Infinity Kappa XLT

K042904510(k) TraditionalCleared Feb 18, 2005120-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Draeger Medical Systems, Inc. · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Feb 18, 2005 as substantially equivalent to K040945 (Draeger Medical Systems, Inc., 2004) and 2 other predicates after a 120-day review. Its family tree reaches back 6 generations to 1995. 28 later devices descend from it.

Decided
Feb 18, 2005
Review
120 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to K946306 (1995). 26 ancestors in all, the oldest K900598 (1990). 28 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2001: 2 other ancestors2003: 1 other ancestor2002: 3 other ancestors2000: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestor1997: 1 other ancestor1996: 2 other ancestors1993: 1 other ancestor1992: 1 other ancestor1991: 2 other ancestors1990: 3 other ancestors2006: 1 descendant cleared2007: 1 descendant cleared2010: 1 descendant cleared2015: 1 descendant cleared2012: 1 descendant cleared2018: 1 descendant cleared2021: 2 descendants cleared2019: 2 descendants cleared2022: 3 descendants cleared2020: 1 descendant cleared2026: 3 descendants cleared2024: 5 descendants cleared2023: 3 descendants cleared2025: 3 descendants clearedK946306 · Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring System · Siemens Medical Solutions USA, Inc. · 1995×2: 2 generations cleared close together, K982730 (1998), K983632 (1998) K022889 · Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL & Siemens Infinity Explorer · Siemens Medical Solutions USA, Inc. · 2002K031340 · Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC 9000XL, with Scio · Siemens Medical Solutions USA, Inc. · 2003K033957 · Infinity Modular Monitors VF4 Modifications with Scio, Models Delta, Delta XL, Kappa, SC 8000, SC 7000, SC 9000XL · Draeger Medical Systems, Inc. · 20041990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 6 other ancestors3 generations back: 3 other ancestors4 generations back: 8 other ancestors5 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 2 descendants4 generations forward: 1 descendant5 generations forward: 4 descendants6 generations forward: 3 descendants7 generations forward: 5 descendants8 generations forward: 5 descendants9 generations forward: 6 descendants K033957 · Infinity Modular Monitors VF4 Modifications with Scio, Models Delta, Delta XL, Kappa, SC 8000, SC 7000, SC 9000XL · Draeger Medical Systems, Inc. · 2004K031340 · Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC 9000XL, with Scio · Siemens Medical Solutions USA, Inc. · 2003K022889 · Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL & Siemens Infinity Explorer · Siemens Medical Solutions USA, Inc. · 2002K983632 · Siemens SC 8000 Bedside Monitor · Siemens Medical Solutions USA, Inc. · 1998K982730 · SC 7000 & SC 9000 XL Infinity Modular Bedside Monitor · Siemens Medical Solutions USA, Inc. · 1998K946306 · Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring System · Siemens Medical Solutions USA, Inc. · 1995−50+5
  1. Root · 6 generations backK946306 Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring SystemSiemens Medical Solutions USA, Inc. · 1995
  2. 5 generations backK982730 SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
  3. 4 generations backK983632 Siemens SC 8000 Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
  4. 3 generations backK022889 Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC…Siemens Medical Solutions USA, Inc. · 2002
  5. 2 generations backK031340 Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC…Siemens Medical Solutions USA, Inc. · 2003
  6. 1 generation backK033957 Infinity Modular Monitors VF4 Modifications with Scio, Models Delta…Draeger Medical Systems, Inc. · 2004
  7. This deviceK042904 Infinity Kappa XLTDraeger Medical Systems, Inc. · 2005
  8. Descendant · cites it directly · 27 of its ownK060039 Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc. · 2006 · Recalled
  9. Descendant · 2 generations on · 26 of its ownK070566 Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/…Draeger Medical Systems, Inc. · 2007 · Recalled
  10. Descendant · 3 generations on · 24 of its ownK093788 Infinity Acute Care System (Iacs) Monitoring SolutionDraeger Medical Systems, Inc. · 2010 · Recalled
  11. Descendant · 4 generations on · 23 of its ownK113798 Infinity Acute Care System, Infinity Mcable- Masimo Rainbow SetDraeger Medical Systems, Inc. · 2012 · Recalled
  12. Descendant · 5 generations on · 19 of its ownK182543 Wearable Device ; Cradle ; Small Strap, Medium Strap, Large Strap…Snap40, Ltd. · 2018

Showing 5 of 28 descendants. See all descendants

Descendants cleared per year

2006: 12007: 12010: 12012: 12015: 12018: 12019: 22020: 12021: 22022: 32023: 32024: 52025: 32026: 3
2006high 5 (2024) · low 0 (2008)2026

Most influential descendants

Showing 5 of 28 · See all
  • K060039Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc. · 2006 · cites it directly27descendants
  • K070566Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/ SC9000XLDraeger Medical Systems, Inc. · 2007 · 2 generations on26descendants
  • K093788Infinity Acute Care System (Iacs) Monitoring SolutionDraeger Medical Systems, Inc. · 2010 · 3 generations on24descendants
  • K113798Infinity Acute Care System, Infinity Mcable- Masimo Rainbow SetDraeger Medical Systems, Inc. · 2012 · 4 generations on23descendants
  • K182543Wearable Device ; Cradle ; Small Strap, Medium Strap, Large Strap ; Multiple Device…Snap40, Ltd. · 2018 · 5 generations on19descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K946306Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring SystemSiemens Medical Solutions USA, Inc.1995—
−5K982730SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorSiemens Medical Solutions USA, Inc.1998—
−4K983632Siemens SC 8000 Bedside MonitorSiemens Medical Solutions USA, Inc.1998—
−3K022889Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL &…Siemens Medical Solutions USA, Inc.2002—
−2K031340Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 and SC 9000XL, with…Siemens Medical Solutions USA, Inc.2003—
−1K033957Infinity Modular Monitors VF4 Modifications with Scio, Models Delta, Delta XL…Draeger Medical Systems, Inc.2004—
0 (this device)K042904Infinity Kappa XLTDraeger Medical Systems, Inc.2005—
+1K060039Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc.20061
+2K070566Infinity Delta/Delta XL/ Kappa/ Gamma X XL/ Vista XL/ SC7000/SC8000/ SC9000XLDraeger Medical Systems, Inc.20076
+3K093788Infinity Acute Care System (Iacs) Monitoring SolutionDraeger Medical Systems, Inc.20104
+4K113798Infinity Acute Care System, Infinity Mcable- Masimo Rainbow SetDraeger Medical Systems, Inc.20128
+5K182543Wearable Device ; Cradle ; Small Strap, Medium Strap, Large Strap ; Multiple…Snap40, Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199030
199120
199210
199310
199620
199710
199810
199910
200010
200120
200230
200310
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200710
201010
201210
201510
201810
201920
202010
202120
202230
202330
202450
202530
202630
FIG. 1 — Lineage of K042904, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040945Modification to Infinity Explorer
Summary page 1
…MSX 2 8702300 Monitors Computers and Software, Medical LNX Predicate Device Identification: Infinity Explorer (K040945) Infinity Delta / DeltaXL / Kappa (K033957) Infinity SC 8000 (KO12016) Device Description: The Infinity Kappa XL…
Draeger Medical Systems, Inc.2004—
*K033957Infinity Modular Monitors VF4 Modifications with Scio, Models Delta, Delta XL, Kappa, SC…
Summary page 1
…ers and Software, Medical LNX Predicate Device Identification: Infinity Explorer (K040945) Infinity Delta / DeltaXL / Kappa (K033957) Infinity SC 8000 (KO12016) Device Description: The Infinity Kappa XLT is an addition to Draeger's INFINITY patient moni…
Draeger Medical Systems, Inc.2004—
*K012016Infinity SC 8000 with Advanced Communication Option IISiemens Medical Solutions USA, Inc.2001—

Also cleared against K040945: 1 other device →

What descends from it? (28)

See all 28

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K060039Infinity Delta and Kappa Series Monitors with VF6 ModificationsDraeger Medical Systems, Inc.200627

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 2 companies; a new generation was cleared every 1.2 years on median.
  • None of the 26 ancestors has a recall.
  • Of its descendants, K060039 (Draeger Medical Systems, Inc., 2006) has gone furthest, with 27 descendants of its own.
  • 1 other device also cites its predicate K040945.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The Infinity Kappa XLT is capable of measuring heart rate, respiration rate, invasive pressure, non-invasive pressure, arrhythmia, temperature, cardiac output, arterial oxygen saturation, pulse rate, apnea, ST Segment Analysis, and 12-Lead ST Segment Analysis. The device produces visual and audible alarms if any of the physiological parameters monitored vary beyond preset limits and timed or alarm recordings will be produced. The device will connect to…

Read the full statement (319 words)

The Infinity Kappa XLT is capable of measuring heart rate, respiration rate, invasive pressure, non-invasive pressure, arrhythmia, temperature, cardiac output, arterial oxygen saturation, pulse rate, apnea, ST Segment Analysis, and 12-Lead ST Segment Analysis.

The device produces visual and audible alarms if any of the physiological parameters monitored vary beyond preset limits and timed or alarm recordings will be produced. The device will connect to an R50 recorder via the Infinity Network and is capable of displaying clinical data received over a hospital information system.

Kappa XLT receives EEG signals when connected to an Infinity EEG pod.

The Infinity Trident NMT pod measures the muscle response to electrical stimulation of a peripheral nerve and when connected to a Kappa XLT transmits that information to the device.

The SCIO module sample breathing gases from adults and pediatrics. The gas module continuously measures the content of C02, N20, 02 and one of the anesthetic agents, halothane, isollurane., Enflurane, Sevoflurane and Desflurane in any mixture and communicates real time and derived gas information to Kappa XLT.

With etCO2 the Kappa XLT can measure end tidal carbon dioxide, inspired carbon dioxide, and respiration rate in either mainstream or side-stream measurement mode; and with etCO2+Respiratory Mechanics, spirometry and carbon dioxide can be monitored.

The device can interface with specific third party devices via an RS 232 connection.

The device is intended to be used in the environment where patient care is provided by Healthcare Professionals, i.e. Physicians, Nurses, and Technicians, who will determine when use of the device is indicated, based upon their professional assessment of the patient's medical condition.

The devices are intended to be used on Adult, Pediatric and Neonatal populations, with the exception of the parameter Cardiac Output, ST Segment Analysis, and arrhythmia which are intended for use in the adult and pediatric populations.

MRI Compatibility Statement:

The Infinity Kappa XLT is not compatible for use in a MRI magnetic field.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042904: Infinity Kappa XLT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042904

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026