510(k) Report

510(k) · Cleared

Cleared

Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU05 and L-CICU05A Software

K071020510(k) SpecialCleared Jun 18, 200769-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Healthcare · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Jun 18, 2007 as substantially equivalent to K022740 (Datex-Ohmeda, 2002) after a 69-day review. Its family tree reaches back 2 generations to 2000.

Decided
Jun 18, 2007
Review
69 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K002158 (2000). No later device cites it as a predicate yet.

  1. Root · 2 generations backK002158 S/5 Compact Critical Care Monitor with S-00C03 or S-00C04 SoftwareDatex-Ohmeda, Inc. · 2000
  2. 1 generation backK022740 Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU02 &…Datex-Ohmeda · 2002 · Recalled
  3. This deviceK071020 Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU05 and…GE Healthcare · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002158S/5 Compact Critical Care Monitor with S-00C03 or S-00C04 SoftwareDatex-Ohmeda, Inc.2000—
−1K022740Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU02 & L-CICU02A…Datex-Ohmeda20022
0 (this device)K071020Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU05 and L-CICU05A…GE Healthcare2007—
FIG. 1 — Lineage of K071020, 2000–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022740Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU02 & L-CICU02A Software
Summary page 2
…and L-CICU05A software is substantially equivalent to the predicate Datex-Ohmeda S/5TM Compact Critical Care Monitor with L-CICU02 and L-CICU02A software (K022740). DEVICE DESCRIPTION as required by 807.92(a)(4) The two software options for the S/5 TM Compact Critical Care Monitor…
Datex-Ohmeda20022

Also cleared against K022740: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 4.6 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • 1 other device also cites its predicate K022740.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The S/5TM Compact Critical Care Monitor with L-CICU05 and L-CICU05A software is indicated for monitoring of hemodynamic (including arrhythmia and ST-segment analysis), respiratory, ventilatory, gastrointestinal/regional perfusion, Bispectral index (BIS), and neurophysiological status of all hospital patients. The S/5TM Compact Critical Care Monitor with L-CICU05 and L-CICU05A software when using BIS is for monitoring the state of the brain by data…

Read the full statement (101 words)

The S/5TM Compact Critical Care Monitor with L-CICU05 and L-CICU05A software is indicated

for monitoring of hemodynamic (including arrhythmia and ST-segment analysis), respiratory,

ventilatory, gastrointestinal/regional perfusion, Bispectral index (BIS), and neurophysiological

status of all hospital patients.

The S/5TM Compact Critical Care Monitor with L-CICU05 and L-CICU05A software when using BIS is for monitoring the state of the brain by data acquisition and processing of electroencephalograph signals and may be used as an aid in monitoring the effects of certain anesthetic agents.

The S/5TM Compact Critical Care Monitor with L-CICU05 and L-CICU05A software is indicated for use by qualified medical personnel only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K071020: Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU05 and L-CICU05A Software.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K071020

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026