ClearedInfinity Gamma/Gammaxl and Vista with VF5
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Draeger Medical Systems, Inc. · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)
Cleared on Oct 6, 2004 as substantially equivalent to K033600 (Draeger Medical Systems, Inc., 2003) and 2 other predicates after an 8-day review. Its family tree reaches back 6 generations to 1995. 35 later devices descend from it.
- Decided
- Oct 6, 2004
- Review
- 8 days
- Class
- Class II
- Product code
- MHX
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 6 generations to K946306 (1995). 31 ancestors in all, the oldest K844187 (1985). 35 later devices descend from it, 1 citing it directly.
- Root · 6 generations backK946306 Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring SystemSiemens Medical Solutions USA, Inc. · 1995
- 5 generations backK982730 SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
- 4 generations backK983632 Siemens SC 8000 Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
- 3 generations backK022889 Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC…Siemens Medical Solutions USA, Inc. · 2002
- 2 generations backK031340 Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC…Siemens Medical Solutions USA, Inc. · 2003
- 1 generation backK040188 Infinity Gammaxl and SC 6802XL with the Scio Gas ModuleDraeger Medical Systems, Inc. · 2004
- This deviceK042656 Infinity Gamma/Gammaxl and Vista with VF5Draeger Medical Systems, Inc. · 2004
- Descendant · cites it directly · 34 of its ownK053484 Infinity Gamma / Gammaxl, Infinity VistaDraeger Medical Systems, Inc. · 2006 · Recalled
- Descendant · 2 generations on · 27 of its ownK060039 Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc. · 2006 · Recalled
- Descendant · 3 generations on · 26 of its ownK070566 Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/…Draeger Medical Systems, Inc. · 2007 · Recalled
- Descendant · 4 generations on · 24 of its ownK093788 Infinity Acute Care System (Iacs) Monitoring SolutionDraeger Medical Systems, Inc. · 2010 · Recalled
- Descendant · 5 generations on · 23 of its ownK113798 Infinity Acute Care System, Infinity Mcable- Masimo Rainbow SetDraeger Medical Systems, Inc. · 2012 · Recalled
Showing 5 of 35 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 35 · See all- K053484Infinity Gamma / Gammaxl, Infinity VistaDraeger Medical Systems, Inc. · 2006 · cites it directly34descendants
- K060039Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc. · 2006 · 2 generations on27descendants
- K070566Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/ SC9000XLDraeger Medical Systems, Inc. · 2007 · 3 generations on26descendants
- K093788Infinity Acute Care System (Iacs) Monitoring SolutionDraeger Medical Systems, Inc. · 2010 · 4 generations on24descendants
- K113798Infinity Acute Care System, Infinity Mcable- Masimo Rainbow SetDraeger Medical Systems, Inc. · 2012 · 5 generations on23descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K946306 | Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring System | Siemens Medical Solutions USA, Inc. | 1995 | — |
| −5 | K982730 | SC 7000 & SC 9000 XL Infinity Modular Bedside Monitor | Siemens Medical Solutions USA, Inc. | 1998 | — |
| −4 | K983632 | Siemens SC 8000 Bedside Monitor | Siemens Medical Solutions USA, Inc. | 1998 | — |
| −3 | K022889 | Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL &… | Siemens Medical Solutions USA, Inc. | 2002 | — |
| −2 | K031340 | Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC 9000XL, with… | Siemens Medical Solutions USA, Inc. | 2003 | — |
| −1 | K040188 | Infinity Gammaxl and SC 6802XL with the Scio Gas Module | Draeger Medical Systems, Inc. | 2004 | — |
| 0 (this device) | K042656 | Infinity Gamma/Gammaxl and Vista with VF5 | Draeger Medical Systems, Inc. | 2004 | — |
| +1 | K053484 | Infinity Gamma / Gammaxl, Infinity Vista | Draeger Medical Systems, Inc. | 2006 | 1 |
| +2 | K060039 | Infinity Delta and Kappa Series Monitors with VF6 Modifications | Draeger Medical Systems, Inc. | 2006 | 1 |
| +3 | K070566 | Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/ SC9000XL | Draeger Medical Systems, Inc. | 2007 | 6 |
| +4 | K093788 | Infinity Acute Care System (Iacs) Monitoring Solution | Draeger Medical Systems, Inc. | 2010 | 4 |
| +5 | K113798 | Infinity Acute Care System, Infinity Mcable- Masimo Rainbow Set | Draeger Medical Systems, Inc. | 2012 | 8 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 1990 | 3 | 0 |
| 1991 | 2 | 0 |
| 1992 | 1 | 0 |
| 1993 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 4 | 0 |
| 1997 | 2 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 2 | 0 |
| 2002 | 3 | 0 |
| 2003 | 2 | 0 |
| 2004 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
| 2007 | 2 | 0 |
| 2010 | 1 | 0 |
| 2012 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 3 | 0 |
| 2020 | 1 | 0 |
| 2021 | 2 | 0 |
| 2022 | 3 | 0 |
| 2023 | 3 | 0 |
| 2024 | 5 | 0 |
| 2025 | 3 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MHX device
- #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K033600 | Infinity GammaxlSummary page 1…tion, MSX II 870.2300 Physiological Monitors Legally Marketed Device: INFINITY GammaXL & SC 6802XL with Scio K033600, K040188 Infinity Gamma K041087 Description of Device Modifications: Software vers… | 2003 |
| * | K040188 | Infinity Gammaxl and SC 6802XL with the Scio Gas ModuleSummary page 1…MSX II 870.2300 Physiological Monitors Legally Marketed Device: INFINITY GammaXL & SC 6802XL with Scio K033600, K040188 Infinity Gamma K041087 Description of Device Modifications: Software version VF5 i… | 2004 |
| * | K041087 | Infinity GammaSummary page 1…al Monitors Legally Marketed Device: INFINITY GammaXL & SC 6802XL with Scio K033600, K040188 Infinity Gamma K041087 Description of Device Modifications: Software version VF5 is the latest release of the INFINITY Gamma/GammaXL and the Infinit… | 2004 |
What descends from it? (35)
See all 351 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K053484 | Infinity Gamma / Gammaxl, Infinity Vista | 2006 | 34 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 1.2 years on median.
- None of the 31 ancestors has a recall.
- Of its descendants, K053484 (Draeger Medical Systems, Inc., 2006) has gone furthest, with 34 descendants of its own.
- 4 other devices also cite its predicate K033600.
How does its category compare?
All MHX devicesMHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MHX
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MHX
192in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MHX
21so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MHX
3,761in 2025
MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 96 | 3 | 131 |
| 2008 | 16 | 58 | 2 | 232 |
| 2009 | 13 | 57 | 7 | 382 |
| 2010 | 20 | 90 | 13 | 955 |
| 2011 | 12 | 81 | 16 | 949 |
| 2012 | 16 | 88 | 11 | 676 |
| 2013 | 21 | 120 | 14 | 1,997 |
| 2014 | 13 | 248 | 6 | 1,609 |
| 2015 | 14 | 203 | 5 | 1,284 |
| 2016 | 13 | 149 | 7 | 1,105 |
| 2017 | 14 | 134 | 6 | 1,115 |
| 2018 | 11 | 203 | 12 | 2,157 |
| 2019 | 7 | 243 | 6 | 1,462 |
| 2020 | 11 | 196 | 0 | 1,714 |
| 2021 | 5 | 195 | 0 | 2,423 |
| 2022 | 15 | 189 | 6 | 1,470 |
| 2023 | 8 | 229 | 3 | 2,254 |
| 2024 | 5 | 181 | 3 | 2,814 |
| 2025 | 8 | 192 | 15 | 3,761 |
| 2026 | 14 | 205 | 21 | — |
What is it indicated for?
This devices are capable of monitoring: * Heart Rate * Respiration Rate * Invasive Pressure * Non-Invasive Pressure * Arrhythmia * Temperature * Arterial oxygen saturation * Pulse rate * central apnea * end-tidal C02* * ST Segment Analysis This device will produce visual and audible alarms if any of these parameters vary beyond preset limits and produce timed or alarm recordings. This device will connect to R50 recorders, either directly or via the…
Read the full statement (217 words)
This devices are capable of monitoring:
* Heart Rate
* Respiration Rate
* Invasive Pressure
* Non-Invasive Pressure
* Arrhythmia
* Temperature
* Arterial oxygen saturation
* Pulse rate
* central apnea
* end-tidal C02*
* ST Segment Analysis
This device will produce visual and audible alarms if any of these parameters vary beyond preset limits and produce timed or alarm recordings. This device will connect to R50 recorders, either directly or via the INFINITY network.
When a GammaXL is connected to a SCIO module sampled breathing gases from adults and pediatrics can be displayed. The gas module continuously measures the content of C02, N20, 02 and one of the anesthetic agents, Halothane, Isoflurane, Enflurane, Sevoflurane and Desflurane in any mixture and communicates real time and derived gas information to the GammaXL.
The device is intended to be used in an environment where patient care is provided by Healthcare Professionals, i.e. physicians, nurses, and technicians, trained on the use of the device, who will determine when use of the device is indicated, based upon their professional assessment of the patient's medical condition.
The devices are intended for use in the Adult, Pediatric and Neonatal populations, with the exception of Arrhythmia and ST Segment Analysis which are not intendedfor the neonatal population.
* not available with Infinity Vista
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K042656 · printed Nov 6, 2026
Cite this page
510(k) Report. “K042656: Infinity Gamma/Gammaxl and Vista with VF5.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042656
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026