ClearedNewport E500 Wave Ventilator
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Newport Medical Instruments, Inc. · CBK Ventilator, Continuous, Facility Use
Cleared on Jan 23, 2004 after a 318-day review. The FDA summary names its predicate without a number. 4 later devices descend from it.
- Decided
- Jan 23, 2004
- Review
- 318 days
- Class
- Class II
- Product code
- CBK
- Recalls
- None
- Predicates
- 0
4 later devices descend from it, 3 citing it directly.
- This deviceK030780 Newport E500 Wave VentilatorNewport Medical Instruments, Inc. · 2004
- Descendant · cites it directly · 2 of its ownK061094 Newport E500 Wave VentilatorNewport Medical Instruments, Inc. · 2006
- Descendant · cites it directly · 2 of its ownK053502 Newport E360 VentilatorNewport Medical Instruments, Inc. · 2006 · Recalled
- Descendant · cites it directly · 1 of its ownK101803 Newport E360 VentilatorNewport Medical Instruments, Inc. · 2010
- Descendant · 2 generations on · 0 of its ownK121891 Newport Aura VentilatorNewport Medical Instruments, Inc. · 2012
Most influential descendants
Showing 4 of 4 · See all- K061094Newport E500 Wave VentilatorNewport Medical Instruments, Inc. · 2006 · cites it directly2descendants
- K053502Newport E360 VentilatorNewport Medical Instruments, Inc. · 2006 · cites it directly2descendants
- K101803Newport E360 VentilatorNewport Medical Instruments, Inc. · 2010 · cites it directly1descendant
- K121891Newport Aura VentilatorNewport Medical Instruments, Inc. · 2012 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K030780 | Newport E500 Wave Ventilator | Newport Medical Instruments, Inc. | 2004 | — |
| +1 | K061094 | Newport E500 Wave Ventilator | Newport Medical Instruments, Inc. | 2006 | — |
| +1 | K053502 | Newport E360 Ventilator | Newport Medical Instruments, Inc. | 2006 | 3 |
| +1 | K101803 | Newport E360 Ventilator | Newport Medical Instruments, Inc. | 2010 | — |
| +2 | K121891 | Newport Aura Ventilator | Newport Medical Instruments, Inc. | 2012 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
| 2010 | 1 | 0 |
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CBK device
- #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | E200 Ventilator Named without a submission number | |
| * | — | Siemens Servo Ventilators Named without a submission number |
What descends from it? (4)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K061094 (Newport Medical Instruments, Inc., 2006) has gone furthest, with 2 descendants of its own.
How does its category compare?
All CBK devicesCBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CBK
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · CBK
163in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CBK
14in 2024
Class I (81 since 2007) Class II/III not classified
Adverse event reports per year · CBK
13,991in 2025
MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 11 | 142 | 17 | 1,531 |
| 2008 | 18 | 115 | 23 | 1,933 |
| 2009 | 12 | 122 | 8 | 1,766 |
| 2010 | 14 | 150 | 9 | 1,799 |
| 2011 | 13 | 192 | 12 | 1,877 |
| 2012 | 17 | 207 | 2 (1) | 5,509 |
| 2013 | 5 | 277 | 5 (2) | 7,921 |
| 2014 | 5 | 439 | 5 (4) | 7,600 |
| 2015 | 7 | 266 | 6 (4) | 11,876 |
| 2016 | 4 | 323 | 4 (1) | 16,056 |
| 2017 | 6 | 280 | 1 | 14,451 |
| 2018 | 4 | 183 | 3 (3) | 9,849 |
| 2019 | 8 | 435 | 14 (13) | 9,100 |
| 2020 | 5 | 176 | 4 | 11,096 |
| 2021 | 6 | 267 | 21 (19) | 13,322 |
| 2022 | 0 | — | 8 (4) | 15,974 |
| 2023 | 5 | 309 | 4 (3) | 24,928 |
| 2024 | 9 | 203 | 14 (14) | 20,336 |
| 2025 | 4 | 163 | 0 | 13,991 |
| 2026 | 3 | 235 | 15 (13) | — |
What is it indicated for?
The e500 Ventilator is intended to provide continuous (ET tube) or noncontinuous (mask) ventilatory support and monitoring for infant, pedatric and adult patients with a tidal volume of > 20 mL. The device is prescription use only. The intended environments include hospital, hospitaltype and intra-hospital transport environments. Hospital use typically includes general care floors, operating rooms, special procedure areas, and intensive and critical care…
Read the full statement (99 words)
The e500 Ventilator is intended to provide continuous (ET tube) or noncontinuous (mask) ventilatory support and monitoring for infant, pedatric and adult patients with a tidal volume of > 20 mL. The device is prescription use only.
The intended environments include hospital, hospitaltype and intra-hospital transport environments. Hospital use typically includes general care floors, operating rooms, special procedure areas, and intensive and critical care areas within the hospital. Hospital-type use includes facilities such as or similar to surgicenters, sub-acute centers, and special nursing facilities outside of the hospital. Intra-hospital transport includes patient transport within the hospital or hospital-type facility.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K030780 · printed Nov 4, 2026
Cite this page
510(k) Report. “K030780: Newport E500 Wave Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K030780
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026