Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories)

K012891510(k) TraditionalCleared Mar 7, 2002191-day reviewClass II21 CFR 870.2700Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nellcor Puritan Bennett, Inc. · DQA Oximeter

Cleared on Mar 7, 2002 as substantially equivalent to K991823 (Nellcor Puritan Bennett, Inc., 1999) and 3 other predicates after a 191-day review. Its family tree reaches back 4 generations to 1997. 2 of the 557 devices in its family, counting itself, have a Class I recall. 548 later devices descend from it. It has been recalled once.

Decided
Mar 7, 2002
Review
191 days
Class
Class II
Product code
DQA
Recalls
1
Predicates
4

Its longest line of descent runs back 4 generations to K962603 (1997). 8 ancestors in all, the oldest K904039 (1990). 548 later devices descend from it, 34 citing it directly. 2 of the 557 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1999: 1 other ancestor1995: 1 other ancestor1990: 1 other ancestor1996: 1 other ancestor2002: 6 descendants cleared2007: 8 descendants cleared2022: 38 descendants cleared2005: 12 descendants cleared2009: 21 descendants cleared2004: 9 descendants cleared2003: 4 descendants cleared2006: 7 descendants cleared2013: 28 descendants cleared2014: 27 descendants cleared, 2 with a Class I recall22008: 12 descendants cleared2017: 27 descendants cleared2015: 35 descendants cleared2010: 22 descendants cleared2012: 27 descendants cleared2011: 20 descendants cleared2019: 27 descendants cleared2016: 25 descendants cleared2018: 31 descendants cleared2021: 22 descendants cleared2020: 22 descendants cleared2026: 24 descendants cleared2025: 31 descendants cleared2023: 33 descendants cleared2024: 30 descendants clearedK962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 19991990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 1 other ancestor 1 generation forward: 34 descendants2 generations forward: 49 descendants3 generations forward: 65 descendants4 generations forward: 86 descendants5 generations forward: 88 descendants, 1 with a Class I recall16 generations forward: 73 descendants7 generations forward: 60 descendants, 1 with a Class I recall18 generations forward: 47 descendants9 generations forward: 36 descendants10 generations forward: 9 descendants11 generations forward: 1 descendant K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 19970+5+10
  1. Root · 4 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 3 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 2 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 1 generation backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. This deviceK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002
  6. Descendant · cites it directly · 426 of its ownK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
  7. Descendant · 2 generations on · 290 of its ownK031740 VSM - Vital Signs Monitor, Model 53000 SeriesWelch Allyn Protocol, Inc. · 2003
  8. Descendant · cites it directly · 272 of its ownK033048 Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS…Cas Medical Systems, Inc. · 2004 · Recalled
  9. Descendant · cites it directly · 264 of its ownK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  10. Descendant · cites it directly · 250 of its ownK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled

Showing 5 of 548 descendants. See all descendants

Descendants cleared per year

2002: 62003: 42004: 92005: 122006: 72007: 82008: 122009: 212010: 222011: 202012: 272013: 282014: 272015: 352016: 252017: 272018: 312019: 272020: 222021: 222022: 382023: 332024: 302025: 312026: 24
2002high 38 (2022) · low 4 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 548 · See all
  • K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002 · cites it directly426descendants
  • K031740VSM - Vital Signs Monitor, Model 53000 SeriesWelch Allyn Protocol, Inc. · 2003 · 2 generations on290descendants
  • K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL…Cas Medical Systems, Inc. · 2004 · cites it directly272descendants
  • K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS…Cas Medical Systems, Inc. · 2005 · cites it directly264descendants
  • K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside MonitorOridion Capnography, Inc. · 2006 · cites it directly250descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−3K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−2K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−1K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
0 (this device)K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.2002—
+1K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002—
+2K031740VSM - Vital Signs Monitor, Model 53000 SeriesWelch Allyn Protocol, Inc.2003—
+1K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL…Cas Medical Systems, Inc.20041
+1K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL…Cas Medical Systems, Inc.2005—
+1K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter…Oridion Capnography, Inc.20063

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199510
199610
199910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200260
200340
200490
2005120
200670
200780
2008120
2009210
2010220
2011200
2012270
2013280
2014272
2015350
2016250
2017270
2018310
2019270
2020220
2021220
2022380
2023330
2024300
2025310
2026240
FIG. 1 — Lineage of K012891, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQA device

  1. #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K991823N-395 Pulse Oximeter, Model N-395
Summary page 1
…CFR §870.2700) Patient Transducer and Electrode Cable (including connector) (74DSA) (per 21 CFR §870.2900) 1. Nellcor Puritan Bennett Inc. N-395 Pulse Oximeter, 510(k) #K991823 2. Nellcor Puritan Bennett Inc. N-395 Pulse Oximeter, With Extended Device Claims, 510(k) #K993637 3. Nellcor Inc. Reflectance…
Nellcor Puritan Bennett, Inc.1999—
*K993637N-395 Pulse Oximeter, with Extended Device Claims
Summary page 1
….2900) 1. Nellcor Puritan Bennett Inc. N-395 Pulse Oximeter, 510(k) #K991823 2. Nellcor Puritan Bennett Inc. N-395 Pulse Oximeter, With Extended Device Claims, 510(k) #K993637 3. Nellcor Inc. Reflectance Sensor (RS-10), 510(k) #K904039 4. Nellcor N-20PA Portable Pulse Oximeter, 510(k) #K952222 The Oxi…
Nellcor Puritan Bennett, Inc.19991
*K904039Reflectance Sensor (RS-10)
Summary page 1
…510(k) #K991823 2. Nellcor Puritan Bennett Inc. N-395 Pulse Oximeter, With Extended Device Claims, 510(k) #K993637 3. Nellcor Inc. Reflectance Sensor (RS-10), 510(k) #K904039 4. Nellcor N-20PA Portable Pulse Oximeter, 510(k) #K952222 The OxiMAX Pulse Oximetry System is designed for continuous, non-inv…
Nellcor, Inc.19901
*K952222Nellcor N-20PA Portable Pulse Oximeter
Summary page 1
…e Oximeter, With Extended Device Claims, 510(k) #K993637 3. Nellcor Inc. Reflectance Sensor (RS-10), 510(k) #K904039 4. Nellcor N-20PA Portable Pulse Oximeter, 510(k) #K952222 The OxiMAX Pulse Oximetry System is designed for continuous, non-invasive monitoring of functional oxygen saturation of arterial…
Nellcor, Inc.1995—

Also cleared against K991823: 20 other devices →

What descends from it? (548)

See all 548

34 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002426
K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL…Cas Medical Systems, Inc.2004272
K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS…Cas Medical Systems, Inc.2005264
K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside MonitorOridion Capnography, Inc.2006250
K060576Nellcor Oximax N-600X Pulse OximeterNellcor Puritan Bennett, Inc.2006140
K073036Fore-Sight, MC-2000 SeriesCas Medical Systems, Inc.200859
K083892Fore-Sight, Model MC-2000 Series (MC-2000, MC-2010, MC2020, MC2030)Cas Medical Systems, Inc.200958
K130320Bedside Respiratory Patient Monitoring System, Bedside Respiratory Patient Monitoring…Covidien201440
K123581Nellcor Oximax N-600X Pulse Oximeter, Nellcor Bedside Respiratory Patient Monitoring…Covidien, Formerly Nellcor Puritan Bennett, Inc.201334
K022193Dinamap Procare Series Monitor, Models 100N, 200N, 300N, 400NGe Medical Systems Information Technologies200221

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 18, 2004Not classifiedZ-0664-05OtherThe internal speaker components are failing and do not produce an audio alarm in the event of patient emergency.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K133576Monitor B40Ge Medical Systems China Co., Ltd. · 2014 · 5 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall
  • K123690CAPNOSTREAM20P with Hifi C02 MonitoringOridion Medical 1987, Ltd. · 2014 · 7 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 11 months on median.
  • 2 of the 8 ancestors have a recall of any class.
  • Of its descendants, K021090 (Nellcor Puritan Bennett, Inc., 2002) has gone furthest, with 426 descendants of its own.
  • 20 other devices also cite its predicate K991823.

How does its category compare?

All DQA devices

DQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DQA

15in 2025

2007: 202008: 222009: 352010: 292011: 152012: 142013: 152014: 112015: 132016: 142017: 92018: 182019: 192020: 152021: 102022: 202023: 132024: 142025: 152026 (partial year): 8
2007high 35 (2009) · low 9 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQA

182in 2025

2007: 122 days median2008: 97 days median2009: 117 days median2010: 127 days median2011: 195 days median2012: 120 days median2013: 182 days median2014: 175 days median2015: 158 days median2016: 246 days median2017: 200 days median2018: 260 days median2019: 158 days median2020: 126 days median2021: 174 days median2022: 265 days median2023: 317 days median2024: 285 days median2025: 182 days median2026 (partial year): 187 days median
2007high 317 (2023) · low 97 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQA

3in 2024

2007: 62008: 52009: 292010: 42011: 12014: 22015: 12018: 322024: 3
2007high 32 (2018) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQA

399in 2025

2007: 3252008: 3122009: 2812010: 1852011: 1642012: 3222013: 4682014: 1,1242015: 2,0822016: 1,7752017: 1,1902018: 6942019: 5482020: 4262021: 5532022: 4782023: 3922024: 5452025: 399
2007high 2,082 (2015) · low 164 (2011)2025

MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007201226325
200822975312
20093511729281
2010291274185
2011151951164
2012141200322
2013151820468
20141117521,124
20151315812,082
20161424601,775
2017920001,190
20181826032694
2019191580548
2020151260426
2021101740553
2022202650478
2023133170392
2024142853545
2025151820399
202681870—

What is it indicated for?

The OxiMAX Pulse Oximetry System with N-595 Pulse Oximeter and OxiMAX Sensors and Cables is indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate. The OxiMAX Pulse Oximetry System is intended for use with neonatal, pediatric, and adult patients during both no motion and motion conditions and for patients who are either well or poorly perfused, in hospitals, hospital-type…

Read the full statement (772 words)

The OxiMAX Pulse Oximetry System with N-595 Pulse Oximeter and OxiMAX Sensors and Cables is indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate. The OxiMAX Pulse Oximetry System is intended for use with neonatal, pediatric, and adult patients during both no motion and motion conditions and for patients who are either well or poorly perfused, in hospitals, hospital-type facilities, intra-hospital transport, and home environments. These devices are for prescription use only.

The Nellcor OxiMAX adult oxygen sensor, model MAX-A, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing more than 30 kg.

The Nellcor OxiMAX adult oxygen sensor, model MAX-AL, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing more than 30 kg.

The Nellcor OxiMAX pediatric oxygen sensor, model MAX-P, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 10 and 50 kg.

The Nellcor OxiMAX infant oxygen sensor, model MAX-I, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 3 and 20 kg.

The Nellcor OxiMAX neonatal/adult oxygen sensor, model MAX-N, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for neonates weighing less than 3 kg or adults weighing more than 40 kg.

The Nellcor OxiMAX adult nasal oxygen sensor, model MAX-R, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing more than 50 kg.

The Nellcor OxiMAX adhesive forehead reflectance sensor, model MAX-FAST, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing greater than 40 kg.

The Nellcor OxiMAX OxiCliq adult oxygen sensor, model A, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing more than 30 kg. The OxiClig-A sensor is for use only with a Nellcor OxiCliq sensor cable, model OC-3.

The Nellcor OxiMAX OxiCliq pediatric oxygen sensor, model P, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 10 and 50 kg. The OxiCliq-P sensor is for use only with a Nellcor OxiCliq sensor cable, model OC-3.

The Nellcor OxiMAX OxiCliq infant oxygen sensor, model I, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 3 and 20 kg. The OxiClig-I sensor is for use only with a Nellcor OxiCliq sensor cable, model OC-3.

The Nellcor OxiMAX OxiCliq neonatal/adult oxygen sensor, model N, is indicated for single-patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for neonates weighing less than 3 kg, or adults weighing more than 40 kg. The OxiClig-N sensor is for use only with a Nellcor OxiCliq sensor cable, model OC-3.

The Nellcor OxiMAX Durasensor adult oxygen sensor, model DS-100A, is indicated for use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing greater than 40 kg.

The Nellcor OxiMAX Dura-Y multisite oxygen sensor, model D-YS, is indicated for use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing greater than 1 kg.

The Nellcor Dura-Y ear clip, model D-YSE, is intended for use only with the Nellcor OxiMAX Dura-Y oxygen sensor, model D-YS, when continuous, noninvasive arterial oxygen saturation and pulse rate monitoring are required. It is indicated for use for patients weighing 30 kg or more, using the ear lobe or pinna as a monitoring site.

The Nellcor PediCheck pediatric spot-check clip, model D-YSPD, is intended for use only with the Nellcor OxiMAX Dura-Y oxygen sensor, model D-YS, when noninvasive, arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 3 kg and 40 kg.

The Nellcor OxiMAX Oxiband pediatric/infant oxygen sensor, model OXI-P/I, is indicated for use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing between 3 kg and 40 kg.

The Nellcor OxiMAX Oxiband adult/neonatal oxygen sensor, model OXI-A/N, is indicated for use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing less than 3 kg or more than 40 kg.

The Nellcor pulse oximetry cable, model DOC-10, is a 10-foot (3-meter) cable that links a Nellcor oxygen sensor to a compatible Nellcor pulse oximeter.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K012891: Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K012891

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026