Veo Multigas Monitor for Pocket PC, Model 400221

K051857510(k) TraditionalCleared Sep 15, 200569-day reviewClass II21 CFR 868.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Weissburg Associates · CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase

Cleared on Sep 15, 2005 as substantially equivalent to K963327 (Novametrix Medical Systems, Inc., 1996) and 3 other predicates after a 69-day review. Its family tree reaches back 2 generations to 1994. 3 of the 23 devices in its family, counting itself, have a Class I recall. 16 later devices descend from it.

Decided
Sep 15, 2005
Review
69 days
Class
Class II
Product code
CCK
Recalls
None
Predicates
4

Its longest line of descent runs back 2 generations to K935370 (1994). 6 ancestors in all. 16 later devices descend from it, 2 citing it directly. 3 of the 23 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2003: 1 other ancestor1996: 1 other ancestor2000: 1 other ancestor2007: 2 descendants cleared2008: 1 descendant cleared2012: 1 descendant cleared2013: 1 descendant cleared2021: 2 descendants cleared, 1 with a Class I recall12025: 3 descendants cleared2015: 1 descendant cleared2016: 1 descendant cleared2019: 2 descendants cleared, 2 with a Class I recall22024: 2 descendants clearedK935370 · Miniox IA Oxygen Analyzer · Minesafety Appliances Co. · 1994K973282 · Handi Oxygen Analyzer · Ceramatec, Inc. · 19981990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 4 descendants4 generations forward: 3 descendants, 3 with a Class I recall35 generations forward: 4 descendants K973282 · Handi Oxygen Analyzer · Ceramatec, Inc. · 1998K935370 · Miniox IA Oxygen Analyzer · Minesafety Appliances Co. · 19940+5
  1. Root · 2 generations backK935370 Miniox IA Oxygen AnalyzerMinesafety Appliances Co. · 1994
  2. 1 generation backK973282 Handi Oxygen AnalyzerCeramatec, Inc. · 1998
  3. This deviceK051857 Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates · 2005
  4. Descendant · cites it directly · 12 of its ownK081601 Veo Multigas Monitor for Pocket PCPhasein AB · 2008
  5. Descendant · 2 generations on · 11 of its ownK123043 Irma C02 Model 200101; Irma AX 200601Phasein AB · 2012
  6. Descendant · 2 generations on · 8 of its ownK123144 VIVO 50Ge Healthcare, Breas Medical AB · 2013 · Recalled
  7. Descendant · 3 generations on · 7 of its ownK160481 Vivo 60Breas Medical AB · 2016 · Recalled
  8. Descendant · 4 generations on · 5 of its ownK181166 Trilogy EvoRespironics, Inc. · 2019 · Recalled (Class I)

Showing 5 of 16 descendants. See all descendants

Descendants cleared per year

2007: 22008: 12012: 12013: 12015: 12016: 12019: 22021: 22024: 22025: 3
2007high 3 (2025) · low 0 (2009)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 16 · See all
  • K081601Veo Multigas Monitor for Pocket PCPhasein AB · 2008 · cites it directly12descendants
  • K123043Irma C02 Model 200101; Irma AX 200601Phasein AB · 2012 · 2 generations on11descendants
  • K123144VIVO 50Ge Healthcare, Breas Medical AB · 2013 · 2 generations on8descendants
  • K160481Vivo 60Breas Medical AB · 2016 · 3 generations on7descendants
  • K181166Trilogy EvoRespironics, Inc. · 2019 · 4 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K935370Miniox IA Oxygen AnalyzerMinesafety Appliances Co.1994—
−1K973282Handi Oxygen AnalyzerCeramatec, Inc.1998—
0 (this device)K051857Veo Multigas Monitor for Pocket PC, Model 400221Weissburg Associates2005—
+1K081601Veo Multigas Monitor for Pocket PCPhasein AB2008—
+2K123043Irma C02 Model 200101; Irma AX 200601Phasein AB2012—
+2K123144VIVO 50Ge Healthcare, Breas Medical AB20131
+3K160481Vivo 60Breas Medical AB20162
+4K181166Trilogy EvoRespironics, Inc.2019Class I

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200010
200310
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200720
200810
201210
201310
201510
201610
201922
202121
202420
202530
FIG. 1 — Lineage of K051857, 1994–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCK device

  1. #1 K253030 Capnostream™35 Portable Respiratory Monitor…score 15.8 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K963327Tidal Wave Carbon Dioxide Monitor, Model 610
Summary page 1
…CCK) b. Oxygen gas analyzer (21 CFR 868.1720, Product Code CCL) 7. Substantially equivalent to: a. Tidal Wave Model 61 0, Novamnetrix Medical Systems Inc. (K963327) b. MX300 Portable Oxygen Monitor, Teledyne Analytical Instruments (K024155) c. S/5 Multigas Monitor, Datex-Ohmeda-GE…
Novametrix Medical Systems, Inc.19964
*K024155MX 300 Oxygen Monitor
Summary page 1
…tially equivalent to: a. Tidal Wave Model 61 0, Novamnetrix Medical Systems Inc. (K963327) b. MX300 Portable Oxygen Monitor, Teledyne Analytical Instruments (K024155) c. S/5 Multigas Monitor, Datex-Ohmeda-GE (K051092) d. Handi, Ceramatec, Inc (K973282) 8. Device description: The VEO…
Teledyne Analytical Instruments2003—
*K051092Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx) E-Caiovx, E-Caiov…
Summary page 1
…amnetrix Medical Systems Inc. (K963327) b. MX300 Portable Oxygen Monitor, Teledyne Analytical Instruments (K024155) c. S/5 Multigas Monitor, Datex-Ohmeda-GE (K051092) d. Handi, Ceramatec, Inc (K973282) 8. Device description: The VEO Multigas Monitor for Pocket PC combines a miniature m…
GE Healthcare20052
*K973282Handi Oxygen Analyzer
Summary page 1
…b. MX300 Portable Oxygen Monitor, Teledyne Analytical Instruments (K024155) c. S/5 Multigas Monitor, Datex-Ohmeda-GE (K051092) d. Handi, Ceramatec, Inc (K973282) 8. Device description: The VEO Multigas Monitor for Pocket PC combines a miniature mainstream infrared gas analysis bench wit…
Ceramatec, Inc.1998—

Also cleared against K963327: 3 other devices →

What descends from it? (16)

See all 16

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K081601Veo Multigas Monitor for Pocket PCPhasein AB200812
K063167Emma Analyzer (Kpa) and (MMHG); Emma Monitor (Kpa) and (MMHG)Phasein AB20072

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K181170Trilogy Evo UniversalRespironics, Inc. · 2019 · 4 generations on · ◆ in the 2019 descendants bar of FIG. 112 Class I recalls
  • K193586Vivo 45 LSBreas Medical AB · 2021 · 4 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K181166Trilogy EvoRespironics, Inc. · 2019 · 4 generations on · ◆ in the 2019 descendants bar of FIG. 131 Class I recalls

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 7.5 years on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K081601 (Phasein AB, 2008) has gone furthest, with 12 descendants of its own.
  • 3 other devices also cite its predicate K963327.

How does its category compare?

All CCK devices

CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CCK

3in 2025

2007: 52008: 32009: 32010: 32011: 22012: 72013: 42014: 92015: 52016: 22017: 52018: 62019: 72020: 42021: 42022: 32023: 42024: 32025: 32026 (partial year): 3
2007high 9 (2014) · low 2 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCK

169in 2025

2007: 56 days median2008: 248 days median2009: 101 days median2010: 125 days median2012: 150 days median2013: 132 days median2014: 166 days median2015: 105 days median2017: 134 days median2018: 296 days median2019: 261 days median2020: 188 days median2021: 227 days median2022: 226 days median2023: 555 days median2024: 592 days median2025: 169 days median2026 (partial year): 224 days median
2007high 592 (2024) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CCK

1in 2022

2008: 12009: 192010: 42011: 142012: 32013: 2, 1 Class I2015: 12018: 52019: 7, 7 Class I2020: 12022: 1
2007high 19 (2009) · low 0 (2007)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · CCK

1,259in 2025

2007: 72008: 202009: 212010: 122011: 182012: 132013: 282014: 512015: 1142016: 882017: 582018: 632019: 1412020: 2,3022021: 2,2722022: 2,4752023: 1,6372024: 1,2162025: 1,259
2007high 2,475 (2022) · low 7 (2007)2025

MAUDE reports naming product code CCK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200755607
20083248120
200931011921
20103125412
20112—1418
20127150313
201341322 (1)28
20149166051
201551051114
20162—088
20175134058
20186296563
201972617 (7)141
2020418812,302
2021422702,272
2022322612,475
2023455501,637
2024359201,216
2025316901,259
202632240—

What is it indicated for?

The VEO Multigas Monitor for Pocket PC is intended to provide monitoring of carbon dioxide and oxygen during anesthesia, recovery and respiratory care. It may be used in the operating suite, intensive care unit, patient room and emergency medicine settings for adult and pediatric patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K051857: Veo Multigas Monitor for Pocket PC, Model 400221.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051857

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026