510(k) Report

510(k) · Cleared

Recalled · 2011

Variant II Hemoglobin A1C

K040872510(k) TraditionalCleared Apr 15, 200413-day reviewClass II21 CFR 864.7470Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Rad Laboratories, Inc. · LCP Assay, Glycosylated Hemoglobin

Cleared on Apr 15, 2004 as substantially equivalent to K984268 (Bio-Rad, 1998) after a 13-day review. Its family tree reaches back 2 generations to 1993. 3 later devices descend from it. It has been recalled 4 times.

Decided
Apr 15, 2004
Review
13 days
Class
Class II
Product code
LCP
Recalls
4
Predicates
1

Its longest line of descent runs back 2 generations to K926469 (1993). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2006: 1 descendant cleared2007: 1 descendant cleared2014: 1 descendant clearedK926469 · Variant (TM) Hemoglobin a 1C Program · Bio-Rad · 1993K984268 · Variant II Hemoglobin A1C Program · Bio-Rad · 1998 · recalled1990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant K984268 · Variant II Hemoglobin A1C Program · Bio-Rad · 1998 · recalledK926469 · Variant (TM) Hemoglobin a 1C Program · Bio-Rad · 19930
  1. Root · 2 generations backK926469 Variant (TM) Hemoglobin a 1C ProgramBio-Rad · 1993
  2. 1 generation backK984268 Variant II Hemoglobin A1C ProgramBio-Rad · 1998 · Recalled
  3. This deviceK040872 Variant II Hemoglobin A1CBio-Rad Laboratories, Inc. · 2004
  4. Descendant · cites it directly · 2 of its ownK063400 Variant II Turbo Hemoglobin A1C Program, Hemoglobin Testing System…Bio-Rad Laboratories, Inc. · 2006 · Recalled
  5. Descendant · cites it directly · 1 of its ownK070819 Variant II Turbo Link Hemoglobin A1C Program, and Variant II Turbo…Bio-Rad Laboratories Inc., Clinical Systems Divisi · 2007 · Recalled
  6. Descendant · 2 generations on · 0 of its ownK140801 Variant II Turbo Link Hemoglobin A1C Program/Testing SystemBio-Rad Laboratories, Inc. · 2014

Most influential descendants

Showing 3 of 3 · See all
  • K063400Variant II Turbo Hemoglobin A1C Program, Hemoglobin Testing System with CDM 4.0Bio-Rad Laboratories, Inc. · 2006 · cites it directly2descendants
  • K070819Variant II Turbo Link Hemoglobin A1C Program, and Variant II Turbo Link Hemoglobin…Bio-Rad Laboratories Inc., Clinical Systems Divisi · 2007 · cites it directly1descendant
  • K140801Variant II Turbo Link Hemoglobin A1C Program/Testing SystemBio-Rad Laboratories, Inc. · 2014 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K926469Variant (TM) Hemoglobin a 1C ProgramBio-Rad1993—
−1K984268Variant II Hemoglobin A1C ProgramBio-Rad19982
0 (this device)K040872Variant II Hemoglobin A1CBio-Rad Laboratories, Inc.2004—
+1K063400Variant II Turbo Hemoglobin A1C Program, Hemoglobin Testing System with CDM 4.0Bio-Rad Laboratories, Inc.20064
+1K070819Variant II Turbo Link Hemoglobin A1C Program, and Variant II Turbo Link…Bio-Rad Laboratories Inc., Clinical Systems Divisi20075
+2K140801Variant II Turbo Link Hemoglobin A1C Program/Testing SystemBio-Rad Laboratories, Inc.2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200710
201410
FIG. 1 — Lineage of K040872, 1993–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LCP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LCP device

  1. #1 K221326 Nova Allegro HbA1c Assay, Nova Allegro Analyzerscore 9.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K984268Variant II Hemoglobin A1C Program
Summary page 1
…Assay, Glycosylated Hemoglobin, 81LCP Predicate Device: VARIANT TM II Hemoglobin Alc Program K984268 Bio-Rad Laboratories, Inc. Intended Use: The Bio-Rad VARIANT II T…
Bio-Rad19982

Also cleared against K984268: 5 other devices →

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K063400Variant II Turbo Hemoglobin A1C Program, Hemoglobin Testing System with CDM 4.0Bio-Rad Laboratories, Inc.20062
K070819Variant II Turbo Link Hemoglobin A1C Program, and Variant II Turbo Link Hemoglobin…Bio-Rad Laboratories Inc., Clinical Systems Divisi20071

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 12, 2011Not classifiedZ-0020-2012Process controlA previous recall related to reports of calibration failure and late retention times using Elution Buffer led to an examination of other buffers manufactured during the same time period and a decision was made to field correct these…
Sep 12, 2011Not classifiedZ-0021-2012Process controlA previous recall related to reports of calibration failure and late retention times using Elution Buffer led to an examination of other buffers manufactured during the same time period and a decision was made to field correct these…
Sep 12, 2011Not classifiedZ-0022-2012Process controlA previous recall related to reports of calibration failure and late retention times using Elution Buffer led to an examination of other buffers manufactured during the same time period and a decision was made to field correct these…
Mar 24, 2010Not classifiedZ-1342-2011OtherThe firm received customer complaints associated with the Update Kit CD-ROM not being able to generate a valid calibration after being uploaded, resulting in patient results not being generated.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 5.7 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K063400 (Bio-Rad Laboratories, Inc., 2006) has gone furthest, with 2 descendants of its own.
  • 5 other devices also cite its predicate K984268.

How does its category compare?

All LCP devices

LCP Assay, Glycosylated Hemoglobin: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LCP

1in 2024

2007: 72008: 52009: 62010: 22011: 102012: 92013: 22014: 82015: 32016: 22017: 52018: 22019: 42020: 12023: 22024: 1
2007high 10 (2011) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LCP

269in 2019

2007: 133 days median2008: 206 days median2009: 158 days median2011: 176 days median2012: 143 days median2014: 127 days median2015: 239 days median2017: 218 days median2019: 269 days median
2007high 269 (2019) · low 127 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LCP

1in 2025

2007: 12008: 32009: 62010: 52011: 512013: 42014: 22015: 22016: 62017: 12018: 12022: 12024: 12025: 1
2007high 51 (2011) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LCP

22in 2025

2007: 52008: 112009: 152010: 42011: 272012: 512013: 1932014: 1822015: 642016: 292017: 1492018: 1,9112019: 1142020: 132021: 72022: 82023: 272024: 392025: 22
2007high 1,911 (2018) · low 4 (2010)2025

MAUDE reports naming product code LCP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007713315
20085206311
20096158615
20102—54
2011101765127
20129143051
20132—4193
201481272182
20153239264
20162—629
201752181149
20182—11,911
201942690114
20201—013
20210—07
20220—18
20232—027
20241—139
20250—122
20260—0—

What is it indicated for?

The Bio-Rad VARIANT II TURBO Hemoglobin A1c Program is intended for the percent determination of hemoglobin A1c in human whole blood using ion-exchange high-performance liquid chromatography (HPLC).

The Bio-Rad VARIANT II TURBO Hemoglobin A1c Program is intended for Professional Use Only. For In Vitro Diagnostic Use.

Measurement of percent hemoglobin A1c is effective in monitoring long-term glucose control in individuals with diabetes mellitus.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040872: Variant II Hemoglobin A1C.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040872

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026