MX 300 Oxygen Monitor

K024155510(k) TraditionalCleared Jul 17, 2003212-day reviewClass II21 CFR 868.1720

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Teledyne Analytical Instruments · CCL Analyzer, Gas, Oxygen, Gaseous-Phase

Cleared on Jul 17, 2003 after a 212-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 of the 18 devices in its family, counting itself, have a Class I recall. 17 later devices descend from it.

Decided
Jul 17, 2003
Review
212 days
Class
Class II
Product code
CCL
Recalls
None
Predicates
0

17 later devices descend from it, 1 citing it directly. 3 of the 18 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2005: 1 descendant cleared2007: 2 descendants cleared2008: 1 descendant cleared2012: 1 descendant cleared2013: 1 descendant cleared2021: 2 descendants cleared, 1 with a Class I recall12025: 3 descendants cleared2015: 1 descendant cleared2016: 1 descendant cleared2019: 2 descendants cleared, 2 with a Class I recall22024: 2 descendants cleared200020052010201520202025
  1. This deviceK024155 MX 300 Oxygen MonitorTeledyne Analytical Instruments · 2003
  2. Descendant · cites it directly · 16 of its ownK051857 Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates · 2005
  3. Descendant · 2 generations on · 12 of its ownK081601 Veo Multigas Monitor for Pocket PCPhasein AB · 2008
  4. Descendant · 3 generations on · 11 of its ownK123043 Irma C02 Model 200101; Irma AX 200601Phasein AB · 2012
  5. Descendant · 3 generations on · 8 of its ownK123144 VIVO 50Ge Healthcare, Breas Medical AB · 2013 · Recalled
  6. Descendant · 4 generations on · 7 of its ownK160481 Vivo 60Breas Medical AB · 2016 · Recalled

Showing 5 of 17 descendants. See all descendants

Descendants cleared per year

2005: 12007: 22008: 12012: 12013: 12015: 12016: 12019: 22021: 22024: 22025: 3
2005high 3 (2025) · low 0 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 17 · See all
  • K051857Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates · 2005 · cites it directly16descendants
  • K081601Veo Multigas Monitor for Pocket PCPhasein AB · 2008 · 2 generations on12descendants
  • K123043Irma C02 Model 200101; Irma AX 200601Phasein AB · 2012 · 3 generations on11descendants
  • K123144VIVO 50Ge Healthcare, Breas Medical AB · 2013 · 3 generations on8descendants
  • K160481Vivo 60Breas Medical AB · 2016 · 4 generations on7descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K024155MX 300 Oxygen MonitorTeledyne Analytical Instruments2003—
+1K051857Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates2005—
+2K081601Veo Multigas Monitor for Pocket PCPhasein AB2008—
+3K123043Irma C02 Model 200101; Irma AX 200601Phasein AB2012—
+3K123144VIVO 50Ge Healthcare, Breas Medical AB20131
+4K160481Vivo 60Breas Medical AB20162

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200720
200810
201210
201310
201510
201610
201922
202121
202420
202530
FIG. 1 — Lineage of K024155, 2003–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCL device

  1. #1 K261389 PRO2 Elite Plus Oxygen Analyzer (PRO2PLUS-1)score 12.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (17)

See all 17

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051857Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates200516

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K181170Trilogy Evo UniversalRespironics, Inc. · 2019 · 5 generations on · ◆ in the 2019 descendants bar of FIG. 112 Class I recalls
  • K193586Vivo 45 LSBreas Medical AB · 2021 · 5 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K181166Trilogy EvoRespironics, Inc. · 2019 · 5 generations on · ◆ in the 2019 descendants bar of FIG. 131 Class I recalls

What does this lineage say?

  • Of its descendants, K051857 (Weissburg Associates, 2005) has gone furthest, with 16 descendants of its own.

How does its category compare?

All CCL devices

CCL Analyzer, Gas, Oxygen, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CCL

2in 2025

2007: 22008: 22011: 12013: 22016: 12018: 12022: 22023: 12025: 22026 (partial year): 1
2007high 2 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCL

Too few CCL 510(k)s in any year since 2007 to give a median.

Recalls per year · CCL

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CCL

2in 2025

2007: 12008: 22009: 22010: 52011: 42012: 52013: 32014: 82015: 52016: 12017: 22018: 12019: 12020: 12021: 32023: 42024: 42025: 2
2007high 8 (2014) · low 0 (2022)2025

MAUDE reports naming product code CCL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—01
20082—02
20090—12
20100—05
20111—04
20120—05
20132—03
20140—08
20150—05
20161—01
20170—02
20181—01
20190—01
20200—01
20210—03
20222—00
20231—04
20240—04
20252—02
20261—0—

What is it indicated for?

The MX300 is intended to continuously measure and display the concentration of oxygen in gas mixtures used in medical applications such as anesthesia, respiratory therapy, and is intended for adult, pediatric and neonatal populations.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K024155: MX 300 Oxygen Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K024155

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026