510(k) Report

510(k) · Cleared

Cleared

Eyetracker/Ideas

K070670510(k) TraditionalCleared Sep 18, 2007190-day reviewClass II21 CFR 882.1460

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

S.A. Instrumentation Difra · GWN Nystagmograph

Cleared on Sep 18, 2007 as substantially equivalent to K991497 (Ics Medical Corp., 1999) and 3 other predicates after a 190-day review. Its family tree reaches back 1 generation to 1997.

Decided
Sep 18, 2007
Review
190 days
Class
Class II
Product code
GWN
Recalls
None
Predicates
5

Its longest line of descent runs back 1 generation to K964325 (1997). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2001: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestorK964325 · Visualeyes: Video Eye Monitor · Micromedical Technologies, Inc. · 19971996199820002002200420062008
Other ancestors, by generation 1 generation back: 3 other ancestors K964325 · Visualeyes: Video Eye Monitor · Micromedical Technologies, Inc. · 19970
  1. Root · 1 generation backK964325 Visualeyes: Video Eye MonitorMicromedical Technologies, Inc. · 1997
  2. This deviceK070670 Eyetracker/IdeasS.A. Instrumentation Difra · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K964325Visualeyes: Video Eye MonitorMicromedical Technologies, Inc.1997—
0 (this device)K070670Eyetracker/IdeasS.A. Instrumentation Difra2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
199910
200110
FIG. 1 — Lineage of K070670, 1997–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWN device

  1. #1 K260566 SMARTVERTIGO™ Vestibular Assessment Systemscore 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K991497Ics Medical Chartr Eng/VNG Diagnostic System
Summary page 2
…mcl il, , 1(1I rfl10 *w di; bh Substantial Equivalency: The device is substantially equivalent to: **the CHARTR ENG!VNG Diagnostic System (K99 1497) marketed by ICS Medical Corporation *.the ENGPLUS (K010059) marketed by WesternSystem Research,lInc. the V…
Ics Medical Corp.1999—
*K010059Engplus
Summary page 2
…ency: The device is substantially equivalent to: **the CHARTR ENG!VNG Diagnostic System (K99 1497) marketed by ICS Medical Corporation *.the ENGPLUS (K010059) marketed by WesternSystem Research,lInc. the VISUAL EYES (K964325) marketed by Micromedical Technologies, Inc. For its a…
Western Systems Research, Inc.2001—
*K964325Visualeyes: Video Eye Monitor
Summary page 2
…Diagnostic System (K99 1497) marketed by ICS Medical Corporation *.the ENGPLUS (K010059) marketed by WesternSystem Research,lInc. the VISUAL EYES (K964325) marketed by Micromedical Technologies, Inc. For its ability to record torsional movements, the device is substantially equivalen…
Micromedical Technologies, Inc.1997—
*K982103Ulmer (VNG) Video Nystagmograph
Summary page 2
…by Micromedical Technologies, Inc. For its ability to record torsional movements, the device is substantially equivalent to: **the ULMER (VNG) VIDEO NYSTAGMOGRAPH (K982 103) marketed by Synapsys, Inc. **the I-PORTAL, also known as I-PORTAL VNG, part of the NEURO- OTOLOGIC TEST CE…
Synapsys, Inc.1998—
Kept off the family treeK781268FDA’s K781268 is Chair, Vestibular, Rotary, Comput.
Our OCR of the scanned summary read K781268, FDA’s number for Chair, Vestibular, Rotary, Comput. (Contraves). Its FDA name has none of the distinctive words the summary uses for the device it names, “I-PORTAL, also known as I-PORTAL VNG, part of the NEURO-OTOLOGIC…”. Kept off the family tree.
Summary page 2
…VNG) VIDEO NYSTAGMOGRAPH (K982 103) marketed by Synapsys, Inc. **the I-PORTAL, also known as I-PORTAL VNG, part of the NEURO- OTOLOGIC TEST CENTER (K78 1268) marketed by Neuro Kinetics, Inc. Description of the device: The device is a PC-based system for measuring, recording and displa…
Contraves1978—

Also cleared against K991497: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 4 ancestors has a recall.
  • 4 other devices also cite its predicate K991497.

How does its category compare?

All GWN devices

GWN Nystagmograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GWN

3in 2025

2007: 22008: 12009: 12013: 32015: 32016: 22017: 42018: 32019: 12020: 22023: 12025: 32026 (partial year): 1
2007high 4 (2017) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWN

203in 2025

2013: 88 days median2015: 165 days median2017: 160 days median2018: 87 days median2025: 203 days median
2007high 203 (2025) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWN

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWN

1in 2025

2012: 22018: 12019: 52021: 12022: 12023: 32024: 42025: 1
2007high 5 (2019) · low 0 (2007)2025

MAUDE reports naming product code GWN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20091—00
20100—00
20110—00
20120—02
201338810
20140—00
2015316500
20162—00
2017416000
201838701
20191—05
20202—00
20210—01
20220—01
20231—03
20240—04
2025320301
20261—0—

What is it indicated for?

The device is intended to measure, record and display the movements of the eyeballs during their involuntary movements (nystagmus) and while testing the patient's vestibular function.

The device is for prescription use only and it is intended for use by qualified medical personnel trained in the use of nystagmographs. This device provides no diagnoses nor does it provide diagnostic recommendations.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K070670: Eyetracker/Ideas.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K070670

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026