Dimension Vista Carbon Dioxide, Creatinine and Lactate Dehydrogenase Flex Reagent Cartridge

K061238510(k) SpecialCleared May 25, 200622-day reviewClass II21 CFR 862.1160Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dade Behring, Inc. · KHS Enzymatic, Carbon-Dioxide

Cleared on May 25, 2006 as substantially equivalent to K010206 (Dade Behring, Inc., 2001) and 2 other predicates after a 22-day review. Its family tree reaches back 1 generation to 1986. 1 later device descends from it. It has been recalled once.

Decided
May 25, 2006
Review
22 days
Class
Class II
Product code
KHS
Recalls
1
Predicates
3

Its longest line of descent runs back 1 generation to K860021 (1986). 3 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1992: 1 other ancestor2014: 1 descendant clearedK860021 · Dimension (TM) Clinical Chemistry System · E.I. Dupont DE Nemours & Co., Inc. · 1986 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 1 descendant K860021 · Dimension (TM) Clinical Chemistry System · E.I. Dupont DE Nemours & Co., Inc. · 1986 · recalled0
  1. Root · 1 generation backK860021 Dimension (TM) Clinical Chemistry SystemE.I. Dupont DE Nemours & Co., Inc. · 1986 · Recalled
  2. This deviceK061238 Dimension Vista Carbon Dioxide, Creatinine and Lactate Dehydrogenase…Dade Behring, Inc. · 2006
  3. Descendant · cites it directly · 0 of its ownK133728 Dimension Vista Creatinine (CRE2) Flex Reagent CartridgeSiemens Healthcare Diagnostics, Inc. · 2014

Most influential descendants

Showing 1 of 1 · See all
  • K133728Dimension Vista Creatinine (CRE2) Flex Reagent CartridgeSiemens Healthcare Diagnostics, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K860021Dimension (TM) Clinical Chemistry SystemE.I. Dupont DE Nemours & Co., Inc.19861
0 (this device)K061238Dimension Vista Carbon Dioxide, Creatinine and Lactate Dehydrogenase Flex…Dade Behring, Inc.2006—
+1K133728Dimension Vista Creatinine (CRE2) Flex Reagent CartridgeSiemens Healthcare Diagnostics, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
FIG. 1 — Lineage of K061238, 1986–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KHS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010206Dimension Enzymatic Carbonate (ECO2) Flex Method, Catalog DF137
Summary page 1
…class Code Dimension Vista TM Dimension® ECO2 C02 Flex® reagent Flex® reagent K010206 II 862.1160 KHS cartridge cartridge Dimension Vista"" Dimension® CREA CREA Flex® reagent…
Dade Behring, Inc.2001—
*K925668Creatinine Meth for Use on the Dimension Clin Chem
Summary page 1
…K010206 II 862.1160 KHS cartridge cartridge Dimension Vista"" Dimension® CREA CREA Flex® reagent Flex® reagent K925668 II 862.1125 CGX cartridge cartridge Dimension Vista TM Dimension® LDH LDH Flex® reagent F…
E.I. Dupont DE Nemours & Co., Inc.19923
*K860021Dimension (TM) Clinical Chemistry System
Summary page 1
…K925668 II 862.1125 CGX cartridge cartridge Dimension Vista TM Dimension® LDH LDH Flex® reagent Flex® reagent K860021 II 862.1440* CFJ cartridge cartridge I * Not exempt from premarket notification per 862.…
E.I. Dupont DE Nemours & Co., Inc.19861

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133728Dimension Vista Creatinine (CRE2) Flex Reagent CartridgeSiemens Healthcare Diagnostics, Inc.20140

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 15, 2015Class IIZ-2741-2015Device DesignSiemens has confirmed that the Dimension CREA and Dimension Vista CREA may produce falsely depressed results up to - 12.7% and -22% respectively, for a creatinine concentration of 1.5 mg/dL when hemolysis exceeds 200 mg/dL and 300 mg/dL…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K133728 (Siemens Healthcare Diagnostics, Inc., 2014) has gone furthest, with 0 descendants of its own.

How does its category compare?

All KHS devices

KHS Enzymatic, Carbon-Dioxide: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KHS

1in 2017

2007: 22008: 12009: 12010: 32011: 12012: 22013: 22014: 12016: 12017: 1
2007high 3 (2010) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KHS

143in 2010

2010: 143 days median
2007high 143 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KHS

1in 2025

2013: 12019: 12023: 12025: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KHS

40in 2025

2008: 22009: 142011: 52012: 32013: 22014: 62015: 12016: 42017: 72018: 152019: 352020: 312021: 142022: 102023: 252024: 302025: 40
2007high 40 (2025) · low 0 (2007)2025

MAUDE reports naming product code KHS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—02
20091—014
2010314300
20111—05
20122—03
20132—12
20141—06
20150—01
20161—04
20171—07
20180—015
20190—135
20200—031
20210—014
20220—010
20230—125
20240—030
20250—140
20260—0—

What is it indicated for?

The Dimension VistaTM Carbon Dioxide (CO2) Flex® reagent cartridge is a device intended to measure carbon dioxide in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid-base balance. The Dimension VistaTM Creatinine (CREA) Flex® reagent cartridge is a device intended to measure creatinine levels in serum, plasma and urine. Creatinine…

Read the full statement (156 words)

The Dimension VistaTM Carbon Dioxide (CO2) Flex® reagent cartridge is a device intended to measure carbon dioxide in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid-base balance.

The Dimension VistaTM Creatinine (CREA) Flex® reagent cartridge is a device intended to measure creatinine levels in serum, plasma and urine. Creatinine measurements are used in the diagnosis and treatment of renal diseases, in monitoring renal dialysis, and as a calculation basis for measuring other urine analytes.

The Dimension VistaTM Lactate dehydrogenase (LDH) Flex® reagent cartridge is a device intended to measure the activity of the enzyme lactate dehydrogenase in serum and plasma. Lactate dehydrogenase measurements are used in the diagnosis and treatment of liver diseases such as acute viral hepatitis, cirrhosis, and metastatic carcinoma of the liver, cardiac diseases such as myocardial infarction, and tumors of the lung or kidneys.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061238: Dimension Vista Carbon Dioxide, Creatinine and Lactate Dehydrogenase Flex Reagent Cartridge.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K061238

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026