510(k) · Cleared
ClearedVtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma Camera
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ge Medical Systems F.I. Haifa · KPS System, Tomography, Computed, Emission
Cleared on Jun 4, 1998 as substantially equivalent to K952674 (Elscint, Inc., 1995) after an 82-day review. Its family tree reaches back 1 generation to 1995. 10 of the 125 devices in its family, counting itself, have a Class I recall. 123 later devices descend from it.
- Decided
- Jun 4, 1998
- Review
- 82 days
- Class
- Class II
- Product code
- KPS
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K952674 (1995). 123 later devices descend from it, 3 citing it directly. 10 of the 125 devices in this family, counting this one, have a Class I recall.
- Root · 1 generation backK952674 Transact: Attenuation Correction System for the Apex Cardial Gamma…Elscint, Inc. · 1995 · Recalled
- This deviceK980959 Vtransact: Attenuation Correction System for Dual-Head Variable…Ge Medical Systems F.I. Haifa · 1998
- Descendant · cites it directly · 120 of its ownK991841 Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa · 1999 · Recalled (Class I)
- Descendant · 2 generations on · 104 of its ownK023190 E.Cam Computer / E.Soft WorkstationSiemens Medical Solutions USA, Inc. · 2002
- Descendant · 2 generations on · 87 of its ownK041166 Siemens Enhanced Imaging SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
- Descendant · 3 generations on · 86 of its ownK063826 Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc. · 2007
- Descendant · 3 generations on · 85 of its ownK072567 Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc. · 2007 · Recalled
Showing 5 of 123 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 123 · See all- K991841Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa · 1999 · cites it directly120descendants
- K023190E.Cam Computer / E.Soft WorkstationSiemens Medical Solutions USA, Inc. · 2002 · 2 generations on104descendants
- K041166Siemens Enhanced Imaging SystemSiemens Medical Solutions USA, Inc. · 2004 · 2 generations on87descendants
- K063826Syngo MI Applications 2007ASiemens Medical Solutions USA, Inc. · 2007 · 3 generations on86descendants
- K072567Symbia-E, Model 10275879Siemens Medical Solutions USA, Inc. · 2007 · 3 generations on85descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K952674 | Transact: Attenuation Correction System for the Apex Cardial Gamma Camera | Elscint, Inc. | 1995 | 1 |
| 0 (this device) | K980959 | Vtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma… | Ge Medical Systems F.I. Haifa | 1998 | — |
| +1 | K991841 | Hawkeye Option for Dual-Head Variable Angle Gamma Camera | Ge Medical Systems F.I. Haifa | 1999 | Class I |
| +2 | K023190 | E.Cam Computer / E.Soft Workstation | Siemens Medical Solutions USA, Inc. | 2002 | — |
| +2 | K041166 | Siemens Enhanced Imaging System | Siemens Medical Solutions USA, Inc. | 2004 | 12 |
| +3 | K063826 | Syngo MI Applications 2007A | Siemens Medical Solutions USA, Inc. | 2007 | — |
| +3 | K072567 | Symbia-E, Model 10275879 | Siemens Medical Solutions USA, Inc. | 2007 | 2 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 2 | 1 |
| 2000 | 1 | 0 |
| 2002 | 2 | 1 |
| 2004 | 2 | 0 |
| 2005 | 2 | 1 |
| 2007 | 3 | 0 |
| 2008 | 4 | 1 |
| 2009 | 2 | 1 |
| 2010 | 5 | 0 |
| 2011 | 4 | 2 |
| 2012 | 2 | 1 |
| 2013 | 4 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 4 | 1 |
| 2017 | 2 | 0 |
| 2018 | 6 | 1 |
| 2019 | 3 | 0 |
| 2020 | 6 | 0 |
| 2021 | 12 | 0 |
| 2022 | 7 | 0 |
| 2023 | 12 | 0 |
| 2024 | 10 | 0 |
| 2025 | 14 | 0 |
| 2026 | 12 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
10 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KPS device
- #1 K253564 uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI…score 18.7 · 17 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K952674 | Transact: Attenuation Correction System for the Apex Cardial Gamma CameraSummary page 1…510(k) Submission Modification of legally marketed device. Identification of Legally Marketed Equivalent Devices TransACT option for the Apex Cardial. Gamma Camera - K952674 Device Description The VTransACT attenuation correction system is an addition to the Apex VariCam and Millennium VG gamma camer… | 1995 |
What descends from it? (123)
See all 1233 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (10 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K991841Hawkeye Option for Dual-Head Variable Angle Gamma CameraGe Medical Systems F.I. Haifa · 1999 · Cites it directly · ◆ in the 1999 descendants bar of FIG. 11 Class I recall
- K022960GE Quasar Nuclear Medicine SystemGe Medical Systems F.I. Haifa · 2002 · 2 generations on · ◆ in the 2002 descendants bar of FIG. 11 Class I recall
- K052434Hawkeye 4 Option for Dual-Head Variable Angle Gamma CameraGE Medical Systems · 2005 · 2 generations on · ◆ in the 2005 descendants bar of FIG. 11 Class I recall
- K093514Discovery Model NM/CT 670Ge Medical Systems F.I. Haifa · 2009 · 3 generations on · ◆ in the 2009 descendants bar of FIG. 12 Class I recalls
- K080927Brightview VCT Imaging SystemPhilips Medical Systems (Cleveland), Inc. · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 12 Class I recalls
- K121019Optima NM/CT 640GE Healthcare · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 12 Class I recalls
- K153402Discovery NM/CT 670 CZTGE Healthcare · 2016 · 4 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
- K173816NM/CT 850, NM/CT 860GE Healthcare · 2018 · 4 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall
- K111445Discovery NM 630GE Healthcare · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
- K113350Brivo NM 615GE Healthcare · 2011 · 5 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
Nearest 5 of 10; all are on the web page.
What does this lineage say?
How does its category compare?
All KPS devicesKPS System, Tomography, Computed, Emission: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KPS
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KPS
65in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KPS
16in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · KPS
36in 2025
MAUDE reports naming product code KPS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 8 | 38 | 22 | 38 |
| 2008 | 17 | 25 | 16 | 11 |
| 2009 | 9 | 42 | 14 | 15 |
| 2010 | 3 | 91 | 4 | 44 |
| 2011 | 7 | 28 | 34 | 56 |
| 2012 | 6 | 94 | 13 | 34 |
| 2013 | 11 | 84 | 13 | 240 |
| 2014 | 11 | 92 | 18 | 33 |
| 2015 | 3 | 112 | 5 | 24 |
| 2016 | 11 | 65 | 16 | 10 |
| 2017 | 11 | 104 | 11 | 31 |
| 2018 | 13 | 59 | 12 (3) | 26 |
| 2019 | 3 | 60 | 5 (5) | 105 |
| 2020 | 12 | 72 | 8 | 22 |
| 2021 | 15 | 66 | 4 | 10 |
| 2022 | 5 | 60 | 8 (6) | 15 |
| 2023 | 12 | 63 | 6 (3) | 22 |
| 2024 | 11 | 59 | 15 | 23 |
| 2025 | 12 | 65 | 16 | 36 |
| 2026 | 6 | 67 | 6 | — |
What is it indicated for?
To obtain attenuation corrected Nuclear Medicine images.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K980959 · printed Nov 4, 2026
Cite this page
510(k) Report. “K980959: Vtransact: Attenuation Correction System for Dual-Head Variable Angle Gamma Camera.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K980959
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026