K040444510(k) SpecialCleared Apr 14, 200485-day reviewClass II21 CFR 892.1000Recalls 10 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

General Electric Co. · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Apr 14, 2004 as substantially equivalent to K022397 (GE Medical Systems, 2002) after an 85-day review. Its family tree reaches back 2 generations to 1999. 1 of the 6 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it. It has been recalled 10 times, including a Class I recall.

Decided
Apr 14, 2004
Review
85 days
Class
Class II
Product code
LNH
Recalls
10 (1 Class I)
Predicates
1

Its longest line of descent runs back 2 generations to K990550 (1999). 3 ancestors in all. 2 later devices descend from it, 2 citing it directly. 1 of the 6 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2008: 1 descendant cleared2005: 1 descendant clearedK990550 · 3.0T Signa VH/I Magnetic Resonance System · Ge Medical Systems, Inc. · 1999K022397 · Signa 3.0T Magnetic Resonance System · GE Medical Systems · 2002 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 2 descendants K022397 · Signa 3.0T Magnetic Resonance System · GE Medical Systems · 2002 · recalledK990550 · 3.0T Signa VH/I Magnetic Resonance System · Ge Medical Systems, Inc. · 19990
  1. Root · 2 generations backK990550 3.0T Signa VH/I Magnetic Resonance SystemGe Medical Systems, Inc. · 1999
  2. 1 generation backK022397 Signa 3.0T Magnetic Resonance SystemGE Medical Systems · 2002 · Recalled
  3. This deviceK040444 GE Signa 3.0T with Excite MR SystemGeneral Electric Co. · 2004
  4. Descendant · cites it directly · 0 of its ownK080820 Tem 3002G- HN Dual Tune Head CoilMr Instruments, Inc. · 2008
  5. Descendant · cites it directly · 0 of its ownK052200 Tem 3000 Head CoilMr Instruments, Inc. · 2005

Most influential descendants

Showing 2 of 2 · See all
  • K080820Tem 3002G- HN Dual Tune Head CoilMr Instruments, Inc. · 2008 · cites it directly0descendants
  • K052200Tem 3000 Head CoilMr Instruments, Inc. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K9905503.0T Signa VH/I Magnetic Resonance SystemGe Medical Systems, Inc.1999—
−1K022397Signa 3.0T Magnetic Resonance SystemGE Medical Systems20021
0 (this device)K040444GE Signa 3.0T with Excite MR SystemGeneral Electric Co.2004—
+1K080820Tem 3002G- HN Dual Tune Head CoilMr Instruments, Inc.2008—
+1K052200Tem 3000 Head CoilMr Instruments, Inc.2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200810
FIG. 1 — Lineage of K040444, 1999–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022397Signa 3.0T Magnetic Resonance System
Summary page 1
…2.1000, 90-LNH Marketed Device: The GE Signa® 3.OT with Excite Magnetic Resonance System is substantially equivalent to the currently marketed Signa® 3.OT MR system (K022397) with the main differences being an addition of eight independent receive channels as part of a system upgrade. Device Descrip…
GE Medical Systems20021

Also cleared against K022397: 1 other device →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080820Tem 3002G- HN Dual Tune Head CoilMr Instruments, Inc.20080
K052200Tem 3000 Head CoilMr Instruments, Inc.20050

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 23, 2021Class IIZ-0614-2022Process controlThe magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
Jun 7, 2018Class IIZ-0112-2019Software change controlThe latest on-site software version may not have been reinstalled at some sites after service activities were performed resulting in images possibly flipped left/right and/or there can be patient data mismatch.
Jun 7, 2018Class IIZ-0110-2019Software change controlThe latest on-site software version may not have been reinstalled at some sites after service activities were performed resulting in images possibly flipped left/right and/or there can be patient data mismatch.
Jun 7, 2018Class IIZ-0111-2019Software change controlThe latest on-site software version may not have been reinstalled at some sites after service activities were performed resulting in images possibly flipped left/right and/or there can be patient data mismatch.
Aug 31, 2015Class IIZ-0256-2016Software designWhen performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could…
Jul 10, 2015Class IIZ-2339-2015Nonconforming Material/ComponentA gradient cable in the ACGD cabinet may be missing a spacer that prevents connecting the gradient cable terminals in the wrong polarity on X gradient amplifier. This could cause images to be flipped left-right with incorrect orientation…
Mar 9, 2015Class IIZ-1305-2015Software Manufacturing/Software DeploymentGE Healthcare has become aware of a potential safety issue involving MRI systems due to software versions not being maintained properly at some sites.
Jan 7, 2015Class IZ-1035-2015Employee errorAt certain sites, the MRU may not be connected to the magnet. In emergency situations, a disconnected MRU could delay removal of a ferrous object from the magnet, potentially resulting in life-threatening injuries. The MRU must be…
Nov 21, 2011Class IIZ-1943-2013Software designScreen save images are included in wrong exam due to duplicate UID creation. This may cause a safety issue due to a potential patient data mismatch.While the issue has only been observed at one customer site on the Signa HDxT 1.5T system…
Jun 1, 2006Not classifiedZ-0815-2007OtherTo provide the 3.0T MRI systems users with the 8-channel brain coil the proper coil weighting software. The proper coil weighting factors for the eight-channel brain coil were not included in the software.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 3.3 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K080820 (Mr Instruments, Inc., 2008) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K022397.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

The GE Signa® 3.OT with Excite is a whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio and short scan times. The Signa® 3.OT with Excite MR System is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images, spectroscopic images, and/or spectra, dynamic images of the internal structures and organs of the entire body, including, but not limited to…

Read the full statement (127 words)

The GE Signa® 3.OT with Excite is a whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio and short scan times. The Signa® 3.OT with Excite MR System is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images, spectroscopic images, and/or spectra, dynamic images of the internal structures and organs of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the Signa® 3.OT with Excite MR systems reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040444: GE Signa 3.0T with Excite MR System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040444

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.