510(k) Report

510(k) · Cleared

Cleared

Codman Libertís Shunt Catheter with Bactiseal and Endexo Technology

K243531510(k) TraditionalCleared Aug 8, 2025267-day reviewClass II21 CFR 882.5550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Lifesciences Production Corporation · JXG Shunt, Central Nervous System And Components

Cleared on Aug 8, 2025 as substantially equivalent to K233445 (Integra Lifesciences Production Corporation, 2024) after a 267-day review. Its family tree reaches back 8 generations to 1995.

Decided
Aug 8, 2025
Review
267 days
Class
Class II
Product code
JXG
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K944222 (1995). 18 ancestors in all, the oldest K902783 (1990). No later device cites it as a predicate yet.

  1. Root · 8 generations backK944222 Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc. · 1995
  2. 7 generations backK973774 Codman Hakim Micro Precision ValveJohnson & Johnson Professionals, Inc. · 1997
  3. 6 generations backK980778 Hakim Micro Programmable Valve SystemJohnson & Johnson Professionals, Inc. · 1998
  4. 5 generations backK020667 Codman Hakim Shunt SystemsCodman & Shurtleff, Inc. · 2002
  5. 4 generations backK053350 Modification to Codman Hakim Shunt SystemsCodman & Shurtleff, Inc. · 2006
  6. 3 generations backK122118 Hakim Programmable and Precision Valve Shunt SystemCodman & Shurtleff, Inc. · 2012
  7. 2 generations backK172022 CODMAN Hydrocephalus Valves, Catheters & Accessories (Bundled)Codman & Shurtleff, Inc. · 2017 · Recalled
  8. 1 generation backK233445 Bactiseal Catheters; Bactiseal Barium Striped Catheters; Bactiseal…Integra Lifesciences Production Corporation · 2024
  9. This deviceK243531 Codman Libertís Shunt Catheter with Bactiseal and Endexo TechnologyIntegra Lifesciences Production Corporation · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K944222Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc.1995—
−7K973774Codman Hakim Micro Precision ValveJohnson & Johnson Professionals, Inc.1997—
−6K980778Hakim Micro Programmable Valve SystemJohnson & Johnson Professionals, Inc.1998—
−5K020667Codman Hakim Shunt SystemsCodman & Shurtleff, Inc.2002—
−4K053350Modification to Codman Hakim Shunt SystemsCodman & Shurtleff, Inc.2006—
−3K122118Hakim Programmable and Precision Valve Shunt SystemCodman & Shurtleff, Inc.2012—
−2K172022CODMAN Hydrocephalus Valves, Catheters & Accessories (Bundled)Codman & Shurtleff, Inc.20171
−1K233445Bactiseal Catheters; Bactiseal Barium Striped Catheters; Bactiseal Endoscopic…Integra Lifesciences Production Corporation2024—
0 (this device)K243531Codman Libertís Shunt Catheter with Bactiseal and Endexo TechnologyIntegra Lifesciences Production Corporation2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199410
199810
200010
200110
200210
200310
200410
201120
FIG. 1 — Lineage of K243531, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K251598 Intellidropscore 11.7 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K233445Bactiseal Catheters; Bactiseal Barium Striped Catheters; Bactiseal Endoscopic…
Summary page 5
…JXG 807.92(a) (3) Predicate Information Predicate Device Codman® Bactiseal® Shunt Catheter: K233445 807.92(a) (4) Device Description The Libertís™ Shunt Catheter includes a ventricular and distal (peritoneal) drainage catheter…
Integra Lifesciences Production Corporation2024—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 3 companies; a new generation was cleared every 3.8 years on median.
  • 4 of the 18 ancestors have a recall of any class.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—

What is it indicated for?

For use in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K243531: Codman Libertís Shunt Catheter with Bactiseal and Endexo Technology.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K243531

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026