510(k) Report

510(k) · Cleared

Cleared

Datex-Ohmeda S/5 PSM Module, (Consisting of E-PSM and E-PSMP Modules) and Accessories

K043551510(k) TraditionalCleared Feb 18, 200557-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Datex-Ohmeda · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Feb 18, 2005 as substantially equivalent to K041772 (Datex-Ohmeda, 2004) after a 57-day review. Its family tree reaches back 1 generation to 2004. 2 of the 17 devices in its family, counting itself, have a Class I recall. 15 later devices descend from it.

Decided
Feb 18, 2005
Review
57 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K041772 (2004). 15 later devices descend from it, 1 citing it directly. 2 of the 17 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2006: 1 descendant cleared2012: 1 descendant cleared2010: 1 descendant cleared, 1 with a Class I recall12025: 2 descendants cleared2013: 3 descendants cleared2014: 1 descendant cleared, 1 with a Class I recall12015: 2 descendants cleared2020: 1 descendant cleared2017: 1 descendant cleared2022: 1 descendant cleared2024: 1 descendant clearedK041772 · Datex-Ohmeda Prestn.01 Module (Model Family M-Prestn.01) and Accessories · Datex-Ohmeda · 2004200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants, 1 with a Class I recall13 generations forward: 4 descendants4 generations forward: 1 descendant, 1 with a Class I recall15 generations forward: 2 descendants6 generations forward: 2 descendants7 generations forward: 1 descendant8 generations forward: 2 descendants K041772 · Datex-Ohmeda Prestn.01 Module (Model Family M-Prestn.01) and Accessories · Datex-Ohmeda · 20040+5
  1. Root · 1 generation backK041772 Datex-Ohmeda Prestn.01 Module (Model Family M-Prestn.01) and…Datex-Ohmeda · 2004
  2. This deviceK043551 Datex-Ohmeda S/5 PSM Module, (Consisting of E-PSM and E-PSMP…Datex-Ohmeda · 2005
  3. Descendant · cites it directly · 14 of its ownK062576 Datex-Ohmeda S/5 E-PSM (P) Module (Consisting of E-PSM, E-PSMP and…GE Healthcare · 2006
  4. Descendant · 2 generations on · 10 of its ownK120598 Procare Monitor B40Ge Medical Systems China Co., Ltd. · 2012 · Recalled
  5. Descendant · 3 generations on · 8 of its ownK130584 Monitor B40Ge Medical Systems China Co., Ltd. · 2013 · Recalled
  6. Descendant · 4 generations on · 7 of its ownK133576 Monitor B40Ge Medical Systems China Co., Ltd. · 2014 · Recalled (Class I)
  7. Descendant · 5 generations on · 5 of its ownK151063 Monitor B40Ge Medical Systems China Co., Ltd. · 2015 · Recalled

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2006: 12010: 12012: 12013: 32014: 12015: 22017: 12020: 12022: 12024: 12025: 2
2006high 3 (2013) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 15 · See all
  • K062576Datex-Ohmeda S/5 E-PSM (P) Module (Consisting of E-PSM, E-PSMP and E-Intpsm Modules) and…GE Healthcare · 2006 · cites it directly14descendants
  • K120598Procare Monitor B40Ge Medical Systems China Co., Ltd. · 2012 · 2 generations on10descendants
  • K130584Monitor B40Ge Medical Systems China Co., Ltd. · 2013 · 3 generations on8descendants
  • K133576Monitor B40Ge Medical Systems China Co., Ltd. · 2014 · 4 generations on7descendants
  • K151063Monitor B40Ge Medical Systems China Co., Ltd. · 2015 · 5 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K041772Datex-Ohmeda Prestn.01 Module (Model Family M-Prestn.01) and AccessoriesDatex-Ohmeda2004—
0 (this device)K043551Datex-Ohmeda S/5 PSM Module, (Consisting of E-PSM and E-PSMP Modules) and…Datex-Ohmeda2005—
+1K062576Datex-Ohmeda S/5 E-PSM (P) Module (Consisting of E-PSM, E-PSMP and E-Intpsm…GE Healthcare2006—
+2K120598Procare Monitor B40Ge Medical Systems China Co., Ltd.20122
+3K130584Monitor B40Ge Medical Systems China Co., Ltd.20132
+4K133576Monitor B40Ge Medical Systems China Co., Ltd.2014Class I
+5K151063Monitor B40Ge Medical Systems China Co., Ltd.20151

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
201011
201210
201330
201411
201520
201710
202010
202210
202410
202520
FIG. 1 — Lineage of K043551, 2004–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041772Datex-Ohmeda Prestn.01 Module (Model Family M-Prestn.01) and Accessories
Summary page 2
…2 Respiration. The intended use for the modified device is the same as the predicate, Datex-Ohmeda M-PRESTN..0I module and accessories (K041772). The indications for use are also the same. There has been no change to the basic technology fiom the predicate. The Date…
Datex-Ohmeda2004—

Also cleared against K041772: 1 other device →

What descends from it? (15)

See all 15

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K062576Datex-Ohmeda S/5 E-PSM (P) Module (Consisting of E-PSM, E-PSMP and E-Intpsm Modules) and…GE Healthcare200614

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K093881Trusignal SPO2 Finger Sensor, Trusignal SPO2 Ear Sensor, Trusignal SPO2 Wrap SensorGE Healthcare Finland Oy · 2010 · 2 generations on · ◆ in the 2010 descendants bar of FIG. 14 Class I recalls
  • K133576Monitor B40Ge Medical Systems China Co., Ltd. · 2014 · 4 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K062576 (GE Healthcare, 2006) has gone furthest, with 14 descendants of its own.
  • 1 other device also cites its predicate K041772.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The Datex-Ohmeda S/5 PSM module (consisting of E-PSM and E-PSMP modules) and accessories are indicated for monitoring of hemodynamic parameters of all hospital patients. The hemodynamic parameters of the module comprise ECG (including ST-segment and arrhythmia), Impedance respiration, NIBP, Temperature, SpO₂ (including monitoring during conditions of clinical patient motion), and invasive blood pressure.

Impedance Respiration measurement is indicated for patients ages 3 and up.

The NIBP measurement is indicated for patients who weigh 5kg (11 lb.) and up.

The device is indicated for use by qualified medical personnel only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K043551: Datex-Ohmeda S/5 PSM Module, (Consisting of E-PSM and E-PSMP Modules) and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K043551

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026