510(k) Report

510(k) · Cleared

Cleared

I-PAD

K062970510(k) TraditionalCleared Jan 22, 2008480-day reviewClass III21 CFR 870.5310

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cu Medical Systems, Inc. · MKJ Automated External Defibrillators (Non-Wearable)

Cleared on Jan 22, 2008 as substantially equivalent to K020715 (Philips Medical Systems, 2002) and 2 other predicates after a 480-day review. Its family tree reaches back 2 generations to 1996.

Decided
Jan 22, 2008
Review
480 days
Class
Class III
Product code
MKJ
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K955628 (1996). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK955628 Fore Runner External Defibrillator/Defibrillator PadsHeartstream, Inc. · 1996
  2. 1 generation backK013896 Sentry Semiautomatic External Defibrillator; External Defibrillation…Defibtech, LLC · 2002 · Recalled
  3. This deviceK062970 I-PADCu Medical Systems, Inc. · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K955628Fore Runner External Defibrillator/Defibrillator PadsHeartstream, Inc.1996—
−1K013896Sentry Semiautomatic External Defibrillator; External Defibrillation Pads…Defibtech, LLC20025
0 (this device)K062970I-PADCu Medical Systems, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200220
FIG. 1 — Lineage of K062970, 1996–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MKJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020715Philips M5066A and M5068A
Summary page 1
…y the following: Device Name Manufacturer 5 10(K) Number Philips HeartStart OnSite Philips Medical Systems K020715 Philips HeartStart FR2+ Philips Medical Systems K013425 Defibtech Sentry DDU-100A Defibtech, LLC…
Philips Medical Systems200212
*K013425Heartstream/Heartstart FR2 Aed Ecg Cable, Models M3860A, M3861A, M3840A, M3841A
Summary page 1
…5 10(K) Number Philips HeartStart OnSite Philips Medical Systems K020715 Philips HeartStart FR2+ Philips Medical Systems K013425 Defibtech Sentry DDU-100A Defibtech, LLC K013896 The shock delivered by the device is in the form of…
Philips Medical Systems200210
*K013896Sentry Semiautomatic External Defibrillator; External Defibrillation Pads (Electrodes)…
Summary page 1
…stems K020715 Philips HeartStart FR2+ Philips Medical Systems K013425 Defibtech Sentry DDU-100A Defibtech, LLC K013896 The shock delivered by the device is in the form of a Biphasic Truncated Exponential which has characteristics and results that…
Defibtech, LLC20025

Also cleared against K020715: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 5.8 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • 6 other devices also cite its predicate K020715.

How does its category compare?

All MKJ devices

MKJ Automated External Defibrillators (Non-Wearable): FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · MKJ

48in 2025

2007: 72008: 132009: 82010: 42011: 112012: 102013: 72014: 112015: 62017: 42018: 202019: 252020: 522021: 412022: 192023: 242024: 272025: 482026 (partial year): 31
2007high 52 (2020) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MKJ

156in 2015

2007: 69 days median2008: 141 days median2009: 165 days median2010: 250 days median2011: 36 days median2012: 197 days median2013: 191 days median2014: 196 days median2015: 156 days median
2007high 250 (2010) · low 36 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MKJ

1in 2025

2007: 122008: 242009: 372010: 352011: 72012: 5, 1 Class I2013: 42014: 24, 15 Class I2015: 12016: 2, 1 Class I2017: 6, 4 Class I2018: 32019: 6, 2 Class I2020: 22021: 42022: 32023: 112024: 52025: 12026 (partial year): 3
2007high 37 (2009) · low 1 (2015)2026

Class I (23 since 2007) Class II/III not classified

Adverse event reports per year · MKJ

13,315in 2025

2007: 3,9582008: 4,7522009: 6,7822010: 7,3992011: 8,1702012: 9,7322013: 14,9552014: 15,3992015: 16,1292016: 17,0622017: 16,6842018: 16,5912019: 16,8612020: 16,1972021: 16,3002022: 14,8672023: 13,7662024: 15,1092025: 13,315
2007high 17,062 (2016) · low 3,958 (2007)2025

MAUDE reports naming product code MKJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007769123,958
200813141244,752
20098165376,782
20104250357,399
2011113678,170
2012101975 (1)9,732
20137191414,955
20141119624 (15)15,399
20156156116,129
20160—2 (1)17,062
20174—6 (4)16,684
201820—316,591
201925—6 (2)16,861
202052—216,197
202141—416,300
202219—314,867
202324—1113,766
202427—515,109
202548—113,315
202631—3—

What is it indicated for?

The i-PAD NF1200 is used to treat a person suffering from sudden cardiac arrest (SCA)

and who exhibits symptoms of

* No movement and no response when shaken

* No normal breathing

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062970: I-PAD.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062970

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026