510(k) Report

510(k) · Cleared

Recalled · Class II · 2015

GE Precision Mpi

K033486510(k) TraditionalCleared Nov 19, 200315-day reviewClass II21 CFR 892.1650Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nrt-Nordisk Rontgen Teknik A/S · OWB Interventional Fluoroscopic X-Ray System

Cleared on Nov 19, 2003 as substantially equivalent to K961374 (Philips Medical Systems, Inc., 1996) after a 15-day review. Its family tree reaches back 1 generation to 1996. 1 later device descends from it. It has been recalled 7 times.

Decided
Nov 19, 2003
Review
15 days
Class
Class II
Product code
OWB
Recalls
7
Predicates
1

Its longest line of descent runs back 1 generation to K961374 (1996). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2018: 1 descendant clearedK961374 · Philips Multidiagnost 4 · Philips Medical Systems, Inc. · 1996 · recalled1995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K961374 · Philips Multidiagnost 4 · Philips Medical Systems, Inc. · 1996 · recalled0
  1. Root · 1 generation backK961374 Philips Multidiagnost 4Philips Medical Systems, Inc. · 1996 · Recalled
  2. This deviceK033486 GE Precision MpiNrt-Nordisk Rontgen Teknik A/S · 2003
  3. Descendant · cites it directly · 0 of its ownK173631 Intelli-CNrt X-Ray A/S · 2018 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K173631Intelli-CNrt X-Ray A/S · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K961374Philips Multidiagnost 4Philips Medical Systems, Inc.19963
0 (this device)K033486GE Precision MpiNrt-Nordisk Rontgen Teknik A/S2003—
+1K173631Intelli-CNrt X-Ray A/S20184

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
FIG. 1 — Lineage of K033486, 1996–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.2 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K961374Philips Multidiagnost 4
Summary page 1
…iology, Image-intensified fluoroscopic x-ray system Product code: JAA ) 0 Wp Legally marketed device to which we claim equivalence: Philips MultiDiagnost 4, 510(K) no. K961374. Device Description: The GE Precision MPi tilt-C consists of an X-ray Generator, Right or Left side suspended Angulations Table…
Philips Medical Systems, Inc.19963

Also cleared against K961374: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173631Intelli-CNrt X-Ray A/S20180

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 12, 2015Class IIZ-2123-2015Nonconforming Material/ComponentA reported incident of a monitor that fell from the suspension. A fall of a monitor could result in an injury to a patient or operator. Recall affects the single and dual LCD monitor suspensions used on Precision 500D Classical R & F…
Dec 12, 2013Class IIZ-0911-2014Device DesignGE Healthcare has recently become aware of a potential safety issue involving the Precision 500D, Precision MPI & Precision RXI X-ray imaging systems overhead LCD Video Monitor Suspension (Single monitor & Dual monitor). There is a…
May 1, 2009Not classifiedZ-1658-2009Radiation Control for Health and Safety ActThe GE Precision MPi is in violation with 21 CFR Part 1020.32 requiring a signal audible to the fluoroscopist to sound for each passage of 5 minutes of fluoroscopic irradiation time during an examination or procedure.
Jul 1, 2008Class IIZ-0753-2016Radiation Control for Health and Safety ActIt was discovered that the Remote Touch Panel (RTP) of the GE Precision MPi X-ray system may not always boot up as intended and needs to be updated to properly accomplish its intended purpose.
May 1, 2008Not classifiedZ-2143-2008Radiation Control for Health and Safety ActThe Precision MPi collimator did not contain a label identifying the device as being certified to comply with applicable requirements of the x-ray performance standard.
May 1, 2008Not classifiedZ-2144-2008Radiation Control for Health and Safety ActThe Precision MPi collimator did not contain a label identifying the device as being certified to comply with applicable requirements of the x-ray performance standard.
May 1, 2008Not classifiedZ-2142-2008Radiation Control for Health and Safety ActThe Precision MPi collimator did not contain a label identifying the device as being certified to comply with applicable requirements of the x-ray performance standard.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K173631 (Nrt X-Ray A/S, 2018) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K961374.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

The GE Precision MPi is a multi-purpose system that can perform general R&F, radiography, fluoroscopy, interventional and angiography procedures/applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K033486: GE Precision Mpi.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K033486

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026