510(k) · Cleared
ClearedInion Biorestore
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Inion OY · LYC Bone Grafting Material, Synthetic
Cleared on Jul 24, 2007 as substantially equivalent to K000149 (Usbiomaterials Corp., 2000) and 4 other predicates after a 125-day review. Its family tree reaches back 3 generations to 1995.
- Decided
- Jul 24, 2007
- Review
- 125 days
- Class
- Class II
- Product code
- LYC
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 3 generations to K941780 (1995). 12 ancestors in all, the oldest K852682 (1985). No later device cites it as a predicate yet.
- Root · 3 generations backK941780 Orthovita BiogranOrthovita Co. · 1995
- 2 generations backK962494 Perioglas - Bioglass Bone Graft ParticulateUsbiomaterials Corp. · 1996
- 1 generation backK040278 Perioglas-Bioglass Bone Graft SubstituteNovabone Products, LLC · 2004
- This deviceK070784 Inion BiorestoreInion OY · 2007
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K941780 | Orthovita Biogran | Orthovita Co. | 1995 | — |
| −2 | K962494 | Perioglas - Bioglass Bone Graft Particulate | Usbiomaterials Corp. | 1996 | — |
| −1 | K040278 | Perioglas-Bioglass Bone Graft Substitute | Novabone Products, LLC | 2004 | — |
| 0 (this device) | K070784 | Inion Biorestore | Inion OY | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 1986 | 1 | 0 |
| 1993 | 1 | 0 |
| 1995 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
| 2003 | 1 | 0 |
| 2006 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LYC device
- #1 K253317 Cytrans™ Elashieldscore 14.3 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K000149 | Novabone-Bioglass Bone Graft ParticulateSummary page 1…iller; Synthetic resorbable bone graft material Regulation number: 872.3930 Predicate devices NovaBone®0 (KO000149) PerioGlass ® Biog-lass ® Bone Graft Particulate (K040278) Chronos-beta-TCP (K053022)… | 2000 |
| * | K040278 | Perioglas-Bioglass Bone Graft SubstituteSummary page 1…Regulation number: 872.3930 Predicate devices NovaBone®0 (KO000149) PerioGlass ® Biog-lass ® Bone Graft Particulate (K040278) Chronos-beta-TCP (K053022) Theriridg-eTM Block, Bone Graft Substitute (1(023998) In… | 2004 |
| * | K053022 | Synthes (Usa) Chronos-Beta-TCPSummary page 1…Predicate devices NovaBone®0 (KO000149) PerioGlass ® Biog-lass ® Bone Graft Particulate (K040278) Chronos-beta-TCP (K053022) Theriridg-eTM Block, Bone Graft Substitute (1(023998) Interpore 200 Porous H-ydroxyapatite (1(8609… | 2006 |
| * | K023998 | Theriridge Block, Bone Graft SubstituteSummary page 1…PerioGlass ® Biog-lass ® Bone Graft Particulate (K040278) Chronos-beta-TCP (K053022) Theriridg-eTM Block, Bone Graft Substitute (1(023998) Interpore 200 Porous H-ydroxyapatite (1(860983) Conformance with performance standards… | 2003 |
| * | K860983 | Interpore 200 Porous HydroxyapatiteSummary page 1…78) Chronos-beta-TCP (K053022) Theriridg-eTM Block, Bone Graft Substitute (1(023998) Interpore 200 Porous H-ydroxyapatite (1(860983) Conformance with performance standards No applicable mandatory performance standards exist for t… | 1986 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 3.4 years on median.
- None of the 12 ancestors has a recall.
- 7 other devices also cite its predicate K000149.
How does its category compare?
All LYC devicesLYC Bone Grafting Material, Synthetic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · LYC
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LYC
267in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LYC
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LYC
2in 2025
MAUDE reports naming product code LYC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 80 | 0 | 23 |
| 2008 | 8 | 73 | 0 | 25 |
| 2009 | 14 | 100 | 1 | 25 |
| 2010 | 13 | 164 | 2 | 28 |
| 2011 | 9 | 224 | 0 | 21 |
| 2012 | 5 | 120 | 2 | 10 |
| 2013 | 2 | — | 0 | 12 |
| 2014 | 1 | — | 0 | 9 |
| 2015 | 0 | — | 0 | 14 |
| 2016 | 2 | — | 2 | 140 |
| 2017 | 0 | — | 0 | 19 |
| 2018 | 0 | — | 1 | 14 |
| 2019 | 0 | — | 0 | 15 |
| 2020 | 3 | 156 | 0 | 5 |
| 2021 | 0 | — | 0 | 12 |
| 2022 | 2 | — | 0 | 6 |
| 2023 | 0 | — | 0 | 9 |
| 2024 | 0 | — | 0 | 6 |
| 2025 | 3 | 267 | 0 | 2 |
| 2026 | 3 | 266 | 0 | — |
What is it indicated for?
The INION BIORESTORETM implants are bone graft substitutes indicated for bony voids or gaps that are not intrinsic to the stability of the bony structure; packing into bony voids or gaps to fill and/or augment dental intraosseous, oral and craniomaxillofacial defects. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone, including: e.g., periodontal/infrabony defects; alveolar ridge augmentation (sinusotomy, osteotomy, cystectomy); dental extraction sites (ridge maintenance, implant preparation/placement); sinus lifts; cystic defects; and craniofacial augmentation.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070784 · printed Nov 3, 2026
Cite this page
510(k) Report. “K070784: Inion Biorestore.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K070784
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026