510(k) · Cleared
ClearedTrabecular Metal Vertebral Body Replacement (VBR), Model# 06-115, 06-155
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Zimmer Trabecular Metal Technology · MQP Spinal Vertebral Body Replacement Device
Cleared on Aug 31, 2007 after a 165-day review. The FDA summary names no predicate by number. 506 later devices descend from it.
- Decided
- Aug 31, 2007
- Review
- 165 days
- Class
- Class II
- Product code
- MQP
- Recalls
- None
- Predicates
- 0
506 later devices descend from it, 2 citing it directly.
- This deviceK070754 Trabecular Metal Vertebral Body Replacement (VBR), Model# 06-115…Zimmer Trabecular Metal Technology · 2007
- Descendant · cites it directly · 505 of its ownK103033 Trabecular Metal Fusion Device Model 06-101-Xxxxx, 06-102-Xxxxx and…Zimmer Trabecular Metal Technology · 2011
- Descendant · 2 generations on · 476 of its ownK113561 TM Ardis Interbody System TM Ardis Interbody System InstrumenationZimmer Trabecular Metal Technology · 2012 · Recalled
- Descendant · 3 generations on · 459 of its ownK150481 Cascadia Interbody SystemK2m, Inc. · 2015 · Recalled
- Descendant · 4 generations on · 315 of its ownK160125 Cascadia Interbody SystemK2m · 2016
- Descendant · 4 generations on · 276 of its ownK163230 NuVasive Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017
Showing 5 of 506 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 506 · See all- K103033Trabecular Metal Fusion Device Model 06-101-Xxxxx, 06-102-Xxxxx and 08-100-XxxxxZimmer Trabecular Metal Technology · 2011 · cites it directly505descendants
- K113561TM Ardis Interbody System TM Ardis Interbody System InstrumenationZimmer Trabecular Metal Technology · 2012 · 2 generations on476descendants
- K150481Cascadia Interbody SystemK2m, Inc. · 2015 · 3 generations on459descendants
- K160125Cascadia Interbody SystemK2m · 2016 · 4 generations on315descendants
- K163230NuVasive Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017 · 4 generations on276descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K070754 | Trabecular Metal Vertebral Body Replacement (VBR), Model# 06-115, 06-155 | Zimmer Trabecular Metal Technology | 2007 | — |
| +1 | K103033 | Trabecular Metal Fusion Device Model 06-101-Xxxxx, 06-102-Xxxxx and 08-100-Xxxxx | Zimmer Trabecular Metal Technology | 2011 | — |
| +2 | K113561 | TM Ardis Interbody System TM Ardis Interbody System Instrumenation | Zimmer Trabecular Metal Technology | 2012 | 2 |
| +3 | K150481 | Cascadia Interbody System | K2m, Inc. | 2015 | 3 |
| +4 | K160125 | Cascadia Interbody System | K2m | 2016 | — |
| +4 | K163230 | NuVasive Modulus XLIF Interbody System | Nu Vasive, Incorporated | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 3 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 3 | 0 |
| 2015 | 2 | 0 |
| 2016 | 7 | 0 |
| 2017 | 21 | 0 |
| 2018 | 28 | 0 |
| 2019 | 33 | 0 |
| 2020 | 53 | 0 |
| 2021 | 47 | 0 |
| 2022 | 52 | 0 |
| 2023 | 72 | 0 |
| 2024 | 76 | 0 |
| 2025 | 57 | 0 |
| 2026 | 50 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQP device
- #1 K261810 Vertiwedge® Intraosseous Systemscore 18.1 · 22 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (506)
See all 5062 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K103033 (Zimmer Trabecular Metal Technology, 2011) has gone furthest, with 505 descendants of its own.
How does its category compare?
All MQP devicesMQP Spinal Vertebral Body Replacement Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · MQP
4in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · MQP
187in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQP
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQP
168in 2025
MAUDE reports naming product code MQP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 30 | 107 | 2 | 61 |
| 2008 | 17 | 47 | 0 | 76 |
| 2009 | 11 | 115 | 14 | 111 |
| 2010 | 6 | 174 | 2 | 166 |
| 2011 | 8 | 237 | 1 | 121 |
| 2012 | 7 | 82 | 2 | 141 |
| 2013 | 3 | 90 | 0 | 207 |
| 2014 | 5 | 125 | 0 | 216 |
| 2015 | 8 | 126 | 0 | 258 |
| 2016 | 0 | — | 0 | 129 |
| 2017 | 9 | 97 | 0 | 141 |
| 2018 | 6 | 152 | 0 | 130 |
| 2019 | 8 | 93 | 0 | 117 |
| 2020 | 3 | 103 | 15 | 157 |
| 2021 | 0 | — | 0 | 208 |
| 2022 | 1 | — | 1 | 137 |
| 2023 | 1 | — | 0 | 71 |
| 2024 | 4 | 187 | 0 | 98 |
| 2025 | 0 | — | 0 | 168 |
| 2026 | 3 | 102 | 0 | — |
What is it indicated for?
The Trabecular Metal Vertebral Body Replacement System is comprised of vertebral body replacement devices intended for use in the thoracolumbar spine (TI-L5) to replace a collapsed, damaged or unstable vertebral body due to tumor or trauma (i.e., fracture). The Trabecular Metal Vertebral Body Replacement is intended for use with supplemental internal spinal fixation systems. The Trabecular Metal Vertebral Body Replacement may be used with bone graft.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070754 · printed Nov 6, 2026
Cite this page
510(k) Report. “K070754: Trabecular Metal Vertebral Body Replacement (VBR), Model# 06-115, 06-155.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070754
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026