510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Medrad Continuum MR Infusion System with Wireless Remote Accessory

K073051510(k) AbbreviatedCleared May 30, 2008214-day reviewClass II21 CFR 880.5725Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medrad, Inc. · FRN Pump, Infusion

Cleared on May 30, 2008 as substantially equivalent to K061128 (Medrad, Inc., 2006) and 1 other predicate after a 214-day review. Its family tree reaches back 3 generations to 2000. 1 of the 8 devices in its family, counting itself, has a Class I recall. It has been recalled 2 times.

Decided
May 30, 2008
Review
214 days
Class
Class II
Product code
FRN
Recalls
2
Predicates
2

Its longest line of descent runs back 3 generations to K002211 (2000). 7 ancestors in all. No later device cites it as a predicate yet. 1 of the 8 devices in this family, counting this one, has a Class I recall.

  1. Root · 3 generations backK002211 Colleague CX Volumetric Infusion Pump 2M8161 and Volumeteric…Baxter Healthcare Corp · 2000 · Recalled
  2. 2 generations backK012383 Gemini PC-1,PC-2, PC-2TX,PC-4, Signature Edition Infusion Pump (SE)…Alaris Medical Systems, Inc. · 2001 · Recalled (Class I)
  3. 1 generation backK050301 Mridium 3850 Mri Pump SystemIradimed Corporation · 2005 · Recalled
  4. This deviceK073051 Medrad Continuum MR Infusion System with Wireless Remote AccessoryMedrad, Inc. · 2008

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K002211Colleague CX Volumetric Infusion Pump 2M8161 and Volumeteric Infusion Pump…Baxter Healthcare Corp20004
−2K012383Gemini PC-1,PC-2, PC-2TX,PC-4, Signature Edition Infusion Pump (SE), Medsystem…Alaris Medical Systems, Inc.2001Class I
−1K050301Mridium 3850 Mri Pump SystemIradimed Corporation20052
0 (this device)K073051Medrad Continuum MR Infusion System with Wireless Remote AccessoryMedrad, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200210
200310
200610
FIG. 1 — Lineage of K073051, 2000–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061128Modification to Medrad Continuum MR Infusion System
Summary page 1
…sion Pump - Class 11(see 21 CFR 880.5725) COMMON NAME: Peristaltic Pump PRODUCT CODE: FRN PREDICATE DEVICES: K061128, MEDRAD Continuum MR Compatible Infusion System (3T Proximity)…
Medrad, Inc.2006—
*K050301Mridium 3850 Mri Pump System
Summary page 1
…ATE DEVICES: K061128, MEDRAD Continuum MR Compatible Infusion System (3T Proximity) K050301, Iradimed MRidium 3850 MRI Infusion Pump System INDICATIONS FOR USE: The MEDRAD Continuum MR Infusion System with…
Iradimed Corporation20052

Also cleared against K061128: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 3, 2014Class IIZ-1673-2014Component design/selectionThere is a potential safety risk associated with potentially damaged locking pins within the bracket of non-wireless versions of Continuum systems shipped prior to March 2008.
Apr 18, 2012Class IIZ-0595-2013Nonconforming Material/ComponentBayer HealthCare is recalling all MEDRAD(R) Continuum MF Infusion System tubing sets (macrobore and microbore), catalog numbers MIK200A, MIL 200B, 3015153, 3015155, 3015156, 3015157, 3015158, 3015159, and 3015161. The firm is initiating…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K012383Gemini PC-1,PC-2, PC-2TX,PC-4, Signature Edition Infusion Pump (SE), Medsystem Iii Infusion (Msiii)…Alaris Medical Systems, Inc. · 2001 · 2 generations back · ◆ on the line of descent in FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 8 years and passes through 4 companies; a new generation was cleared every 3.2 years on median.
  • 6 of the 7 ancestors have a recall of any class; 1 has a Class I recall.
  • 1 other device also cites its predicate K061128.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The MEDRAD Continuum MR Infusion System with Wireless Remote Accessory is designed for patients who require medications and other fluids during an MR procedure. It is intended to provide infusion therapy directly prior to, during and immediately after the MR procedure functioning while either stationary or mobile. It is not intended to provide long-term patient care outside the MR environment. The system is to be used by trained medical staff, primarily critical care, emergency room and radiology nursing staff.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K073051: Medrad Continuum MR Infusion System with Wireless Remote Accessory.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K073051

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026