510(k) Report

510(k) · Cleared

Recalled · Class II · 2016

External Drainage Set

K032817510(k) SpecialCleared Oct 6, 200326-day reviewClass II21 CFR 882.5550Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Neurosciences Implants S.A. · JXG Shunt, Central Nervous System And Components

Cleared on Oct 6, 2003 as substantially equivalent to K910853 (Cordis Corp., 1991) after a 26-day review. Its family tree reaches back 1 generation to 1991. 2 later devices descend from it. It has been recalled once.

Decided
Oct 6, 2003
Review
26 days
Class
Class II
Product code
JXG
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K910853 (1991). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2013: 1 descendant cleared2015: 1 descendant clearedK910853 · Graduated Cylinder of External Drainage Set · Cordis Corp. · 1991 · recalled1990200020102020
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K910853 · Graduated Cylinder of External Drainage Set · Cordis Corp. · 1991 · recalled0
  1. Root · 1 generation backK910853 Graduated Cylinder of External Drainage SetCordis Corp. · 1991 · Recalled
  2. This deviceK032817 External Drainage SetIntegra Neurosciences Implants S.A. · 2003
  3. Descendant · cites it directly · 1 of its ownK121248 Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF…Moller Medical GmbH · 2013
  4. Descendant · 2 generations on · 0 of its ownK150898 LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015

Most influential descendants

Showing 2 of 2 · See all
  • K121248Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set (2000MM)…Moller Medical GmbH · 2013 · cites it directly1descendant
  • K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K910853Graduated Cylinder of External Drainage SetCordis Corp.19911
0 (this device)K032817External Drainage SetIntegra Neurosciences Implants S.A.2003—
+1K121248Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set…Moller Medical GmbH2013—
+2K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201510
FIG. 1 — Lineage of K032817, 1991–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K910853Graduated Cylinder of External Drainage Set
Summary page 1
…ly equivalent in function and intended use to the Unmodified External Drainage Set which has been cleared to market under Preniarket Notification 5 10(k) K910853. D- I Integra NeuroSciences Implants S.A. Special 5 10(k): Device…
Cordis Corp.19911

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121248Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set (2000MM)…Moller Medical GmbH20131

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 23, 2016Class IIZ-2910-2016Process controlDuring final sampling inspection, one of the lots was discovered with a total incomplete packaging seal of the sterile product.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K121248 (Moller Medical GmbH, 2013) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—

What is it indicated for?

The drainage sets are intended for cerebrospinal fluid (CSF) drainage, sampling and collection.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032817: External Drainage Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K032817

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026