510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Eagle Century Steam Sterilizer

K964332510(k) TraditionalCleared Jun 1, 1998579-day reviewClass II21 CFR 880.6880Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Amsco Intl., Inc. · FLE Sterilizer, Steam

Cleared on Jun 1, 1998 after a 579-day review. The FDA summary names no predicate by number. 14 later devices descend from it. It has been recalled 2 times.

Decided
Jun 1, 1998
Review
579 days
Class
Class II
Product code
FLE
Recalls
2
Predicates
0

14 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2002: 1 descendant cleared2015: 1 descendant cleared2017: 1 descendant cleared2007: 1 descendant cleared2012: 1 descendant cleared2011: 1 descendant cleared2014: 2 descendants cleared2021: 1 descendant cleared2023: 2 descendants cleared2013: 1 descendant cleared2019: 1 descendant cleared1995200020052010201520202025
  1. This deviceK964332 Eagle Century Steam SterilizerAmsco Intl., Inc. · 1998
  2. Descendant · cites it directly · 8 of its ownK030789 Amsco Century Steam SterilizerSTERIS Corporation · 2003
  3. Descendant · cites it directly · 4 of its ownK021223 Belimed Steam Sterilizer, Model Top 5000Sauter AG · 2002
  4. Descendant · 2 generations on · 3 of its ownK111223 Amsco Chimeron Small Steam SterilizerSTERIS Corporation · 2011 · Recalled
  5. Descendant · 2 generations on · 2 of its ownK120149 Skyron Integrity 215 Steam Sterilizer Skytron Integrity 215 SG Steam…Sakura Seiki Co., Ltd. · 2012
  6. Descendant · 3 generations on · 1 of its ownK221474 PRIMUS Healthcare Sterilizer (Model PSS11-HC)Primus Sterilizer Company, LLC · 2023

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2002: 12003: 12007: 12011: 12012: 12013: 12014: 22015: 12017: 12019: 12021: 12023: 2
2002high 2 (2014) · low 0 (2004)2026

Most influential descendants

Showing 5 of 14 · See all
  • K030789Amsco Century Steam SterilizerSTERIS Corporation · 2003 · cites it directly8descendants
  • K021223Belimed Steam Sterilizer, Model Top 5000Sauter AG · 2002 · cites it directly4descendants
  • K111223Amsco Chimeron Small Steam SterilizerSTERIS Corporation · 2011 · 2 generations on3descendants
  • K120149Skyron Integrity 215 Steam Sterilizer Skytron Integrity 215 SG Steam Sterilizer Sakura…Sakura Seiki Co., Ltd. · 2012 · 2 generations on2descendants
  • K221474PRIMUS Healthcare Sterilizer (Model PSS11-HC)Primus Sterilizer Company, LLC · 2023 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K964332Eagle Century Steam SterilizerAmsco Intl., Inc.1998—
+1K030789Amsco Century Steam SterilizerSTERIS Corporation2003—
+1K021223Belimed Steam Sterilizer, Model Top 5000Sauter AG2002—
+2K111223Amsco Chimeron Small Steam SterilizerSTERIS Corporation20113
+2K120149Skyron Integrity 215 Steam Sterilizer Skytron Integrity 215 SG Steam…Sakura Seiki Co., Ltd.2012—
+3K221474PRIMUS Healthcare Sterilizer (Model PSS11-HC)Primus Sterilizer Company, LLC2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200710
201110
201210
201310
201420
201510
201710
201910
202110
202320
FIG. 1 — Lineage of K964332, 1998–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (14)

See all 14

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K030789Amsco Century Steam SterilizerSTERIS Corporation20038
K021223Belimed Steam Sterilizer, Model Top 5000Sauter AG20024

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 22, 2019Class IIZ-0604-2020PackagingPotential for the incorrect pressure safety valve being included in the Preventive Maintenance (PM) kit for the 3000 Small Sterilizers.
Mar 6, 2008Not classifiedZ-2350-2008Employee errorThe firm discovered that some Eagle 3000 units may have a door post pin missing which could cause incomplete or no engagement of the radial arms into the lock rails of the door. The sterilizer is designed with switches that prevent cycle…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K030789 (STERIS Corporation, 2003) has gone furthest, with 8 descendants of its own.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The STERIS Eagle Century Steam Sterilizer is designed for efficient, sterilization of non-porous and porous, heat and moisture-stabile materials used in healthcare facilities. The Eagle Century Steam Sterilizer is available in the following configurations: 16" x 16" x 26" Single Door Gravity 16" x 16" x 26" Single Door Prevacuum 16" x 16" x 26" Double Door Gravity 16" x 16" x 26" Double Door Prevacuum 20" x 20" x 38" Single Door Gravity 20" x 20" x 38"…

Read the full statement (335 words)

The STERIS Eagle Century Steam Sterilizer is designed for efficient, sterilization of non-porous and porous, heat and moisture-stabile materials used in healthcare facilities. The Eagle Century Steam Sterilizer is available in the following configurations:

16" x 16" x 26" Single Door Gravity

16" x 16" x 26" Single Door Prevacuum

16" x 16" x 26" Double Door Gravity

16" x 16" x 26" Double Door Prevacuum

20" x 20" x 38" Single Door Gravity

20" x 20" x 38" Single Door Prevacuum

20" x 20" x 38" Double Door Gravity

20" x 20" x 38" Double Door Prevacuum

The Eagle Century Steam Sterilizer is equipped with the following factory-programmed set sterilization cycles and cycle values:

Prevacuum Configuration

CYCLES | RECOMMENDED LOADS | STERILIZE TEMP. | STERILIZE TIME | DRY TIME

FLASH | Unwrapped Instrument tray with a single instrument | 270°F (132°C) | 3 minutes | 1 minute

FLASH | Unwrapped instrument tray with non-porous multiple instruments, maximum weight 17lbs | 270°F (132°C) | 10 minutes | 1 minute

EXPRESS | Single wrapped instrument tray with a single instrument. Non-porous goods only. | 270°F (132°C) | 4 minutes | 3 minutes

PREVAC | Up to two double wrapped instrument trays, maximum weight 17lbs. Up to six fabric packs. | 270°F (132°C) | 4 minutes | 20 minutes'

'Five minute Dry Time can be used for processing a single fabric pack.

GRAVITY CONFIGURATION

CYCLES | RECOMMENDED LOADS | STERILIZE TEMP. | STERILIZE TIME | DRY TIME

FLASH | Unwrapped Instrument tray with a single instrument. | 270°F (132°C) | 3 minutes | 1 minute

FLASH | Unwrapped Instrument tray with non-porous multiple instruments, maximum weight 17lbs | 270°F (132°C) | 10 minutes | 1 minute

GRAVITY | Up to two double wrapped instrument trays, maximum weight 17lbs | 270°F (132°C) | 15 minutes | 30 minutes

GRAVITY | Fabric Packs | 250°F (121°C) | 30 minutes’ | 15 minutes

A 270°F (132°C) cycle adjusted to 25 minute Sterilize Time can be used for processing fabric packs.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K964332: Eagle Century Steam Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K964332

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026