510(k) Report

510(k) · Cleared

Cleared

Belimed Steam Sterilizer Model Top 5000 Series 24

K072087510(k) TraditionalCleared Oct 5, 200767-day reviewClass II21 CFR 880.6880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Belimed Sauter AG · FLE Sterilizer, Steam

Cleared on Oct 5, 2007 as substantially equivalent to K021223 (Sauter AG, 2002) and 1 other predicate after a 67-day review. Its family tree reaches back 2 generations to 1998.

Decided
Oct 5, 2007
Review
67 days
Class
Class II
Product code
FLE
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K964332 (1998). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2004: 1 other ancestorK964332 · Eagle Century Steam Sterilizer · Amsco Intl., Inc. · 1998 · recalledK021223 · Belimed Steam Sterilizer, Model Top 5000 · Sauter AG · 20021996199820002002200420062008
Other ancestors, by generation 1 generation back: 1 other ancestor K021223 · Belimed Steam Sterilizer, Model Top 5000 · Sauter AG · 2002K964332 · Eagle Century Steam Sterilizer · Amsco Intl., Inc. · 1998 · recalled0
  1. Root · 2 generations backK964332 Eagle Century Steam SterilizerAmsco Intl., Inc. · 1998 · Recalled
  2. 1 generation backK021223 Belimed Steam Sterilizer, Model Top 5000Sauter AG · 2002
  3. This deviceK072087 Belimed Steam Sterilizer Model Top 5000 Series 24Belimed Sauter AG · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K964332Eagle Century Steam SterilizerAmsco Intl., Inc.19982
−1K021223Belimed Steam Sterilizer, Model Top 5000Sauter AG2002—
0 (this device)K072087Belimed Steam Sterilizer Model Top 5000 Series 24Belimed Sauter AG2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K072087, 1998–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021223Belimed Steam Sterilizer, Model Top 5000
Summary page 1
…Sterilizer- Class II,as listed per 21 CFR 880.6880 Predicate Devices: Belimned Steam Sterilizer TOP 5000 Series 9 - 18 (K021 223) and Series 4-8 (KC33538) DEVICE DESCRIPTION: The Belimed Steam Sterilizers TOP 5000 Series 24…
Sauter AG2002—
*K033538Belimed Steam Sterilizer Top 5000, Series 4 - 8
Summary page 1
…: * Larger chamber size (chamber height increased) * Vacuum-pump power was increased according to larger chamber volume. * Improved functionality (as done for series 4-8 K033538) CLINICAL DATA No clinical data isrequired for this device classification submission INDICATIONS FOR USE: The Belimed Steam Ste…
Sauter AG2004—

Also cleared against K021223: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 5.3 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K021223.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The Belimed Steam Sterilizer TOP 5000, series 24, is designed for sterilization of non porous and porous heat and moisture-stable materials used in healthcare facilities.

The Belimed Steam Sterilizer TOP 5000, series 24, is equipped with the following factory-programmed Sterilization cycles and cycle values (Table 1).

The Belimed Steam Sterilizer TOP5000, series 24, is available as a single door prevacuum or a double door prevacuum version.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072087: Belimed Steam Sterilizer Model Top 5000 Series 24.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K072087

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026