Needleless Connector CareFusion K132413 August 29, 2013 Medegen Pressure Rated CareFusion (formerly K083472 Decemb… | 2013 |
| * | K083472 | Medegen Pressure Rated Extension SetsSummary page 1…or CareFusion K132413 August 29, 2013 Medegen Pressure Rated CareFusion (formerly K083472 December 9, 2008 Extension Sets Medlegen) _______________ Medle… | 2008 |
| * | K051499 | Intravascular Administration Set and Extension SetSummary page 1…Sets Medlegen) _______________ Medlegen Intravascular CareFusion (formerly K051499 June 22, 2005 Administration Set and Medegen) Extension Set _ _ _ _ _ _ _… | 2005 |
What descends from it? (13)
See all 136 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K162804 | Q2 Low Pressure Power Injection Extension Set | 2017 | 4 |
| K153293 | Extension Set | 2016 | 3 |
| K222780 | LILY Extension Tube and Needleless Connector | 2023 | 0 |
| K193088 | MaxZero Extension Sets with Needle-Free Connector (s) | 2020 | 0 |
| K171118 | Carefusion NeutraClear multi-fuse Extension Set with needle-free connector (s) | 2017 | 0 |
| K171957 | MaxZero Extension Sets with Needless Connector | 2017 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 3.1 years on median.
- 10 of the 16 ancestors have a recall of any class.
- Of its descendants, K162804 (Quest Medical, Inc., 2017) has gone furthest, with 4 descendants of its own.
- 5 other devices also cite its predicate K132413.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
Pressure Rated: The MaxZero multi fuse extension set with needleless connector(s) is for single use only. The extension set may be used for direct injection, intermittent infusion, continuous infusion or aspiration. This set may be used with power injector procedures to a maximum pressure of 325 psi at a flow rate of 10mL per second.
Non Pressure Rated: The MaxZero multi fuse extension set with needleless connector(s) is for single use only. The extension set may be used for direct injection, intermittent infusion, continuous infusion or aspiration.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K140831 · printed Nov 6, 2026
Cite this page
510(k) Report. “K140831: Maxzero Extension Set with Needless Connector.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140831
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026