ClearedPhilips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment Tool
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Philips Medical Systems (Cleveland), Inc. · JAK System, X-Ray, Tomography, Computed
Cleared on Oct 9, 2009 as substantially equivalent to K042293 (Philips Medical Systems (Cleveland), Inc., 2004) and 5 other predicates after a 31-day review. Its family tree reaches back 9 generations to 1991. 19 later devices descend from it.
- Decided
- Oct 9, 2009
- Review
- 31 days
- Class
- Class II
- Product code
- JAK
- Recalls
- None
- Predicates
- 6
Its longest line of descent runs back 9 generations to K913770 (1991). 63 ancestors in all, the oldest K871859 (1987). 19 later devices descend from it, 2 citing it directly.
- Root · 9 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
- 5 generations between
- 3 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
- 2 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
- 1 generation backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
- This deviceK092747 Philips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment ToolPhilips Medical Systems (Cleveland), Inc. · 2009
- Descendant · cites it directly · 16 of its ownK122429 Vessel Analysis and Autoplaque for Ors VisualObject Research Systems (Ors), Inc. · 2012
- Descendant · 2 generations on · 7 of its ownK190868 Cleerly LabsCleerly, Inc. · 2019
- Descendant · 3 generations on · 5 of its ownK202280 Cleerly Labs v2.0Cleerly, Inc. · 2020
- Descendant · 2 generations on · 3 of its ownK212758 AutoplaqueCedars-Sinai Medical Center: Aim · 2023
- Descendant · 4 generations on · 2 of its ownK242338 Cleerly LABS (v2.0)Cleerly, Inc. · 2025
Show all 9 generations
- Root · 9 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
- 8 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
- 7 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
- 6 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
- 5 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
- 4 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
- 3 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
- 2 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
- 1 generation backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
- This deviceK092747 Philips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment ToolPhilips Medical Systems (Cleveland), Inc. · 2009
Showing 5 of 19 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 19 · See all- K122429Vessel Analysis and Autoplaque for Ors VisualObject Research Systems (Ors), Inc. · 2012 · cites it directly16descendants
- K190868Cleerly LabsCleerly, Inc. · 2019 · 2 generations on7descendants
- K202280Cleerly Labs v2.0Cleerly, Inc. · 2020 · 3 generations on5descendants
- K212758AutoplaqueCedars-Sinai Medical Center: Aim · 2023 · 2 generations on3descendants
- K242338Cleerly LABS (v2.0)Cleerly, Inc. · 2025 · 4 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K913770 | Advantage V.S. CT/MR Rad Diagnostic Workstation | General Electric Co. | 1991 | — |
| −8 | K960613 | GE Advantage Windows Review Workstation | GE Medical Systems | 1996 | — |
| −7 | K020483 | Advantage Workstation 4.1 | GE Medical Systems | 2002 | 2 |
| −6 | K023003 | Imagechecker-CT Workstation | R2 Technology, Inc. | 2002 | — |
| −5 | K032748 | VITREA2, Version 3.4 Medical Image Processing Software | Vital Images, Inc. | 2003 | 2 |
| −4 | K040305 | VITREA2 Version 3.5 | Vital Images, Inc. | 2004 | — |
| −3 | K043333 | VITREA2, Version 3.7 Medical Image Processing System | Vital Images, Inc. | 2004 | 1 |
| −2 | K052632 | VITREA2 Version 3.8 Medical Image Processing Software | Vital Images, Inc. | 2005 | 2 |
| −1 | K061624 | Vitrea, Version 3.9 | Vital Images, Inc. | 2006 | 1 |
| 0 (this device) | K092747 | Philips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment Tool | Philips Medical Systems (Cleveland), Inc. | 2009 | — |
| +1 | K122429 | Vessel Analysis and Autoplaque for Ors Visual | Object Research Systems (Ors), Inc. | 2012 | — |
| +2 | K190868 | Cleerly Labs | Cleerly, Inc. | 2019 | — |
| +3 | K202280 | Cleerly Labs v2.0 | Cleerly, Inc. | 2020 | — |
| +2 | K212758 | Autoplaque | Cedars-Sinai Medical Center: Aim | 2023 | — |
| +4 | K242338 | Cleerly LABS (v2.0) | Cleerly, Inc. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1993 | 3 | 0 |
| 1994 | 4 | 0 |
| 1995 | 3 | 0 |
| 1996 | 5 | 0 |
| 1997 | 4 | 0 |
| 1998 | 4 | 0 |
| 1999 | 4 | 0 |
| 2000 | 3 | 0 |
| 2001 | 7 | 0 |
| 2002 | 5 | 0 |
| 2003 | 2 | 0 |
| 2004 | 4 | 0 |
| 2005 | 1 | 0 |
| 2006 | 2 | 0 |
| 2007 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 1 | 0 |
| 2019 | 1 | 0 |
| 2020 | 1 | 0 |
| 2022 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 2 | 0 |
| 2025 | 7 | 0 |
| 2026 | 5 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (6)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K042293 | Brilliance CT, Private Practice CV Configuration, CT ScannerSummary page 1…ly in commercial distribution, namely: * Philips Medical Systemrs (Cleveland), Inc., Brilliance CT, Private Practice CV Configuration, K042293 * Shina Systems Ltd., CardioCT, K070226 * GE- CardlQ Fusion, K06 1370 * GE - Advanced Vess… | 2004 |
| * | K070226 | CardioctSummary page 1…* Philips Medical Systemrs (Cleveland), Inc., Brilliance CT, Private Practice CV Configuration, K042293 * Shina Systems Ltd., CardioCT, K070226 * GE- CardlQ Fusion, K06 1370 * GE - Advanced Vessel Analysis LI, K060779 * Vital Imaging… | 2007 |
| * | K061370 | Cardiq FusionSummary page 1…, Inc., Brilliance CT, Private Practice CV Configuration, K042293 * Shina Systems Ltd., CardioCT, K070226 * GE- CardlQ Fusion, K06 1370 * GE - Advanced Vessel Analysis LI, K060779 * Vital Imaging - Vitrea2 Ver. 3.9, K06 1624 (specifically… | 2006 |
| * | K060779 | Advance Vessel Analysis IISummary page 1…V Configuration, K042293 * Shina Systems Ltd., CardioCT, K070226 * GE- CardlQ Fusion, K06 1370 * GE - Advanced Vessel Analysis LI, K060779 * Vital Imaging - Vitrea2 Ver. 3.9, K06 1624 (specifically the SUREPlaque tools) * Sie… | 2006 |
| * | K061624 | Vitrea, Version 3.9Summary page 1…., CardioCT, K070226 * GE- CardlQ Fusion, K06 1370 * GE - Advanced Vessel Analysis LI, K060779 * Vital Imaging - Vitrea2 Ver. 3.9, K06 1624 (specifically the SUREPlaque tools) * Siemens - syngo Circulation, K063 762 Comprehensive Cardia… | 2006 |
| * | K063762 | Syngo Circulation Software Package with Extended FunctionalitySummary page 1…is LI, K060779 * Vital Imaging - Vitrea2 Ver. 3.9, K06 1624 (specifically the SUREPlaque tools) * Siemens - syngo Circulation, K063 762 Comprehensive Cardiac Analysis (CCA) - Plaque Assessment tool Page III - 1 4. Device D… | 2007 |
What descends from it? (19)
See all 192 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 11 months on median.
- 14 of the 63 ancestors have a recall of any class.
- Of its descendants, K122429 (Object Research Systems (Ors), Inc., 2012) has gone furthest, with 16 descendants of its own.
- 5 other devices also cite its predicate K042293.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
The Plaque Analysis option is a non-invasive diagnostic reading software intended for use by cardiologists and radiologists as an interactive tool for viewing and analyzing cardiac CT data for determining the presence and extent of coronary plaques.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K092747 · printed Nov 4, 2026
Cite this page
510(k) Report. “K092747: Philips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment Tool.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K092747
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026