Cleared on Jun 19, 2003 as substantially equivalent to K020839 (Lumenis, Inc., 2002) after a 190-day review. Its family tree reaches back 6 generations to 1992. 756 later devices descend from it.
- Decided
- Jun 19, 2003
- Review
- 190 days
- Class
- Class II
- Product code
- GEX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 6 generations to K910422 (1992). 50 ancestors in all, the oldest K892514 (1990). 756 later devices descend from it, 5 citing it directly.
- Root · 6 generations backK910422 Model RD-1200 Ruby Laser SystemSpectrum Medical Technologies, Inc. · 1992
- 5 generations backK961279 Sharplan Lasers, Inc. Ruby Laser SystemSharplan Lasers, Inc. · 1996
- 4 generations backK962446 Sharplan Ruby Laser SystemSharplan Lasers, Inc. · 1997
- 3 generations backK974536 Photoderm HR SystemEsc Medical Systems, Ltd. · 1998
- 2 generations backK991935 Epilight Hair Removal System, Photoderm HR SystemEsc Medical Systems, Ltd. · 2000
- 1 generation backK020839 Quantum, Models SR, HR, DL; Vasculight, Models SR, HR, VS, VX, DLLumenis, Inc. · 2002
- This deviceK024093 Modified Lumenis Family of Intense Pulsed-Light (Ipl) and…Lumenis, Ltd. · 2003
- Descendant · cites it directly · 737 of its ownK033946 Lovely SystemMsq (M2), Ltd. · 2004
- Descendant · 2 generations on · 517 of its ownK042000 Modified MSQ Family of Lovely Light/Laser SystemsMsq (M2), Ltd. · 2004
- Descendant · 2 generations on · 402 of its ownK042630 Revlight Skin Care SystemSkincare Technology, Inc. · 2005
- Descendant · 2 generations on · 302 of its ownK041969 Aurora DSSyneron Medical, Ltd. · 2004
- Descendant · 3 generations on · 301 of its ownK050796 Aurora DS, DS ApplicatorSyneron Medical, Ltd. · 2005
Showing 5 of 756 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 756 · See all- K033946Lovely SystemMsq (M2), Ltd. · 2004 · cites it directly737descendants
- K042000Modified MSQ Family of Lovely Light/Laser SystemsMsq (M2), Ltd. · 2004 · 2 generations on517descendants
- K042630Revlight Skin Care SystemSkincare Technology, Inc. · 2005 · 2 generations on402descendants
- K041969Aurora DSSyneron Medical, Ltd. · 2004 · 2 generations on302descendants
- K050796Aurora DS, DS ApplicatorSyneron Medical, Ltd. · 2005 · 3 generations on301descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K910422 | Model RD-1200 Ruby Laser System | Spectrum Medical Technologies, Inc. | 1992 | — |
| −5 | K961279 | Sharplan Lasers, Inc. Ruby Laser System | Sharplan Lasers, Inc. | 1996 | — |
| −4 | K962446 | Sharplan Ruby Laser System | Sharplan Lasers, Inc. | 1997 | — |
| −3 | K974536 | Photoderm HR System | Esc Medical Systems, Ltd. | 1998 | — |
| −2 | K991935 | Epilight Hair Removal System, Photoderm HR System | Esc Medical Systems, Ltd. | 2000 | — |
| −1 | K020839 | Quantum, Models SR, HR, DL; Vasculight, Models SR, HR, VS, VX, DL | Lumenis, Inc. | 2002 | — |
| 0 (this device) | K024093 | Modified Lumenis Family of Intense Pulsed-Light (Ipl) and Combination Ipl… | Lumenis, Ltd. | 2003 | — |
| +1 | K033946 | Lovely System | Msq (M2), Ltd. | 2004 | — |
| +2 | K042000 | Modified MSQ Family of Lovely Light/Laser Systems | Msq (M2), Ltd. | 2004 | — |
| +2 | K042630 | Revlight Skin Care System | Skincare Technology, Inc. | 2005 | — |
| +2 | K041969 | Aurora DS | Syneron Medical, Ltd. | 2004 | — |
| +3 | K050796 | Aurora DS, DS Applicator | Syneron Medical, Ltd. | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1990 | 1 | 0 |
| 1991 | 3 | 0 |
| 1993 | 3 | 0 |
| 1994 | 7 | 0 |
| 1995 | 6 | 0 |
| 1996 | 7 | 0 |
| 1997 | 6 | 0 |
| 1998 | 4 | 0 |
| 1999 | 3 | 0 |
| 2000 | 3 | 0 |
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 3 | 0 |
| 2005 | 5 | 0 |
| 2006 | 9 | 0 |
| 2007 | 14 | 0 |
| 2008 | 23 | 0 |
| 2009 | 14 | 0 |
| 2010 | 17 | 0 |
| 2011 | 17 | 0 |
| 2012 | 16 | 0 |
| 2013 | 24 | 0 |
| 2014 | 28 | 0 |
| 2015 | 26 | 0 |
| 2016 | 36 | 0 |
| 2017 | 33 | 0 |
| 2018 | 33 | 0 |
| 2019 | 23 | 0 |
| 2020 | 43 | 0 |
| 2021 | 38 | 0 |
| 2022 | 52 | 0 |
| 2023 | 49 | 0 |
| 2024 | 82 | 0 |
| 2025 | 106 | 0 |
| 2026 | 65 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEX device
- #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K020839 | Quantum, Models SR, HR, DL; Vasculight, Models SR, HR, VS, VX, DLSummary page 1…uLiqht Family; Lyra'"; GentleYAGTM Predicate Device Manufacturer(s) Lumenis; Lumenis; Laserscope; Candela Predicate Device Reference(s) K020839; K020839; K020021; KO22951 Predicate Device Classification Laser Surgical Instrument for Use in General and Plastic Surger… | 2002 |
| † | K020021 | Lyra Surgical Laser System and Accessiories (ND:Yag Configuration) | 2002 |
| † | K022951 | Candela Gentle Yag Laser System, Variable Pulse Yag | 2003 |
What descends from it? (756)
See all 7565 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K033946 | Lovely System | 2004 | 737 |
| K060448 | Lumenis One Family of Systems; Lumenis One. | 2006 | 297 |
| K072564 | Alma Lasers Harmony XL Multi-Application Platform | 2008 | 266 |
| K043255 | Ellipse Light SPT | 2005 | 25 |
| K113018 | Apollo V+ Medical Platform, Apollo IV+ Medical Platform, Nice Station Light Based Platform | 2012 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 11 years and passes through 5 companies; a new generation was cleared every 1.7 years on median.
- 1 of the 50 ancestors has a recall of any class.
- Of its descendants, K033946 (Msq (M2), Ltd., 2004) has gone furthest, with 737 descendants of its own.
- 20 other devices also cite its predicate K020839.
How does its category compare?
All GEX devicesGEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEX
83in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEX
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEX
3in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GEX
2,720in 2025
MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 73 | 79 | 9 | 342 |
| 2008 | 107 | 86 | 2 | 232 |
| 2009 | 69 | 100 | 0 | 209 |
| 2010 | 50 | 96 | 4 | 1,711 |
| 2011 | 41 | 83 | 18 | 3,024 |
| 2012 | 45 | 118 | 5 | 2,000 |
| 2013 | 46 | 144 | 3 | 2,236 |
| 2014 | 61 | 147 | 6 | 2,036 |
| 2015 | 47 | 112 | 0 | 2,099 |
| 2016 | 51 | 114 | 1 | 2,585 |
| 2017 | 67 | 90 | 5 (1) | 2,977 |
| 2018 | 51 | 78 | 5 | 3,525 |
| 2019 | 41 | 88 | 6 | 2,709 |
| 2020 | 52 | 90 | 1 | 2,183 |
| 2021 | 53 | 123 | 0 | 3,465 |
| 2022 | 60 | 152 | 0 | 2,288 |
| 2023 | 52 | 87 | 6 | 2,337 |
| 2024 | 82 | 90 | 3 | 2,187 |
| 2025 | 83 | 90 | 0 | 2,720 |
| 2026 | 57 | 90 | 2 | — |
What is it indicated for?
The Lumenis Family of Intense Pulsed-Light (IPL) systems and combination IPL/Nd:YAG laser systems (and the delivery accessories that are used with them to deliver light and/or laser energy) are indicated for use in surgical, aesthetic and cosmetic applications requiring selective photothermolysis (photocoagulation or coagulation) $d hemostasis of soft tissue in the medical specialties of general and plastic surgery, and dermatology as follows: Intense…
Read the full statement (356 words)
The Lumenis Family of Intense Pulsed-Light (IPL) systems and combination IPL/Nd:YAG laser systems (and the delivery accessories that are used with them to deliver light and/or laser energy) are indicated for use in surgical, aesthetic and cosmetic applications requiring selective photothermolysis (photocoagulation or coagulation) $d hemostasis of soft tissue in the medical specialties of general and plastic surgery, and dermatology as follows:
Intense Pulsed Light Energy/Wavelengths (515 - 1200 nm):
* The treatment of tattoos and benign pigmented epidermal and cutaneous lesions including warts, scars and striae;
* The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations;
* The removal of unwanted hair from all skin types, and to effect stable long-term, or permanent*, hair reduction in skin types I-VI through selective targeting of melanin in hair follicles;
* Permanent hair reduction is defined as a long-term stable reduction in the number of hairs regrowing after a treatment regimen.
Nd:YAG Laser Wavelength (1064 nm):
* The coagulation and hemostasis of vascular lesions and soft tissue, including:
* Treatment and clearance of superficial and deep telangiectasias (venulectasias) and reticular veins (0.1 - 4.0 mm diameter) of the leg;
* The non-ablative treatment of facial wrinkles.
The Real Time Chiller is indicated for use in cooling the epidermis at the treatment site prior to, during and after light or laser treatment in general surgery, plastic surgery and dermatology to:
Reduce pain during and/or associated with light or laser treatment (via partial anesthesia from cooling);
Reduce discomfort during and/or associated with light or laser treatment;
Minimize thermal injury, including thermal necrosis, to non-target skin and skin structures during and/or associated with light or laser treatment, thus reducing possible complications such as scabbing, scarring, hyper- and/or hypo pigmentation;
Allow the use of higher light or laser fluences for light or laser treatments (such as for hair removal and the treatment of vascular or pigmented lesions); and
Reduce potential side effects of light or laser treatments (such as for hair removal and the treatment of vascular or pigmented lesions).
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K024093 · printed Nov 3, 2026
Cite this page
510(k) Report. “K024093: Modified Lumenis Family of Intense Pulsed-Light (Ipl) and Combination Ipl Systems and ND:Yag Laser Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K024093
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026