510(k) · Cleared
ClearedTheriridge Block, Bone Graft Substitute
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Therics, Inc. · LYC Bone Grafting Material, Synthetic
Cleared on Mar 26, 2003 after a 113-day review. The FDA summary names its predicate without a number. 1 later device descends from it.
- Decided
- Mar 26, 2003
- Review
- 113 days
- Class
- Class II
- Product code
- LYC
- Recalls
- None
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK023998 Theriridge Block, Bone Graft SubstituteTherics, Inc. · 2003
- Descendant · cites it directly · 0 of its ownK070784 Inion BiorestoreInion OY · 2007
Most influential descendants
Showing 1 of 1 · See all- K070784Inion BiorestoreInion OY · 2007 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K023998 | Theriridge Block, Bone Graft Substitute | Therics, Inc. | 2003 | — |
| +1 | K070784 | Inion Biorestore | Inion OY | 2007 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2007 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LYC device
- #1 K253317 Cytrans™ Elashieldscore 14.3 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Interpore’s Pro Osteon 200 Named without a submission number |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K070784 | Inion Biorestore | 2007 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K070784 (Inion OY, 2007) has gone furthest, with 0 descendants of its own.
How does its category compare?
All LYC devicesLYC Bone Grafting Material, Synthetic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LYC
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LYC
267in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LYC
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LYC
2in 2025
MAUDE reports naming product code LYC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 80 | 0 | 23 |
| 2008 | 8 | 73 | 0 | 25 |
| 2009 | 14 | 100 | 1 | 25 |
| 2010 | 13 | 164 | 2 | 28 |
| 2011 | 9 | 224 | 0 | 21 |
| 2012 | 5 | 120 | 2 | 10 |
| 2013 | 2 | — | 0 | 12 |
| 2014 | 1 | — | 0 | 9 |
| 2015 | 0 | — | 0 | 14 |
| 2016 | 2 | — | 2 | 140 |
| 2017 | 0 | — | 0 | 19 |
| 2018 | 0 | — | 1 | 14 |
| 2019 | 0 | — | 0 | 15 |
| 2020 | 3 | 156 | 0 | 5 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 2 | — | 0 | 6 |
| 2023 | 0 | — | 0 | 9 |
| 2024 | 0 | — | 0 | 6 |
| 2025 | 3 | 267 | 0 | 2 |
| 2026 | 3 | 266 | 0 | — |
What is it indicated for?
TheriRidgeTMBlock Bone Graft Substitute is indicated and intended for the augmentation of deficient maxillary and mandibular alveolar ridges.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K023998 · printed Nov 4, 2026
Cite this page
510(k) Report. “K023998: Theriridge Block, Bone Graft Substitute.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K023998
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026