510(k) Report

510(k) · Cleared

Cleared

Model 250CX Series Maternal/Fetal Monitor

K072976510(k) SpecialCleared Dec 20, 200756-day reviewClass II21 CFR 884.2740

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Healthcare · HGM System, Monitoring, Perinatal

Cleared on Dec 20, 2007 as substantially equivalent to K050583 (Ge Medical Systems Information Technologies, 2005) after a 56-day review. Its family tree reaches back 7 generations to 1997. 2 of the 37 devices in its family, counting itself, have a Class I recall.

Decided
Dec 20, 2007
Review
56 days
Class
Class II
Product code
HGM
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K962603 (1997). 36 ancestors in all, the oldest K852608 (1985). No later device cites it as a predicate yet. 2 of the 37 devices in this family, counting this one, have a Class I recall.

  1. Root · 7 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 6 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 5 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 4 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 3 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 2 generations backK021089 Oximax Max-Fast Adhesive Forehead SensorNellcor Puritan Bennett, Inc. · 2002
  7. 1 generation backK050583 Model 250 Series Maternal/Fetal MonitorGe Medical Systems Information Technologies · 2005
  8. This deviceK072976 Model 250CX Series Maternal/Fetal MonitorGE Healthcare · 2007

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−6K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−5K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−4K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−3K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−2K021089Oximax Max-Fast Adhesive Forehead SensorNellcor Puritan Bennett, Inc.2002—
−1K050583Model 250 Series Maternal/Fetal MonitorGe Medical Systems Information Technologies2005—
0 (this device)K072976Model 250CX Series Maternal/Fetal MonitorGE Healthcare2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198610
199020
199110
199410
199510
199630
199710
199810
199940
200030
200120
200221
200350
200411
FIG. 1 — Lineage of K072976, 1997–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HGM device

  1. #1 K241882 Fetal & Maternal Monitor (F15A, F15A Air)score 19.5 · 33 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K050583Model 250 Series Maternal/Fetal Monitor
Summary page 1
…atal Predicate Device Information rdicote Devic 1~~Nme MODEL 250 SERIES MATERNAL/FETAL MONITOR K050583 Intended Use Statement I. Fetal Surveillance A Corometrics 250 Series Maternal/Fetal Monitoring System is used for non- invasi…
Ge Medical Systems Information Technologies2005—
†K011291Temporalscanner Thermometer, SensortouchExergen Corp.2001—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K040831Datex-Ohmeda Trusat Pulse Oximeter and Accessories, Model 3500Datex-Ohmeda, Inc. · 2004 · 2 generations back · ◆ in the 2004 ancestors bar of FIG. 13 Class I recalls
  • K021955Trutrak Plus Enhancements to the Datex-Ohmeda 3800 Series & 3900 Series Oximeters & AccessoriesDatex-Ohmeda, Inc. · 2002 · 3 generations back · ◆ in the 2002 ancestors bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 10 years and passes through 5 companies; a new generation was cleared every 11 months on median.
  • 10 of the 36 ancestors have a recall of any class; 2 have a Class I recall.

How does its category compare?

All HGM devices

HGM System, Monitoring, Perinatal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · HGM

4in 2025

2007: 32008: 42009: 42010: 42011: 132012: 42013: 22014: 42015: 52016: 12017: 32018: 32020: 12022: 12023: 22024: 12025: 42026 (partial year): 2
2007high 13 (2011) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HGM

269in 2025

2007: 56 days median2008: 75 days median2009: 66 days median2010: 193 days median2011: 141 days median2012: 107 days median2014: 231 days median2015: 169 days median2017: 138 days median2018: 258 days median2025: 269 days median
2007high 269 (2025) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HGM

5in 2019

2008: 42009: 62013: 12014: 12019: 52026 (partial year): 2
2007high 6 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HGM

99in 2025

2007: 352008: 172009: 422010: 642011: 832012: 442013: 162014: 302015: 442016: 172017: 272018: 302019: 412020: 192021: 712022: 872023: 692024: 1742025: 99
2007high 174 (2024) · low 16 (2013)2025

MAUDE reports naming product code HGM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007356035
2008475417
2009466642
20104193064
201113141083
20124107044
20132—116
20144231130
20155169044
20161—017
20173138027
20183258030
20190—541
20201—019
20210—071
20221—087
20232—069
20241—0174
20254269099
20262—2—

What is it indicated for?

I. Fetal Surveillance A Corometrics 250 Series Maternal/Fetal Monitoring System is used for non-invasive and invasive monitoring of the fetus during the antepartum period as well as throughout labor and delivery (i.e. fetal heart rate and uterine activity monitoring). Fetal movement detection and fetal heart rate alarm options (user selectable high/low and poor signal quality alarms) are available. II.Maternal Monitoring A Corometrics 250 Series…

Read the full statement (213 words)

I. Fetal Surveillance

A Corometrics 250 Series Maternal/Fetal Monitoring System is used for non-invasive and invasive monitoring of the fetus during the antepartum period as well as throughout labor and delivery (i.e. fetal heart rate and uterine activity monitoring). Fetal movement detection and fetal heart rate alarm options (user selectable high/low and poor signal quality alarms) are available.

II.Maternal Monitoring

A Corometrics 250 Series Maternal/Fetal Monitoring System is intended for monitoring maternal vital signs to help assess maternal well-being. The vital signs which can be measured with these monitor configurations are summarized as follows:

NOTE: Maternal vital signs provided by the monitor should only be used as an adjunct in patient assessment in conjunction with clinical signs and symptoms.

Blood Pressure: The monitor is intended for use in the non-invasive monitoring of maternal blood pressure (NBP). This monitor is not intended for use in the neonatal or pediatric blood pressure monitoring.

Pulse Oximetry. The monitor is intended for use in the non-invasive monitoring of maternal functional oxygen saturation of arterial hemoglobin (MSpO2).

Heart/Pulse Rate. The monitor is intended for use in the non-invasive monitoring of the maternal heart/pulse rate. Additionally, an MECG waveform 'snapshot" may be displayed and printed.

NOTE: Only the maximum configuration provides both maternal heart rate and pulse rate data.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072976: Model 250CX Series Maternal/Fetal Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K072976

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026