510(k) Report

510(k) · Cleared

Recalled · 2009

Philips Multidiagnost 4

K961374510(k) TraditionalCleared Aug 19, 1996132-day reviewClass II21 CFR 892.1650Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems, Inc. · OWB Interventional Fluoroscopic X-Ray System

Cleared on Aug 19, 1996 after a 132-day review. The FDA summary names no predicate by number. 4 later devices descend from it. It has been recalled 3 times.

Decided
Aug 19, 1996
Review
132 days
Class
Class II
Product code
OWB
Recalls
3
Predicates
0

4 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2002: 1 descendant cleared2005: 1 descendant cleared2018: 1 descendant cleared1995200020052010201520202025
  1. This deviceK961374 Philips Multidiagnost 4Philips Medical Systems, Inc. · 1996
  2. Descendant · cites it directly · 1 of its ownK033486 GE Precision MpiNrt-Nordisk Rontgen Teknik A/S · 2003 · Recalled
  3. Descendant · cites it directly · 1 of its ownK023441 Philips Multidiagnost ElevaPhilips Medical Systems · 2002 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK173631 Intelli-CNrt X-Ray A/S · 2018 · Recalled
  5. Descendant · 2 generations on · 0 of its ownK050151 Multidiagnost ElevaPhilips Medical Systems North America, Inc. · 2005 · Recalled

Most influential descendants

Showing 4 of 4 · See all
  • K033486GE Precision MpiNrt-Nordisk Rontgen Teknik A/S · 2003 · cites it directly1descendant
  • K023441Philips Multidiagnost ElevaPhilips Medical Systems · 2002 · cites it directly1descendant
  • K173631Intelli-CNrt X-Ray A/S · 2018 · 2 generations on0descendants
  • K050151Multidiagnost ElevaPhilips Medical Systems North America, Inc. · 2005 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K961374Philips Multidiagnost 4Philips Medical Systems, Inc.1996—
+1K033486GE Precision MpiNrt-Nordisk Rontgen Teknik A/S20037
+1K023441Philips Multidiagnost ElevaPhilips Medical Systems200215
+2K173631Intelli-CNrt X-Ray A/S20184
+2K050151Multidiagnost ElevaPhilips Medical Systems North America, Inc.200521

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200510
201810
FIG. 1 — Lineage of K961374, 1996–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.2 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033486GE Precision MpiNrt-Nordisk Rontgen Teknik A/S20031
K023441Philips Multidiagnost ElevaPhilips Medical Systems20021

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 6, 2009Not classifiedZ-1664-2009Radiation Control for Health and Safety ActThe x-ray system fail to meet the requirements of 21 CFR 1020.32(d)(2)(ii) when a specific tube failure occurs involving fluoroscopy of large patients and a partial failure of the grid switch
Apr 6, 2006Not classifiedZ-0852-06OtherPotential for unexpected table movement.
Jan 10, 2003Not classifiedZ-0586-03OtherINTERNAL SHORT CIRCUIT - MAY ALLOW FOR STAND AND TABLE TO MOVE SPONTANEOUSLY IN UPWARD OR DOWNWARD MOVEMENT

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K033486 (Nrt-Nordisk Rontgen Teknik A/S, 2003) has gone furthest, with 1 descendant of its own.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

The MultiDIAGNOST 4 is indicated for use in Radiographic/Fluoroscopic, Angiographic, and Interventional diagnostic imaging examinations.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K961374: Philips Multidiagnost 4.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K961374

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026