510(k) Report

510(k) · Cleared

Recalled · Class II · 2013

Siemens Enhanced Imaging System

K041166510(k) TraditionalCleared May 17, 200413-day reviewClass II21 CFR 892.1200Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · KPS System, Tomography, Computed, Emission

Cleared on May 17, 2004 as substantially equivalent to K992731 (Siemens Medical Solutions USA, Inc., 1999) and 3 other predicates after a 13-day review. Its family tree reaches back 3 generations to 1995. 7 of the 96 devices in its family, counting itself, have a Class I recall. 87 later devices descend from it. It has been recalled 12 times.

Decided
May 17, 2004
Review
13 days
Class
Class II
Product code
KPS
Recalls
12
Predicates
4

Its longest line of descent runs back 3 generations to K952674 (1995). 8 ancestors in all, the oldest K892358 (1989). 87 later devices descend from it, 3 citing it directly. 7 of the 96 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor1999: 1 other ancestor1995: 1 other ancestor1991: 1 other ancestor1989: 1 other ancestor2008: 1 descendant cleared2007: 2 descendants cleared2013: 2 descendants cleared2011: 3 descendants cleared, 2 with a Class I recall22010: 1 descendant cleared2009: 1 descendant cleared, 1 with a Class I recall12016: 2 descendants cleared, 1 with a Class I recall12025: 13 descendants cleared2018: 4 descendants cleared, 1 with a Class I recall12014: 1 descendant cleared2012: 1 descendant cleared, 1 with a Class I recall12017: 1 descendant cleared2021: 10 descendants cleared2020: 4 descendants cleared2019: 3 descendants cleared2023: 10 descendants cleared2024: 10 descendants cleared2022: 7 descendants cleared2026: 11 descendants clearedK952674 · Transact: Attenuation Correction System for the Apex Cardial Gamma Camera · Elscint, Inc. · 1995 · recalledK980959 · Vtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma Camera · Ge Medical Systems F.I. Haifa · 1998K991841 · Hawkeye Option for Dual-Head Variable Angle Gamma Camera · Ge Medical Systems F.I. Haifa · 1999 · Class I recall1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 5 descendants, 1 with a Class I recall13 generations forward: 5 descendants, 3 with a Class I recall34 generations forward: 7 descendants, 2 with a Class I recall25 generations forward: 4 descendants6 generations forward: 6 descendants7 generations forward: 9 descendants8 generations forward: 20 descendants9 generations forward: 12 descendants10 generations forward: 7 descendants11 generations forward: 3 descendants12 generations forward: 5 descendants13 generations forward: 1 descendant K991841 · Hawkeye Option for Dual-Head Variable Angle Gamma Camera · Ge Medical Systems F.I. Haifa · 1999 · Class I recallK980959 · Vtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma Camera · Ge Medical Systems F.I. Haifa · 1998K952674 · Transact: Attenuation Correction System for the Apex Cardial Gamma Camera · Elscint, Inc. · 1995 · recalled0+5+10
  1. Root · 3 generations backK952674 Transact: Attenuation Correction System for the Apex Cardial Gamma…Elscint, Inc. · 1995 · Recalled
  2. 2 generations backK980959 Vtransact: Attenuation Correction System for Dual-Head Variable…Ge Medical Systems F.I. Haifa · 1998
  3. 1 generation backK991841 Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa · 1999 · Recalled (Class I)
  4. This deviceK041166 Siemens Enhanced Imaging SystemSiemens Medical Solutions USA, Inc. · 2004
  5. Descendant · cites it directly · 86 of its ownK063826 Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc. · 2007
  6. Descendant · cites it directly · 85 of its ownK072567 Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc. · 2007 · Recalled
  7. Descendant · cites it directly · 83 of its ownK082506 Symbia, Version 4.0Siemens Medical Solutions USA, Inc. · 2008 · Recalled
  8. Descendant · 2 generations on · 66 of its ownK131634 SymbiaSiemens Medical Solutions USA, Inc. · 2013 · Recalled
  9. Descendant · 3 generations on · 65 of its ownK142006 Symbia 6.0Siemens Medical Solutions USA, Inc. · 2014 · Recalled

Showing 5 of 87 descendants. See all descendants

Descendants cleared per year

2007: 22008: 12009: 12010: 12011: 32012: 12013: 22014: 12016: 22017: 12018: 42019: 32020: 42021: 102022: 72023: 102024: 102025: 132026: 11
2007high 13 (2025) · low 0 (2015)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 87 · See all
  • K063826Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc. · 2007 · cites it directly86descendants
  • K072567Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc. · 2007 · cites it directly85descendants
  • K082506Symbia, Version 4.0Siemens Medical Solutions USA, Inc. · 2008 · cites it directly83descendants
  • K131634SymbiaSiemens Medical Solutions USA, Inc. · 2013 · 2 generations on66descendants
  • K142006Symbia 6.0Siemens Medical Solutions USA, Inc. · 2014 · 3 generations on65descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K952674Transact: Attenuation Correction System for the Apex Cardial Gamma CameraElscint, Inc.19951
−2K980959Vtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma…Ge Medical Systems F.I. Haifa1998—
−1K991841Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa1999Class I
0 (this device)K041166Siemens Enhanced Imaging SystemSiemens Medical Solutions USA, Inc.2004—
+1K063826Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc.2007—
+1K072567Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc.20072
+1K082506Symbia, Version 4.0Siemens Medical Solutions USA, Inc.20089
+2K131634SymbiaSiemens Medical Solutions USA, Inc.20137
+3K142006Symbia 6.0Siemens Medical Solutions USA, Inc.20149

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199110
199510
199910
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200720
200810
200911
201010
201132
201211
201320
201410
201621
201710
201841
201930
202040
2021100
202270
2023100
2024100
2025130
2026110
FIG. 1 — Lineage of K041166, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

7 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPS device

  1. #1 K253564 uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI…score 18.6 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992731E.Cam Computer
Summary page 1
…Modification of a legally marketed device Identification of Legally Marketed Equivalent Devices 510(k) Number Date of Clearance Device Name K992731 November 10, 1999 Siemens, e.Cam Computer K(952109 August 23, 1995 Siemens, tp 500 Nuclear Ga…
Siemens Medical Solutions USA, Inc.19991
*K952109IP500 Nuclear Gamma Camera System
Summary page 1
…ly Marketed Equivalent Devices 510(k) Number Date of Clearance Device Name K992731 November 10, 1999 Siemens, e.Cam Computer K(952109 August 23, 1995 Siemens, tp 500 Nuclear Gamma Camera System K…
Siemens Medical Solutions USA, Inc.19957
*K991841Hawkeye Option for Dual-Head Variable Angle Gamma Camera
Summary page 1
…Siemens, e.Cam Computer K(952109 August 23, 1995 Siemens, tp 500 Nuclear Gamma Camera System K991841 August 26, 1999 General Electric, Hawkeye Option for Dual-Head Vari…
Ge Medical Systems F.I. Haifa1999Class I
*K023687Somatom Emotion 6 CT Systems
Summary page 1
…ral Electric, Hawkeye Option for Dual-Head Variable Angle Gamma Camera K023687 November 22, 2002 Siemens Somatomn CT System 510(k) Summary of Safety and Effecti…
Siemens Medical Systems, Inc.20026

Also cleared against K992731: 4 other devices →

What descends from it? (87)

See all 87

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K063826Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc.200786
K072567Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc.200785
K082506Symbia, Version 4.0Siemens Medical Solutions USA, Inc.200883

Has anything in its family been recalled? (7 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 16, 2013Class IIZ-0061-2017Component design/selectionThe detectors on the Symbia S and Symbia T camera systems are supported and moved horizontally and vertically by four linear bearing cars. There is a potential for the linear bearing car to fail allowing the ball bearings to fall out.
Oct 23, 2012Class IIZ-1086-2015Component design/selectionThere is a potential for the linear bearing car to fail allowing the ball bearings to fall out.
Dec 11, 2009Not classifiedZ-0584-2010Process controlSome of the hand controllers of the Symbia S & T systems are missing a resistor switch, and the absence of the switch may lead to unintended system motion during camera set up activities.
Dec 11, 2009Not classifiedZ-0583-2010Process controlSome of the hand controllers of the Symbia S & T systems are missing a resistor switch, and the absence of the switch may lead to unintended system motion during camera set up activities.
Apr 22, 2009Not classifiedZ-1676-2009Finished device change controlThe pinion gear could crack and cause the gantry to spin freely thereby damaging the Symbia S or T System and potentially injuring a patient during a scan.
Apr 22, 2009Not classifiedZ-1677-2009Finished device change controlThe pinion gear could crack and cause the gantry to spin freely thereby damaging the Symbia S or T System and potentially injuring a patient during a scan.
Mar 11, 2009Not classifiedZ-1649-2009Software designPatient injury can occur when the patient is lying on the patient bed and the automatic collimator exchanger is undergoing a collimator change operation at the launch of an acquisition workflow. Detector motions required for this change…
Mar 11, 2009Not classifiedZ-1648-2009Software designPatient injury can occur when the patient is lying on the patient bed and the automatic collimator exchanger is undergoing a collimator change operation at the launch of an acquisition workflow. Detector motions required for this change…
Sep 29, 2008Not classifiedZ-0190-2009Nonconforming Material/ComponentThe protective plastic cap over the CT gantry power switch on the Line Connection Box may come loose, exposing the energized electrical contacts within the switch, thereby causing an electric hazard.
Sep 29, 2008Not classifiedZ-0189-2009Nonconforming Material/ComponentThe protective plastic cap over the CT gantry power switch on the Line Connection Box may come loose, exposing the energized electrical contacts within the switch, thereby causing an electric hazard.
Jan 30, 2007Not classifiedZ-0549-2007OtherSymbia systems, running on e.soft version 5.5 or earlier, could allow a fully-extended patient pallet to come into contact with the pinhole collimator, resulting in system damage.
Jan 30, 2007Not classifiedZ-0548-2007OtherSymbia systems, running on e.soft version 5.5 or earlier, could allow a fully-extended patient pallet to come into contact with the pinhole collimator, resulting in system damage.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K991841Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa · 1999 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
  • K093514Discovery Model NM/CT 670Ge Medical Systems F.I. Haifa · 2009 · 2 generations on · ◆ in the 2009 descendants bar of FIG. 12 Class I recalls
  • K153402Discovery NM/CT 670 CZTGE Healthcare · 2016 · 3 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K173816NM/CT 850, NM/CT 860GE Healthcare · 2018 · 3 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall
  • K111445Discovery NM 630GE Healthcare · 2011 · 3 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K113350Brivo NM 615GE Healthcare · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K121019Optima NM/CT 640GE Healthcare · 2012 · 4 generations on · ◆ in the 2012 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 2.7 years on median.
  • 6 of the 8 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K063826 (Siemens Medical Solutions USA, Inc., 2007) has gone furthest, with 86 descendants of its own.
  • 4 other devices also cite its predicate K992731.

How does its category compare?

All KPS devices

KPS System, Tomography, Computed, Emission: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KPS

12in 2025

2007: 82008: 172009: 92010: 32011: 72012: 62013: 112014: 112015: 32016: 112017: 112018: 132019: 32020: 122021: 152022: 52023: 122024: 112025: 122026 (partial year): 6
2007high 17 (2008) · low 3 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPS

65in 2025

2007: 38 days median2008: 25 days median2009: 42 days median2010: 91 days median2011: 28 days median2012: 94 days median2013: 84 days median2014: 92 days median2015: 112 days median2016: 65 days median2017: 104 days median2018: 59 days median2019: 60 days median2020: 72 days median2021: 66 days median2022: 60 days median2023: 63 days median2024: 59 days median2025: 65 days median2026 (partial year): 67 days median
2007high 112 (2015) · low 25 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPS

16in 2025

2007: 222008: 162009: 142010: 42011: 342012: 132013: 132014: 182015: 52016: 162017: 112018: 12, 3 Class I2019: 5, 5 Class I2020: 82021: 42022: 8, 6 Class I2023: 6, 3 Class I2024: 152025: 162026 (partial year): 6
2007high 34 (2011) · low 4 (2010)2026

Class I (17 since 2007) Class II/III not classified

Adverse event reports per year · KPS

36in 2025

2007: 382008: 112009: 152010: 442011: 562012: 342013: 2402014: 332015: 242016: 102017: 312018: 262019: 1052020: 222021: 102022: 152023: 222024: 232025: 36
2007high 240 (2013) · low 10 (2016)2025

MAUDE reports naming product code KPS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20078382238
200817251611
20099421415
2010391444
20117283456
20126941334
2013118413240
201411921833
20153112524
201611651610
2017111041131
2018135912 (3)26
20193605 (5)105
20201272822
20211566410
20225608 (6)15
202312636 (3)22
202411591523
202512651636
20266676—

What is it indicated for?

SPECT: To detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588keV.

CT: The CT component is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial place taken at different angles or spiral planes taken at different angles.

SPECT+CT: Perform CT scans and nuclear imaging studies within the same instrument. To obtain attenuation corrected images and to provide registration of anatomical and physiological images within the patient's anatomy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K041166: Siemens Enhanced Imaging System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K041166

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026