510(k) Report

510(k) · Cleared

Cleared

Newport Aura Ventilator

K121891510(k) TraditionalCleared Nov 9, 2012133-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Newport Medical Instruments, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Nov 9, 2012 as substantially equivalent to K090888 (Newport Medical Instruments, Inc., 2009) and 3 other predicates after a 133-day review. Its family tree reaches back 13 generations to 1991. 10 of the 95 devices in its family, counting itself, have a Class I recall.

Decided
Nov 9, 2012
Review
133 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
4

Its longest line of descent runs back 13 generations to K902859 (1991). 94 ancestors in all, the oldest K841279 (1984). No later device cites it as a predicate yet. 10 of the 95 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2010: 1 other ancestor2006: 3 other ancestors2008: 1 other ancestor2007: 1 other ancestor, 1 with a Class I recall12005: 3 other ancestors2004: 7 other ancestors, 1 with a Class I recall12003: 4 other ancestors, 1 with a Class I recall12001: 6 other ancestors2000: 5 other ancestors, 1 with a Class I recall11999: 6 other ancestors1998: 13 other ancestors, 3 with a Class I recall32002: 4 other ancestors1996: 3 other ancestors1995: 3 other ancestors1997: 3 other ancestors1991: 4 other ancestors1990: 6 other ancestors1984: 1 other ancestor1994: 3 other ancestors1993: 1 other ancestor1992: 2 other ancestors1988: 1 other ancestorK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalled×2: 2 generations cleared close together, K052554 (2005), K053270 (2006) K061627 · Modification to I Vent 201 · Versamed Medical Systems, Inc. · 2006K063404 · Servo-I Ventilator System, Models 64, 87 and 800 · Maquet Critical Care AB · 2007K073694 · Ivent 2001 Mri Conditional · Versamed Medical Systems, Inc. · 2008K090888 · Newport HT70 Family of Ventilators · Newport Medical Instruments, Inc. · 2009 · Class I recallK111146 · Newport HT70 Ventilator · Newport Medical Instruments, Inc. · 2011 · Class I recall1980198519901995200020052010
Other ancestors, by generation 1 generation back: 2 other ancestors2 generations back: 17 other ancestors, 1 with a Class I recall13 generations back: 9 other ancestors, 2 with a Class I recall24 generations back: 20 other ancestors, 3 with a Class I recall35 generations back: 19 other ancestors, 1 with a Class I recall16 generations back: 12 other ancestors7 generations back: 2 other ancestors K111146 · Newport HT70 Ventilator · Newport Medical Instruments, Inc. · 2011 · Class I recallK090888 · Newport HT70 Family of Ventilators · Newport Medical Instruments, Inc. · 2009 · Class I recallK073694 · Ivent 2001 Mri Conditional · Versamed Medical Systems, Inc. · 2008K063404 · Servo-I Ventilator System, Models 64, 87 and 800 · Maquet Critical Care AB · 2007K061627 · Modification to I Vent 201 · Versamed Medical Systems, Inc. · 2006K053270 · IVENT 201 · Versamed Medical Systems, Inc. · 2006K052554 · Modification to: Ivent 201 Portable Ventilator · Versamed Medical Systems, Inc. · 2005K032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalledK013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled−10−50
  1. Root · 13 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 9 generations between
  3. 3 generations backK073694 Ivent 2001 Mri ConditionalVersamed Medical Systems, Inc. · 2008
  4. 2 generations backK090888 Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · Recalled (Class I)
  5. 1 generation backK111146 Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · Recalled (Class I)
  6. This deviceK121891 Newport Aura VentilatorNewport Medical Instruments, Inc. · 2012
Show all 13 generations
  1. Root · 13 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 12 generations backK960010 Servo Ventilator 300 Computer InterfaceSiemens Elema AB · 1996
  3. 11 generations backK970839 Servo Ventilator 300ASiemens Elema AB · 1997 · Recalled
  4. 10 generations backK992788 Bear Cub 750 PSVBear Medical Systems, Inc. · 1999
  5. 9 generations backK013642 AVEABird Products Corp. · 2002 · Recalled (Class I)
  6. 8 generations backK032451 Bird Tbird Vela VentilatorBird Products Corp. · 2004 · Recalled
  7. 7 generations backK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  8. 6 generations backK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  9. 5 generations backK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  10. 4 generations backK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  11. 3 generations backK073694 Ivent 2001 Mri ConditionalVersamed Medical Systems, Inc. · 2008
  12. 2 generations backK090888 Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · Recalled (Class I)
  13. 1 generation backK111146 Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · Recalled (Class I)
  14. This deviceK121891 Newport Aura VentilatorNewport Medical Instruments, Inc. · 2012

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13K902859Servo Ventilator 300Siemens Life Support Systems19913
−12K960010Servo Ventilator 300 Computer InterfaceSiemens Elema AB1996—
−11K970839Servo Ventilator 300ASiemens Elema AB19974
−10K992788Bear Cub 750 PSVBear Medical Systems, Inc.1999—
−9K013642AVEABird Products Corp.2002Class I
−8K032451Bird Tbird Vela VentilatorBird Products Corp.20041
−7K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
−6K053270IVENT 201Versamed Medical Systems, Inc.2006—
−5K061627Modification to I Vent 201Versamed Medical Systems, Inc.2006—
−4K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—
−3K073694Ivent 2001 Mri ConditionalVersamed Medical Systems, Inc.2008—
−2K090888Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc.2009Class I
−1K111146Newport HT70 VentilatorNewport Medical Instruments, Inc.2011Class I
0 (this device)K121891Newport Aura VentilatorNewport Medical Instruments, Inc.2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198410
198810
199060
199140
199220
199310
199430
199530
199630
199730
1998133
199960
200051
200160
200240
200341
200471
200530
200630
200711
200810
201010
FIG. 1 — Lineage of K121891, 1991–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

10 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090888Newport HT70 Family of Ventilators
Summary page 1
…cate Devices The AURA is substantially equivalent to the following legally marketed predicate devices: * NEWPORT HT7O® Ventilator cleared under K090888, Kil1146- * NEWPORT e360 cleared under K053502, K101 803 IV. Device Description The AURA Ventil…
Newport Medical Instruments, Inc.2009Class I
*K111146Newport HT70 VentilatorNewport Medical Instruments, Inc.2011Class I
*K053502Newport E360 Ventilator
Summary page 1
…the following legally marketed predicate devices: * NEWPORT HT7O® Ventilator cleared under K090888, Kil1146- * NEWPORT e360 cleared under K053502, K101 803 IV. Device Description The AURA Ventilator provides ventilatory support for infant, pediatric and adu…
Newport Medical Instruments, Inc.20063
*K101803Newport E360 Ventilator
Summary page 1
…wing legally marketed predicate devices: * NEWPORT HT7O® Ventilator cleared under K090888, Kil1146- * NEWPORT e360 cleared under K053502, K101 803 IV. Device Description The AURA Ventilator provides ventilatory support for infant, pediatric and adult patient…
Newport Medical Instruments, Inc.2010—

Also cleared against K090888: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (10 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K111146Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · Direct predicate · ◆ on the line of descent in FIG. 14 Class I recalls
  • K090888Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · Direct predicate · ◆ on the line of descent in FIG. 13 Class I recalls
  • K070594Palmtop Ventilator, Models PTV-8, PTV-10Pulmonetic Systems, Inc. · 2007 · 2 generations back · ◆ in the 2007 ancestors bar of FIG. 12 Class I recalls
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 3 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K984535Puritan-Bennett 840 Ventilatory System with Bilevel OptionPuritan Bennett Corp. · 1998 · 3 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K023366Datex-Ohmeda 7900 Ventilator EnhancementsDatex-Ohmeda, Inc. · 2003 · 4 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
  • K013642AVEABird Products Corp. · 2002 · 4 generations back · ◆ on the line of descent in FIG. 113 Class I recalls
  • K981072Esprit VentilatorRespironics, Inc. · 1998 · 4 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · 4 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K001646Puritan-Bennett 840 Ventilator System with Neomode OptionPuritan Bennett Corp. · 2000 · 5 generations back · ◆ in the 2000 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 21 years and passes through 7 companies; a new generation was cleared every 1.5 years on median.
  • 35 of the 94 ancestors have a recall of any class; 10 have a Class I recall.
  • 1 other device also cites its predicate K090888.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The AURA Family of Ventilators is intended to provide continuous or intermittent positive pressure mechanical ventilatory support through invasive or non-invasive interfaces to individuals that require such medical care. Specifically, the AURA Family of Ventilators is applicable for infant, pediatric and adult patients greater than or equal to 5 kg (11 lbs.).

The AURA ventilator is a restricted medical device intended for use by qualified, trained, personnel under the direction of a physician.

The AURA ventilator is suitable for use in hospital, sub-acute, emergency room, and home care environments, as well as for transport and emergency response applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121891: Newport Aura Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K121891

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026