510(k) Report

510(k) · Cleared

Cleared

Balanceback VNG System

K042529510(k) TraditionalCleared Oct 6, 200419-day reviewClass II21 CFR 882.1460

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fall Prevention Technologies, LLC · GWN Nystagmograph

Cleared on Oct 6, 2004 as substantially equivalent to K925111 (Eye Dynamics, Inc., 1994) and 1 other predicate after a 19-day review. Its family tree reaches back 1 generation to 1994. 5 later devices descend from it.

Decided
Oct 6, 2004
Review
19 days
Class
Class II
Product code
GWN
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K925111 (1994). 2 ancestors in all. 5 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor2007: 1 descendant cleared2006: 1 descendant cleared2013: 1 descendant cleared2016: 1 descendant cleared2018: 1 descendant clearedK925111 · House Infrared/Video Electronystagmograph System · Eye Dynamics, Inc. · 19941990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant K925111 · House Infrared/Video Electronystagmograph System · Eye Dynamics, Inc. · 19940
  1. Root · 1 generation backK925111 House Infrared/Video Electronystagmograph SystemEye Dynamics, Inc. · 1994
  2. This deviceK042529 Balanceback VNG SystemFall Prevention Technologies, LLC · 2004
  3. Descendant · cites it directly · 2 of its ownK070729 Balanceback Mobile Intuitive VNG SystemFall Prevention Technologies, LLC · 2007
  4. Descendant · 2 generations on · 1 of its ownK152915 Eye-SyncSyncthink, Inc. · 2016
  5. Descendant · 3 generations on · 0 of its ownK181771 RightEye Vision SystemRighteye, LLC · 2018
  6. Descendant · cites it directly · 0 of its ownK130201 Nystagram Video Nystagmography SystemOtotronix, LLC · 2013
  7. Descendant · cites it directly · 0 of its ownK062015 Chronos Vision Eye Tracking Device (C-Etd)Chronos Vision · 2006

Most influential descendants

Showing 5 of 5 · See all
  • K070729Balanceback Mobile Intuitive VNG SystemFall Prevention Technologies, LLC · 2007 · cites it directly2descendants
  • K152915Eye-SyncSyncthink, Inc. · 2016 · 2 generations on1descendant
  • K181771RightEye Vision SystemRighteye, LLC · 2018 · 3 generations on0descendants
  • K130201Nystagram Video Nystagmography SystemOtotronix, LLC · 2013 · cites it directly0descendants
  • K062015Chronos Vision Eye Tracking Device (C-Etd)Chronos Vision · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K925111House Infrared/Video Electronystagmograph SystemEye Dynamics, Inc.1994—
0 (this device)K042529Balanceback VNG SystemFall Prevention Technologies, LLC2004—
+1K070729Balanceback Mobile Intuitive VNG SystemFall Prevention Technologies, LLC2007—
+2K152915Eye-SyncSyncthink, Inc.2016—
+3K181771RightEye Vision SystemRighteye, LLC2018—
+1K130201Nystagram Video Nystagmography SystemOtotronix, LLC2013—
+1K062015Chronos Vision Eye Tracking Device (C-Etd)Chronos Vision2006—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200710
201310
201610
201810
FIG. 1 — Lineage of K042529, 1994–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWN device

  1. #1 K260566 SMARTVERTIGO™ Vestibular Assessment Systemscore 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K925111House Infrared/Video Electronystagmograph System
Summary page 1
…edicate Devices: Device Name 510(k) Number Eye Dynamics, Inc. House K9251 11 Infrared/Video Electronystagmographic (ENG) System…
Eye Dynamics, Inc.1994—
*K9722432D Vog - Video-Oculography
Summary page 1
…(ENG) System _ _ _ _ _ _ _ _ _ _ Sensomotoric Instruments, Inc. 2d Vog K972243 - Video-Ocutography System __________ Indications for Use: The Balan…
Sensomotoric Instruments, GmbH1997—

Also cleared against K925111: 1 other device →

What descends from it? (5)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070729Balanceback Mobile Intuitive VNG SystemFall Prevention Technologies, LLC20072
K130201Nystagram Video Nystagmography SystemOtotronix, LLC20130
K062015Chronos Vision Eye Tracking Device (C-Etd)Chronos Vision20060

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K070729 (Fall Prevention Technologies, LLC, 2007) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K925111.

How does its category compare?

All GWN devices

GWN Nystagmograph: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GWN

3in 2025

2007: 22008: 12009: 12013: 32015: 32016: 22017: 42018: 32019: 12020: 22023: 12025: 32026 (partial year): 1
2007high 4 (2017) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWN

203in 2025

2013: 88 days median2015: 165 days median2017: 160 days median2018: 87 days median2025: 203 days median
2007high 203 (2025) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWN

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWN

1in 2025

2012: 22018: 12019: 52021: 12022: 12023: 32024: 42025: 1
2007high 5 (2019) · low 0 (2007)2025

MAUDE reports naming product code GWN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20091—00
20100—00
20110—00
20120—02
201338810
20140—00
2015316500
20162—00
2017416000
201838701
20191—05
20202—00
20210—01
20220—01
20231—03
20240—04
2025320301
20261—0—

What is it indicated for?

The BalanceBack VNG device is intended for recording, viewing, and analyzing eye movements in support of identifying balance disorders in human subjects. The VNG is intended for use only by trained physicians or clinicians in an appropriate doctor's office or health care facility. This device provides no diagnoses nor does it provide diagnostic recommendations.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042529: Balanceback VNG System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042529

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026