K050860510(k) TraditionalCleared Jun 21, 200577-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Datex-Ohmeda, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Jun 21, 2005 as substantially equivalent to K992608 (Drager, Inc., 1999) and 2 other predicates after a 77-day review. Its family tree reaches back 4 generations to 1991. 1 of the 13 devices in its family, counting itself, has a Class I recall.

Decided
Jun 21, 2005
Review
77 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
3

Its longest line of descent runs back 4 generations to K902859 (1991). 12 ancestors in all. No later device cites it as a predicate yet. 1 of the 13 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 1999: 1 other ancestor2003: 1 other ancestor, 1 with a Class I recall11998: 2 other ancestors1996: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestorsK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK961687 · EVITA 4 · Drager, Inc. · 1996K970165 · Evita 2 Dura · Drager, Inc. · 1997K041775 · GE Datex-Ohmeda Engstrom Carestation · Datex-Ohmeda, Inc. · 20041990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor, 1 with a Class I recall13 generations back: 6 other ancestors K041775 · GE Datex-Ohmeda Engstrom Carestation · Datex-Ohmeda, Inc. · 2004K970165 · Evita 2 Dura · Drager, Inc. · 1997K961687 · EVITA 4 · Drager, Inc. · 1996K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled0
  1. Root · 4 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 3 generations backK961687 EVITA 4Drager, Inc. · 1996
  3. 2 generations backK970165 Evita 2 DuraDrager, Inc. · 1997
  4. 1 generation backK041775 GE Datex-Ohmeda Engstrom CarestationDatex-Ohmeda, Inc. · 2004
  5. This deviceK050860 GE Datex-Ohmeda Centiva/5 VentilatorDatex-Ohmeda, Inc. · 2005

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K902859Servo Ventilator 300Siemens Life Support Systems19913
−3K961687EVITA 4Drager, Inc.1996—
−2K970165Evita 2 DuraDrager, Inc.1997—
−1K041775GE Datex-Ohmeda Engstrom CarestationDatex-Ohmeda, Inc.2004—
0 (this device)K050860GE Datex-Ohmeda Centiva/5 VentilatorDatex-Ohmeda, Inc.2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199610
199820
199910
200311
FIG. 1 — Lineage of K050860, 1991–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992608Atc Option for Evita 2 Dura and Evita 4
Summary page 1
…following currently marketed device: Drager Evita 4- Class 1I - 21CFR868.5895, which has been the subject of a cleared 5 10(k) with FDA log number K992608. Drager Evita 2- Class II - 21CFR868.5895, which has been the subject of a cleared 5 10(k) with FDA log nu…
Drager, Inc.1999—
*K970165Evita 2 Dura
Summary page 1
…with FDA log number K992608. Drager Evita 2- Class II - 21CFR868.5895, which has been the subject of a cleared 5 10(k) with FDA log number K970165. GE Datex-Ohmeda Engstrom Carestation -Class IL- 21CFR868.5895, which has been the subject of several clea…
Drager, Inc.1997—
*K041775GE Datex-Ohmeda Engstrom Carestation
Summary page 1
…GE Datex-Ohmeda Engstrom Carestation -Class IL- 21CFR868.5895, which has been the subject of several cleared 51 0(k)s, most recently with FDA log number K041775. The Centiva/5 is a flexible, intuitive and simple to operate critical care ventilator. It offers a configurable and compact…
Datex-Ohmeda, Inc.2004—

Also cleared against K992608: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K023366Datex-Ohmeda 7900 Ventilator EnhancementsDatex-Ohmeda, Inc. · 2003 · 2 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 5.6 years on median.
  • 4 of the 12 ancestors have a recall of any class; 1 has a Class I recall.
  • 4 other devices also cite its predicate K992608.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The GE Datex-Ohmeda Centiva/5 Critical Care Ventilator is designed as a critical care ventilator for adult to pediatric patients. It provides volume control, pressure volume, bi-level and pressure support ventilation (PSV), Continuous Positive Pressure (CPAP) and PSV with apnea back-up ventilation modes. It incorporates integrated airway pressure, patient flow, tidal volume, minute volume, peak pressure, PEEP, rate and FlO2 monitoring.

The system is designed for facility use, including within-facility transport, and should only be used under the orders of a clinician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K050860: GE Datex-Ohmeda Centiva/5 Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050860

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026