510(k) Report

510(k) · Cleared

Cleared

FCT iStream Phase 2

K253836510(k) TraditionalCleared Sep 4, 2026277-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fujifilm Corporation · JAK System, X-Ray, Tomography, Computed

Cleared on Sep 4, 2026 as substantially equivalent to K250370 (Fujifilm Corporation, 2025) after a 277-day review. Its family tree reaches back 14 generations to 2003.

Decided
Sep 4, 2026
Review
277 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
1

Its longest line of descent runs back 14 generations to K031469 (2003). 15 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2015: 1 other ancestorReference device: K233583 · FCT iSTREAM Phase 1 · FUJIFILM Healthcare Americas Corporation · 2024K031469 · Aquilion Super 4 Multislice CT Scanner, Model TSX-101A/7 · Toshiba America Medical Systems, In.C · 2003 · recalledK033418 · TSX-101A/a and TSX-101A/C Aquilion Multislice CT Scanners · Toshiba America Medical Systems, In.C · 2003 · recalledK051833 · TSX-101A/H Aquilion 64 SP CT Scanner; TSX-101A/I Aquilion 32 SP CT Scanner · Toshiba America Medical Systems, In.C · 2005K080211 · Model TSX-101A/H/I Aquilion 32/64 SP CT System · Toshiba America Medical Systems, In.C · 2008 · recalledK101888 · Scenaria Whole-Body X-Ray CT System · Hitachi Medical Systems America, Inc. · 2011 · recalledK123509 · Scenaria Phase 2 Whole-Body X-Ray CT System · Hitachi Medical Systems America, Inc. · 2013K161748 · SUPRIA w/guideShot Option · Hitachi Medical Systems America, Inc. · 2016K163528 · HITACHI Supria Whole-body X-ray CT System Phase 3 · Hitachi Medical Systems America, Inc. · 2017K171738 · Supria True64 · Hitachi Healthcare Americas Corporation · 2017K190841 · SCENARIA View · Hitachi Healthcare Americas · 2019K200498 · SCENARIA View · Hitachi Healthcare Americas · 2020K213829 · SCENARIA View · Fujifilm Healthcare Corporation · 2022 · recalledK231574 · Scenaria View 4.2 · FUJIFILM Healthcare Americas Corporation · 2023K250370 · SCENARIA View Phase 5.0 · Fujifilm Corporation · 2025200020052010201520202025
  1. Root · 14 generations backK031469 Aquilion Super 4 Multislice CT Scanner, Model TSX-101A/7Toshiba America Medical Systems, In.C · 2003 · Recalled
  2. 10 generations between
  3. 3 generations backK213829 SCENARIA ViewFujifilm Healthcare Corporation · 2022 · Recalled
  4. 2 generations backK231574 Scenaria View 4.2FUJIFILM Healthcare Americas Corporation · 2023
  5. 1 generation backK250370 SCENARIA View Phase 5.0Fujifilm Corporation · 2025
  6. This deviceK253836 FCT iStream Phase 2Fujifilm Corporation · 2026
Show all 14 generations
  1. Root · 14 generations backK031469 Aquilion Super 4 Multislice CT Scanner, Model TSX-101A/7Toshiba America Medical Systems, In.C · 2003 · Recalled
  2. 13 generations backK033418 TSX-101A/a and TSX-101A/C Aquilion Multislice CT ScannersToshiba America Medical Systems, In.C · 2003 · Recalled
  3. 12 generations backK051833 TSX-101A/H Aquilion 64 SP CT Scanner; TSX-101A/I Aquilion 32 SP CT…Toshiba America Medical Systems, In.C · 2005
  4. 11 generations backK080211 Model TSX-101A/H/I Aquilion 32/64 SP CT SystemToshiba America Medical Systems, In.C · 2008 · Recalled
  5. 10 generations backK101888 Scenaria Whole-Body X-Ray CT SystemHitachi Medical Systems America, Inc. · 2011 · Recalled
  6. 9 generations backK123509 Scenaria Phase 2 Whole-Body X-Ray CT SystemHitachi Medical Systems America, Inc. · 2013
  7. 8 generations backK161748 SUPRIA w/guideShot OptionHitachi Medical Systems America, Inc. · 2016
  8. 7 generations backK163528 HITACHI Supria Whole-body X-ray CT System Phase 3Hitachi Medical Systems America, Inc. · 2017
  9. 6 generations backK171738 Supria True64Hitachi Healthcare Americas Corporation · 2017
  10. 5 generations backK190841 SCENARIA ViewHitachi Healthcare Americas · 2019
  11. 4 generations backK200498 SCENARIA ViewHitachi Healthcare Americas · 2020
  12. 3 generations backK213829 SCENARIA ViewFujifilm Healthcare Corporation · 2022 · Recalled
  13. 2 generations backK231574 Scenaria View 4.2FUJIFILM Healthcare Americas Corporation · 2023
  14. 1 generation backK250370 SCENARIA View Phase 5.0Fujifilm Corporation · 2025
  15. This deviceK253836 FCT iStream Phase 2Fujifilm Corporation · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K031469Aquilion Super 4 Multislice CT Scanner, Model TSX-101A/7Toshiba America Medical Systems, In.C20031
−13K033418TSX-101A/a and TSX-101A/C Aquilion Multislice CT ScannersToshiba America Medical Systems, In.C20032
−12K051833TSX-101A/H Aquilion 64 SP CT Scanner; TSX-101A/I Aquilion 32 SP CT ScannerToshiba America Medical Systems, In.C2005—
−11K080211Model TSX-101A/H/I Aquilion 32/64 SP CT SystemToshiba America Medical Systems, In.C20088
−10K101888Scenaria Whole-Body X-Ray CT SystemHitachi Medical Systems America, Inc.20113
−9K123509Scenaria Phase 2 Whole-Body X-Ray CT SystemHitachi Medical Systems America, Inc.2013—
−8K161748SUPRIA w/guideShot OptionHitachi Medical Systems America, Inc.2016—
−7K163528HITACHI Supria Whole-body X-ray CT System Phase 3Hitachi Medical Systems America, Inc.2017—
−6K171738Supria True64Hitachi Healthcare Americas Corporation2017—
−5K190841SCENARIA ViewHitachi Healthcare Americas2019—
−4K200498SCENARIA ViewHitachi Healthcare Americas2020—
−3K213829SCENARIA ViewFujifilm Healthcare Corporation20221
−2K231574Scenaria View 4.2FUJIFILM Healthcare Americas Corporation2023—
−1K250370SCENARIA View Phase 5.0Fujifilm Corporation2025—
0 (this device)K253836FCT iStream Phase 2Fujifilm Corporation2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201510
FIG. 1 — Lineage of K253836, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K250370SCENARIA View Phase 5.0
Summary page 5
…892.1750 Product Code(s) JAK Legally Marketed Predicate Device and Reference Device Primary Predicate Device Predicate # K250370 Device Trade Name SCENARIA View Phase 5.0 Common Name System, x-ray, tomography, computed Class…
Fujifilm Corporation2025—
†K233583FCT iSTREAM Phase 1FUJIFILM Healthcare Americas Corporation2024—

Also cleared against K250370: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 7 companies; a new generation was cleared every 1.7 years on median.
  • 6 of the 15 ancestors have a recall of any class.
  • 1 other device also cites its predicate K250370.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The FCT iStream system is indicated to acquire axial volumes of the whole body including the head. Images can be acquired in axial, helical, or dynamic modes. The FCT iStream system can also be used for interventional needle guidance. Volume datasets acquired by an FCT iStream system can be post-processed in the FCT iStream system to provide additional information. Post-processing capabilities of the FCT iStream software include multi-planar…

Read the full statement (255 words)

The FCT iStream system is indicated to acquire axial volumes of the whole body including the head. Images can be acquired in axial, helical, or dynamic modes. The FCT iStream system can also be used for interventional needle guidance. Volume datasets acquired by an FCT iStream system can be post-processed in the FCT iStream system to provide additional information. Post-processing capabilities of the FCT iStream software include multi-planar reconstruction (MPR), and volume rendering. Volume datasets acquired by an FCT iStream system can be transferred to external devices via a DICOM standard interface.

The Low Dose CT Lung Cancer Screening Option for the FCT iStream system is indicated for using low dose CT for lung cancer screening. The screening must be conducted with the established program criteria and protocols that have been approved and published by a governmental body, a professional medical society, and/or FUJIFILM Corporation.

AI/ML algorithms are used for Intelli IPV, AutoPose and AutoPositioning.

Intelli IPV is an iterative image reconstruction function incorporating machine learning-based AI technology.

AutoPose is developed using deep learning as AI technology to detect landmarks or regions from a scanogram image. When using AutoPose, be sure to visually check the scan range and adjust it if necessary.

AutoPositioning is developed using deep learning as AI technology to detect the patient’s feature points. This function assists in patient positioning operations. Therefore, after completing the positioning operation, be sure to visually check the patient's positioning and the table position by using the light localizer.

AutoPose and AutoPositioning are for adult use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K253836: FCT iStream Phase 2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253836

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026