510(k) · Cleared
ClearedMedicheart, Model Release 1
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medicsight · JAK System, X-Ray, Tomography, Computed
Cleared on Nov 10, 2003 as substantially equivalent to K020929 (GE Medical Systems, 2002) and 2 other predicates after a 61-day review. Its family tree reaches back 4 generations to 1995.
- Decided
- Nov 10, 2003
- Review
- 61 days
- Class
- Class II
- Product code
- JAK
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 4 generations to K945512 (1995). 8 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK945512 HRSW Option for CT Twin FlashElscint, Inc. · 1995
- 3 generations backK970980 Cardiac Scoring for CT ScannersElscint, Inc. · 1997
- 2 generations backK982004 CT Coronary Artery Calcification Scoring (Cacs) Option for Advantage…General Electric Co. · 1998
- 1 generation backK013146 Viatronic V3D Calcium ScoringViatronix, Inc. · 2001
- This deviceK032823 Medicheart, Model Release 1Medicsight · 2003
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K945512 | HRSW Option for CT Twin Flash | Elscint, Inc. | 1995 | — |
| −3 | K970980 | Cardiac Scoring for CT Scanners | Elscint, Inc. | 1997 | — |
| −2 | K982004 | CT Coronary Artery Calcification Scoring (Cacs) Option for Advantage Windows | General Electric Co. | 1998 | — |
| −1 | K013146 | Viatronic V3D Calcium Scoring | Viatronix, Inc. | 2001 | — |
| 0 (this device) | K032823 | Medicheart, Model Release 1 | Medicsight | 2003 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2002 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K020929 | Smartscore 3.5; Smartscore 4.0; Smartscore 4.5 | 2002 |
| * | K013146 | Viatronic V3D Calcium ScoringSummary page 1…510(k) No. G E Medical Systems SMARTSCORE 3.5; 4.0; 4.5 KO20929 V IA.I'RON IX V3D CALCIUM SCORING K 0 1 3 1 46 VOXAR CALCIUM SCORING PRODUCT KO20 140 rnedtcsight Device Descript… | 2001 |
| * | K020140 | Voxar's Calcium Scoring Product | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 4 companies; a new generation was cleared every 2.2 years on median.
- None of the 8 ancestors has a recall.
- 4 other devices also cite its predicate K020929.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
MedicHeart 1 is a PC-based, stand-alone, non-invasive, image analysis software application intended to assist radiologists and other clinicians in the identification and quantification of coronary calcified plaques in the coronary arteries from CT image data. This quantification allows for evaluation of the progression or regression of calcified plaques in coronary arteries over time.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032823 · printed Nov 4, 2026
Cite this page
510(k) Report. “K032823: Medicheart, Model Release 1.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K032823
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026