Polaris 95000-a Bedside/Transport Monitor

K031124510(k) TraditionalCleared Dec 4, 2003240-day reviewClass II21 CFR 870.1025Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Datex-Ohmeda, Inc. · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Dec 4, 2003 as substantially equivalent to K013046 (Spacelabs Medical, Inc., 2002) and 1 other predicate after a 240-day review. Its family tree reaches back 1 generation to 1994. It has been recalled 2 times.

Decided
Dec 4, 2003
Review
240 days
Class
Class II
Product code
MHX
Recalls
2
Predicates
2

Its longest line of descent runs back 1 generation to K941165 (1994). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2002: 1 other ancestorReference device: K963380 · CO 2 Smo Plus · Novametrix Medical Systems, Inc. · 1997 · recalledK941165 · Comet Capnograph Module · Spacelabs, Inc. · 19941990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor K941165 · Comet Capnograph Module · Spacelabs, Inc. · 19940
  1. Root · 1 generation backK941165 Comet Capnograph ModuleSpacelabs, Inc. · 1994
  2. This deviceK031124 Polaris 95000-a Bedside/Transport MonitorDatex-Ohmeda, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K941165Comet Capnograph ModuleSpacelabs, Inc.1994—
0 (this device)K031124Polaris 95000-a Bedside/Transport MonitorDatex-Ohmeda, Inc.2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
FIG. 1 — Lineage of K031124, 1994–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013046Cosmos System
Summary page 1
…Classification: Class III Classification Classification Panel: Cardiovascular Devices P Spacelabs 95000 Bedside/Transport Monitor, K013046 (cleared 08/02) Predicate · Spacelabs Comet Capnograph Module (90516), K941165 (cleared 10/94) Devices *…
Spacelabs Medical, Inc.2002—
*K941165Comet Capnograph Module
Summary page 1
…ardiovascular Devices P Spacelabs 95000 Bedside/Transport Monitor, K013046 (cleared 08/02) Predicate · Spacelabs Comet Capnograph Module (90516), K941165 (cleared 10/94) Devices * Novametrix CO 2SMO Plus Monitor (8100), K963380 (cleared 01/97) Performance FDA…
Spacelabs, Inc.1994—
†K963380CO 2 Smo PlusNovametrix Medical Systems, Inc.19973

Also cleared against K013046: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 12, 2011Not classifiedZ-2573-2011Software designCapnography Module, Model 91517, resets 20 seconds after power failure, instead of after three minutes as specified. This reset clears the RAM and the module returns to default settings.
Jul 20, 2005Not classifiedZ-0517-06OtherThe transducer used to compensate for pressure changes was mounted backwards on the printed circuit board assembly. The module will not compensate for pressure changes and CO2 readings will be inaccurate at higher altitudes.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K013046.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The Model 95000-A Bedside/Transport Monitor is used at the patient's bedside to actively acquire, analyze, monitor and display a variety of clinical parameters (in clinically relevant formats) for adults, pediatric or neonatal patients. The Model 95000-A Bedside/Transport Monitor is designed for use by a healthcare professional in a hospital, healthcare facility (ie, clinic), or intra-hospital transport. This product is not designed for home use or for…

Read the full statement (249 words)

The Model 95000-A Bedside/Transport Monitor is used at the patient's bedside to actively acquire, analyze, monitor and display a variety of clinical parameters (in clinically relevant formats) for adults, pediatric or neonatal patients.

The Model 95000-A Bedside/Transport Monitor is designed for use by a healthcare professional in a hospital, healthcare facility (ie, clinic), or intra-hospital transport. This product is not designed for home use or for use in transport vehicles.

The Model 95000-A Bedside/Transport Monitor supports product configurations with almost any combination of clinical parameters that provide the following:

* A means for continuous monitoring of:

* Electrocardiographic signals in order to detect:

* Normal cardiac rhythms, including life-threatening events such as high and low heart rates, asystole and ventricular fibrillation.

* (Adult patients only) Additional abnormal cardiac rhythms, such as ventricular runs and tachycardia, and ST segment deviations.

* Respiratory effort in order to detect abnormal respiration events such as high and low respiration rates and episodes or apnea.

* Invasive blood pressure in order to detect abnormal events such as high and low blood pressure.

* Pulse oxygen saturation in order to detect desaturation due to abnormal pulmonary or circulatory functions.

* Temperature in order to detect abnormal events such as high and low temperatures.

- Carbon dioxide.

* Oxygen.

· A means for episodic monitoring of:

* Non-invasive blood pressure signals to detect abnormal events such as high and low blood pressure.

* (Adult patients only) Various hemodynamic values to detect abnormal cardiac flow (CO) values.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K031124: Polaris 95000-a Bedside/Transport Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K031124

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026