510(k) · Cleared
ClearedSmith & Nephew Femoral Heads
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Smith & Nephew, Inc. · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Cleared on Feb 26, 2003 after a 61-day review. The FDA summary names no predicate by number.
- Decided
- Feb 26, 2003
- Review
- 61 days
- Class
- Class II
- Product code
- JDI
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDI device
- #1 K253515 Zimmer Biomet OSS™ Orthopedic Salvage System…score 15.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JDI devicesJDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDI
59in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDI
1,644in 2025
MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 26 | 696 |
| 2008 | 5 | 96 | 6 | 810 |
| 2009 | 3 | 65 | 3 | 964 |
| 2010 | 0 | — | 3 | 2,040 |
| 2011 | 2 | — | 5 | 3,160 |
| 2012 | 4 | 167 | 4 | 5,122 |
| 2013 | 3 | 176 | 11 | 5,206 |
| 2014 | 3 | 98 | 3 | 4,968 |
| 2015 | 3 | 190 | 1 | 4,906 |
| 2016 | 4 | 166 | 5 | 3,995 |
| 2017 | 1 | — | 5 | 6,135 |
| 2018 | 1 | — | 1 | 6,728 |
| 2019 | 2 | — | 1 | 7,407 |
| 2020 | 7 | 247 | 77 | 4,015 |
| 2021 | 3 | 162 | 0 | 3,170 |
| 2022 | 3 | 69 | 0 | 1,978 |
| 2023 | 2 | — | 0 | 1,635 |
| 2024 | 3 | 59 | 0 | 1,821 |
| 2025 | 1 | — | 1 | 1,644 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
Total hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma, inflammatory joint disease such as rheumatoid arthritis, or noninflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis; avascular necrosis; traumatic arthritis; slipped capital epiphysis; fused hip; fracture of the…
Read the full statement (129 words)
Total hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma, inflammatory joint disease such as rheumatoid arthritis, or noninflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis; avascular necrosis; traumatic arthritis; slipped capital epiphysis; fused hip; fracture of the pelvis; diastrophic variant; old, remote osteomyelitis with an extended drainage-free period; nonunion; femoral neck fracture and trochanteric fractures of the proximal femur with heads involvement that are unmanageable using other techniques; femoral osteotomy, or Girdlestone resection; fracture dislocation of the hip; and correction of deformity. The Oxinium Femoral Heads are for single use only and can be used as part of cemented or uncemented total hip arthroplasty.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K024340 · printed Nov 6, 2026
Cite this page
510(k) Report. “K024340: Smith & Nephew Femoral Heads.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K024340
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026