K030429510(k) TraditionalCleared Aug 18, 2003189-day reviewClass II21 CFR 880.6860Recalls 8

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Advanced Sterilization Products · MLR Sterilizer, Chemical

Cleared on Aug 18, 2003 after a 189-day review. The FDA summary names its predicate without a number. 11 later devices descend from it. It has been recalled 8 times.

Decided
Aug 18, 2003
Review
189 days
Class
Class II
Product code
MLR
Recalls
8
Predicates
0

11 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2015: 1 descendant cleared2016: 3 descendants cleared2017: 1 descendant cleared2021: 1 descendant cleared2022: 1 descendant cleared2024: 1 descendant cleared2025: 1 descendant cleared2026: 1 descendant cleared200020052010201520202025
  1. This deviceK030429 Sterrad 200 SterilizerAdvanced Sterilization Products · 2003
  2. Descendant · cites it directly · 10 of its ownK092622 Sterrad 100NX Sterilizer Express CycleAdvanced Sterilization Products · 2011
  3. Descendant · 2 generations on · 9 of its ownK142454 STERRAD NX Sterilizer, STERRAD 100NX SterilizerAdvanced Sterilization Products · 2015 · Recalled
  4. Descendant · 2 generations on · 4 of its ownK160903 STERRAD 100NX Sterilizer with ALLClearTM TechnologyAdvanced Sterilization Products · 2016
  5. Descendant · 3 generations on · 3 of its ownK212174 STERRAD 100NX Sterilizer with ALLClear TechnologyAdvanced Sterilization Products, Inc. · 2021
  6. Descendant · 4 generations on · 2 of its ownK234082 STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™…Advanced Sterilization Products · 2024

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2011: 12015: 12016: 32017: 12021: 12022: 12024: 12025: 12026: 1
2011high 3 (2016) · low 0 (2012)2026

Most influential descendants

Showing 5 of 11 · See all
  • K092622Sterrad 100NX Sterilizer Express CycleAdvanced Sterilization Products · 2011 · cites it directly10descendants
  • K142454STERRAD NX Sterilizer, STERRAD 100NX SterilizerAdvanced Sterilization Products · 2015 · 2 generations on9descendants
  • K160903STERRAD 100NX Sterilizer with ALLClearTM TechnologyAdvanced Sterilization Products · 2016 · 2 generations on4descendants
  • K212174STERRAD 100NX Sterilizer with ALLClear TechnologyAdvanced Sterilization Products, Inc. · 2021 · 3 generations on3descendants
  • K234082STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™ Cycle (10104)…Advanced Sterilization Products · 2024 · 4 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K030429Sterrad 200 SterilizerAdvanced Sterilization Products2003—
+1K092622Sterrad 100NX Sterilizer Express CycleAdvanced Sterilization Products2011—
+2K142454STERRAD NX Sterilizer, STERRAD 100NX SterilizerAdvanced Sterilization Products20152
+2K160903STERRAD 100NX Sterilizer with ALLClearTM TechnologyAdvanced Sterilization Products2016—
+3K212174STERRAD 100NX Sterilizer with ALLClear TechnologyAdvanced Sterilization Products, Inc.2021—
+4K234082STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™ Cycle…Advanced Sterilization Products2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201510
201630
201710
202110
202210
202410
202510
202610
FIG. 1 — Lineage of K030429, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MLR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MLR device

  1. #1 K250802 STERRAD® 100NX Sterilizer with ALLClear™…score 14.0 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—STERRAD 100s Sterilization System
Named without a submission number
—

What descends from it? (11)

See all 11

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092622Sterrad 100NX Sterilizer Express CycleAdvanced Sterilization Products201110

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 4, 2014Class IIZ-0844-2015Nonconforming Material/ComponentAdvanced Sterilization Products is recalling the STERRAD System cassettes because the the leak indicator on the STERRAD System cassettes packaging may not function properly after exposure to hydrogen peroxide.
Sep 18, 2013Class IIZ-0043-2014Under Investigation by firmAdvanced Sterilization Products (ASP) is recalling the STERRAD 200 Sterilization System because it may emit an odor or smell into the surrounding environment that is not typical to normal operating conditions.
Mar 22, 2013Class IIZ-1027-2013Nonconforming Material/ComponentThe recall was initiated because Advanced Sterilization Products (ASP) has determined that the STERRAD 100NX and STERRAD 200 Sterilization Systems may emit an odor or smell into the surrounding environment that is not typical to normal…
Mar 13, 2012Class IIZ-0998-2013Device DesignAdvanced Sterilization Products (ASP) is recalling the STERRAD 200 System Carriage because it can potentially become dislodged when an excessive load is applied.
Jan 23, 2012Not classifiedZ-0741-2012Nonconforming Material/ComponentASP determined that an internal filter in the vacuum pump on the STERRAD 200 System is subject to wear over time.
Feb 25, 2008Not classifiedZ-1630-2008Device DesignOil mist filter fails allowing oil mist to be emitted into the vicinity of the sterilizer, which may result in the release of a mist, "haze," or "smoke."
Nov 12, 2007Not classifiedZ-0844-2008OtherOutdated Compatibility Lists: Recalling firm has decided to discontinue dissemination of Compatible Medical Device Reference Lists and instrument assessment activities
Nov 12, 2007Not classifiedZ-0845-2008Employee errorUser Guide Update: based on user reports about contact with residual hydrogen peroxide from instruments, pouches and trays after sterilization and subsequent light colored residue on these devices after sterilization updated user guidance…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K092622 (Advanced Sterilization Products, 2011) has gone furthest, with 10 descendants of its own.

How does its category compare?

All MLR devices

MLR Sterilizer, Chemical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MLR

1in 2025

2007: 22009: 12011: 62012: 22013: 12014: 22015: 12016: 42017: 22018: 22019: 42021: 22022: 22023: 52024: 32025: 12026 (partial year): 1
2007high 6 (2011) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MLR

216in 2024

2011: 214 days median2016: 183 days median2019: 90 days median2023: 222 days median2024: 216 days median
2007high 222 (2023) · low 90 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MLR

1in 2017

2007: 52008: 82009: 22010: 12011: 22012: 32013: 92014: 32017: 1
2007high 9 (2013) · low 0 (2015)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MLR

46in 2025

2007: 2722008: 5362009: 4332010: 2112011: 342012: 1012013: 5412014: 3992015: 4122016: 2862017: 2792018: 2892019: 2222020: 1742021: 2022022: 1882023: 1402024: 442025: 46
2007high 541 (2013) · low 34 (2011)2025

MAUDE reports naming product code MLR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—5272
20080—8536
20091—2433
20100—1211
20116214234
20122—3101
20131—9541
20142—3399
20151—0412
201641830286
20172—1279
20182—0289
20194900222
20200—0174
20212—0202
20222—0188
202352220140
20243216044
20251—046
20261—0—

What is it indicated for?

The STERRAD® 200 Sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures. Because the cycle operates within a dry environment and at low temperatures, it is especially suitable for instruments sensitive to heat and moisture. The STERRAD® 200 Sterilizer can sterilize instruments which have diffusion-restricted spaces, such as the hinged portion of forceps and scissors. Medical devices with only a single…

Read the full statement (247 words)

The STERRAD® 200 Sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures. Because the cycle operates within a dry environment and at low temperatures, it is especially suitable for instruments sensitive to heat and moisture.

The STERRAD® 200 Sterilizer can sterilize instruments which have diffusion-restricted spaces, such as the hinged portion of forceps and scissors.

Medical devices with only a single stainless steel lumen with the following dimensions can be processed in the STERRAD® 200 Sterilizer.

An inside diameter of 1 mm or larger and a length of 125 mm or shorter*

An inside diameter of 2 mm or larger and a length of 250 mm or shorter*

An inside diameter of 3 mm or larger and a length of 400 mm or shorter

Teflon® and polyethylene lumen instruments with inside diameters of 6 mm or larger and lengths of 310 mm or shorter can be processed in the STERRAD® 200 Sterilizer.

*The validation testing for this lumen size was conducted using a maximum of 12 lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing.

Note: The validation studies for this sterilizer were performed using the STERRAD cycle consisting of a 6-minute 45-second injection phase followed by a 2-minute diffusion phase and a 2-minute plasma phase. The validation studies were performed using a validation load consisting of four instrument trays each weighing 9.12 lbs. (the total weight of the load was 36.48 lbs.).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K030429: Sterrad 200 Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K030429

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026