510(k) · Cleared
ClearedNew Brid
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Imaging Solutions, Inc. · OWB Interventional Fluoroscopic X-Ray System
Cleared on Aug 11, 2004 as substantially equivalent to K984545 (Philips Medical Systems North America, Inc., 1999) and 2 other predicates after a 41-day review. Its family tree reaches back 3 generations to 1989.
- Decided
- Aug 11, 2004
- Review
- 41 days
- Class
- Class II
- Product code
- OWB
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 3 generations to K890348 (1989). 7 ancestors in all. No later device cites it as a predicate yet.
- Root · 3 generations backK890348 LC, Cardiac Positioner #B5078AGeneral Electric Co. · 1989 · Recalled
- 2 generations backK993037 LCV+ Version 2Ge Medical Systems, Inc. · 2000 · Recalled
- 1 generation backK023178 Innova 4100Ge Medical Systems, Inc. · 2002 · Recalled
- This deviceK041780 New BridMedical Imaging Solutions, Inc. · 2004
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K890348 | LC, Cardiac Positioner #B5078A | General Electric Co. | 1989 | 5 |
| −2 | K993037 | LCV+ Version 2 | Ge Medical Systems, Inc. | 2000 | 6 |
| −1 | K023178 | Innova 4100 | Ge Medical Systems, Inc. | 2002 | 25 |
| 0 (this device) | K041780 | New Brid | Medical Imaging Solutions, Inc. | 2004 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 1 | 0 |
| 1999 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OWB device
- #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.3 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K984545 | Release 2 of Philips Integris Series (V5000, BV5000, H5000, BH5000, HM2000) SystemsSummary page 2…cian’s discretion. 7. PREDICATE DEVICE(s): The MIS Newbrid System is substantially equivalent, in terms of its intended use in; Philips Integris Series [K984545) GE Medical System Advantx LCV+ [K960575] GE Medical System Innova [K023178] 8. SAFETY INFORMATION: The finished device and i… | 1999 |
| * | K960575 | Advantx LCV+Summary page 2…ICATE DEVICE(s): The MIS Newbrid System is substantially equivalent, in terms of its intended use in; Philips Integris Series [K984545) GE Medical System Advantx LCV+ [K960575] GE Medical System Innova [K023178] 8. SAFETY INFORMATION: The finished device and its peripherals will comply with applicable… | 1996 |
| * | K023178 | Innova 4100Summary page 2…stem is substantially equivalent, in terms of its intended use in; Philips Integris Series [K984545) GE Medical System Advantx LCV+ [K960575] GE Medical System Innova [K023178] 8. SAFETY INFORMATION: The finished device and its peripherals will comply with applicable requirements of the Underwriter Lab… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 2.8 years on median.
- 5 of the 7 ancestors have a recall of any class.
- 7 other devices also cite its predicate K984545.
How does its category compare?
All OWB devicesOWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · OWB
22in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OWB
148in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OWB
42so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OWB
14,008in 2025
MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 52 | 0 | 1 |
| 2008 | 4 | 135 | 1 | 0 |
| 2009 | 9 | 99 | 0 | 0 |
| 2010 | 7 | 66 | 0 | 0 |
| 2011 | 6 | 79 | 0 | 1 |
| 2012 | 6 | 37 | 0 | 1 |
| 2013 | 11 | 119 | 10 | 27 |
| 2014 | 15 | 158 | 9 | 103 |
| 2015 | 11 | 66 | 35 | 2,134 |
| 2016 | 16 | 103 | 13 | 4,074 |
| 2017 | 20 | 76 | 13 | 1,604 |
| 2018 | 23 | 54 | 6 | 1,449 |
| 2019 | 9 | 174 | 7 | 1,558 |
| 2020 | 16 | 53 | 8 | 1,581 |
| 2021 | 24 | 60 | 31 | 1,981 |
| 2022 | 21 | 90 | 24 | 2,932 |
| 2023 | 12 | 152 | 22 | 7,604 |
| 2024 | 13 | 126 | 11 | 7,942 |
| 2025 | 22 | 148 | 30 | 14,008 |
| 2026 | 15 | 221 | 42 | — |
What is it indicated for?
The system is intended for use in cardiovascular x-ray imaging applications, including diagnostic and interventional procedures (such as PTCA, stent placement, atherectomies), pacemaker implantations, and electrophysiology. It may also be used for other imaging applications at the physician’s discretion.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K041780 · printed Nov 4, 2026
Cite this page
510(k) Report. “K041780: New Brid.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K041780
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026