Cor Analyzer II, Model V1.7

K072242510(k) SpecialCleared Sep 11, 200729-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rcadia Medical Imaging, Ltd. · LLZ System, Image Processing, Radiological

Cleared on Sep 11, 2007 as substantially equivalent to K061624 (Vital Images, Inc., 2006) and 1 other predicate after a 29-day review. Its family tree reaches back 10 generations to 1991. 5 later devices descend from it.

Decided
Sep 11, 2007
Review
29 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
2

Its longest line of descent runs back 10 generations to K913770 (1991). 31 ancestors in all. 5 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor1999: 2 other ancestors2002: 2 other ancestors1997: 2 other ancestors1996: 3 other ancestors2001: 4 other ancestors2000: 2 other ancestors1995: 1 other ancestor1998: 2 other ancestors1994: 2 other ancestors2011: 1 descendant cleared2013: 1 descendant cleared2023: 2 descendants cleared2025: 1 descendant clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK063548 · Cor Analyzer 1, Version 1.4 · Rcadia Medical Imaging, Ltd. · 20071990200020102020
  1. Root · 10 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 6 generations between
  3. 3 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  4. 2 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  5. 1 generation backK063548 Cor Analyzer 1, Version 1.4Rcadia Medical Imaging, Ltd. · 2007
  6. This deviceK072242 Cor Analyzer II, Model V1.7Rcadia Medical Imaging, Ltd. · 2007
  7. Descendant · cites it directly · 4 of its ownK110071 Cor AnalyzerRcadia Medical Imaging, Ltd. · 2011
  8. Descendant · 2 generations on · 3 of its ownK123646 Emory Cardiac Toolbox 4.0Syntermed, Inc. · 2013
  9. Descendant · 3 generations on · 1 of its ownK231731 Optional Screen Displays for HeartSee Cardiac P.E.T. Processing…Mcgovern Medical School · 2023
  10. Descendant · 4 generations on · 0 of its ownK243881 HeartSee™ Cardiac P.E.T. Processing Software For Myocardial…Bracco Diagnostics, Inc. · 2025
  11. Descendant · 3 generations on · 0 of its ownK223422 Emory Cardiac Toolbox 4.3Syntermed · 2023
Show all 10 generations
  1. Root · 10 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 9 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 8 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 7 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 6 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 5 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 4 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 3 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 2 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 1 generation backK063548 Cor Analyzer 1, Version 1.4Rcadia Medical Imaging, Ltd. · 2007
  11. This deviceK072242 Cor Analyzer II, Model V1.7Rcadia Medical Imaging, Ltd. · 2007

Most influential descendants

Showing 5 of 5 · See all
  • K110071Cor AnalyzerRcadia Medical Imaging, Ltd. · 2011 · cites it directly4descendants
  • K123646Emory Cardiac Toolbox 4.0Syntermed, Inc. · 2013 · 2 generations on3descendants
  • K231731Optional Screen Displays for HeartSee Cardiac P.E.T. Processing Software - HeartSee…Mcgovern Medical School · 2023 · 3 generations on1descendant
  • K243881HeartSee™ Cardiac P.E.T. Processing Software For Myocardial Perfusion and Coronary Flow…Bracco Diagnostics, Inc. · 2025 · 4 generations on0descendants
  • K223422Emory Cardiac Toolbox 4.3Syntermed · 2023 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−9K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−8K020483Advantage Workstation 4.1GE Medical Systems20022
−7K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−6K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−5K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−4K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−3K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−2K061624Vitrea, Version 3.9Vital Images, Inc.20061
−1K063548Cor Analyzer 1, Version 1.4Rcadia Medical Imaging, Ltd.2007—
0 (this device)K072242Cor Analyzer II, Model V1.7Rcadia Medical Imaging, Ltd.2007—
+1K110071Cor AnalyzerRcadia Medical Imaging, Ltd.2011—
+2K123646Emory Cardiac Toolbox 4.0Syntermed, Inc.2013—
+3K231731Optional Screen Displays for HeartSee Cardiac P.E.T. Processing Software -…Mcgovern Medical School2023—
+4K243881HeartSee™ Cardiac P.E.T. Processing Software For Myocardial Perfusion and…Bracco Diagnostics, Inc.2025—
+3K223422Emory Cardiac Toolbox 4.3Syntermed2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199630
199720
199820
199920
200020
200140
200220
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201310
202320
202510
FIG. 1 — Lineage of K072242, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061624Vitrea, Version 3.9
Summary page 1
…cations system Regulatory class: Class II Reason for 510(k) Submission Special 5 10(k) Submission Identification of Legally Marketed Equivalent Devices K06 1624 Vitrea2, K063548 COR Analyzer I Device Description COR Analyzer I is a post processing software application which runs on a stan…
Vital Images, Inc.20061
*K063548Cor Analyzer 1, Version 1.4
Summary page 1
…ulatory class: Class II Reason for 510(k) Submission Special 5 10(k) Submission Identification of Legally Marketed Equivalent Devices K06 1624 Vitrea2, K063548 COR Analyzer I Device Description COR Analyzer I is a post processing software application which runs on a stand-alone Windows b…
Rcadia Medical Imaging, Ltd.2007—

Also cleared against K061624: 8 other devices →

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110071Cor AnalyzerRcadia Medical Imaging, Ltd.20114

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 10 months on median.
  • 7 of the 31 ancestors have a recall of any class.
  • Of its descendants, K110071 (Rcadia Medical Imaging, Ltd., 2011) has gone furthest, with 4 descendants of its own.
  • 8 other devices also cite its predicate K061624.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

The COR Analyzer II is intended to assist a trained physician to analyze Computed Tomography (CT) Angiographic images. The device is not intended for use with mammography. The COR Analyzer II is specifically indicated to provide visualization of the major coronary vessels and lesions, thus assisting the physician in visualizing the coronary anatomy and pathology. COR Analyzer II has abilities for coronary vessels segmentations, abnormalities display and processing.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072242: Cor Analyzer II, Model V1.7.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K072242

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026