510(k) Report

510(k) · Cleared

Cleared

Finger Pulse Oximeter, Model 9560

K081285510(k) SpecialCleared Jun 5, 200830-day reviewClass II21 CFR 870.2700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nonin Medical, Inc. · DQA Oximeter

Cleared on Jun 5, 2008 as substantially equivalent to K053130 (Nonin Medical, Inc., 2006) and 1 other predicate after a 30-day review. Its family tree reaches back 7 generations to 1991. 40 later devices descend from it.

Decided
Jun 5, 2008
Review
30 days
Class
Class II
Product code
DQA
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K910772 (1991). 17 ancestors in all, the oldest K893221 (1990). 40 later devices descend from it, 4 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor2005: 1 other ancestor2000: 2 other ancestors1997: 2 other ancestors1995: 1 other ancestor1993: 1 other ancestor1990: 1 other ancestor1992: 1 other ancestor2013: 1 descendant cleared2009: 1 descendant cleared2015: 2 descendants cleared2012: 2 descendants cleared2014: 1 descendant cleared2019: 3 descendants cleared2016: 1 descendant cleared2018: 1 descendant cleared2022: 7 descendants cleared2024: 7 descendants cleared2025: 7 descendants cleared2021: 1 descendant cleared2023: 3 descendants cleared2026: 3 descendants clearedK910772 · Propaq 102, 104 and 106 · Protocol Systems, Inc. · 1991×3: 3 generations cleared close together, K972020 (1998), K980879 (1998), K982776 (1998) K013319 · Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure (Nibp) Monitor · Nonin Medical, Inc. · 2002K041156 · Avant Digital Pulse Oximetry System, Models 4000, 4001 · Nonin Medical, Inc. · 2004 · recalledK043359 · 4100 Patient Oximeter Module · Nonin Medical, Inc. · 20051990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 1 other ancestor4 generations back: 2 other ancestors5 generations back: 4 other ancestors7 generations back: 1 other ancestor 1 generation forward: 4 descendants2 generations forward: 5 descendants3 generations forward: 9 descendants4 generations forward: 12 descendants5 generations forward: 9 descendants6 generations forward: 1 descendant K043359 · 4100 Patient Oximeter Module · Nonin Medical, Inc. · 2005K041156 · Avant Digital Pulse Oximetry System, Models 4000, 4001 · Nonin Medical, Inc. · 2004 · recalledK013319 · Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure (Nibp) Monitor · Nonin Medical, Inc. · 2002K982776 · 9303 Neonatal/Adult Vital Signs Monitor · Cas Medical Systems, Inc. · 1998K980879 · Oscillomate Nibp / SP02 Ems Monitor · Cas Medical Systems, Inc. · 1998K972020 · Oscillomate Non-Invasive Blood Pressure Monitor · Cas Medical Systems, Inc. · 1998K910772 · Propaq 102, 104 and 106 · Protocol Systems, Inc. · 1991−50+5
  1. Root · 7 generations backK910772 Propaq 102, 104 and 106Protocol Systems, Inc. · 1991
  2. 6 generations backK972020 Oscillomate Non-Invasive Blood Pressure MonitorCas Medical Systems, Inc. · 1998
  3. 5 generations backK980879 Oscillomate Nibp / SP02 Ems MonitorCas Medical Systems, Inc. · 1998
  4. 4 generations backK982776 9303 Neonatal/Adult Vital Signs MonitorCas Medical Systems, Inc. · 1998
  5. 3 generations backK013319 Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure…Nonin Medical, Inc. · 2002
  6. 2 generations backK041156 Avant Digital Pulse Oximetry System, Models 4000, 4001Nonin Medical, Inc. · 2004 · Recalled
  7. 1 generation backK043359 4100 Patient Oximeter ModuleNonin Medical, Inc. · 2005
  8. This deviceK081285 Finger Pulse Oximeter, Model 9560Nonin Medical, Inc. · 2008
  9. Descendant · cites it directly · 24 of its ownK150314 Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015
  10. Descendant · 2 generations on · 23 of its ownK181956 Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2019
  11. Descendant · 3 generations on · 10 of its ownK181352 Loop SystemSpry Health, Inc. · 2019
  12. Descendant · cites it directly · 10 of its ownK092620 MD300C318 Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2009
  13. Descendant · 2 generations on · 8 of its ownK142888 Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2015

Showing 5 of 40 descendants. See all descendants

Descendants cleared per year

2009: 12012: 22013: 12014: 12015: 22016: 12018: 12019: 32021: 12022: 72023: 32024: 72025: 72026: 3
2009high 7 (2022) · low 0 (2010)2026

Most influential descendants

Showing 5 of 40 · See all
  • K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015 · cites it directly24descendants
  • K181956Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2019 · 2 generations on23descendants
  • K181352Loop SystemSpry Health, Inc. · 2019 · 3 generations on10descendants
  • K092620MD300C318 Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2009 · cites it directly10descendants
  • K142888Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd. · 2015 · 2 generations on8descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K910772Propaq 102, 104 and 106Protocol Systems, Inc.1991—
−6K972020Oscillomate Non-Invasive Blood Pressure MonitorCas Medical Systems, Inc.1998—
−5K980879Oscillomate Nibp / SP02 Ems MonitorCas Medical Systems, Inc.1998—
−4K9827769303 Neonatal/Adult Vital Signs MonitorCas Medical Systems, Inc.1998—
−3K013319Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure (Nibp) MonitorNonin Medical, Inc.2002—
−2K041156Avant Digital Pulse Oximetry System, Models 4000, 4001Nonin Medical, Inc.20041
−1K0433594100 Patient Oximeter ModuleNonin Medical, Inc.2005—
0 (this device)K081285Finger Pulse Oximeter, Model 9560Nonin Medical, Inc.2008—
+1K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2015—
+2K181956Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2019—
+3K181352Loop SystemSpry Health, Inc.2019—
+1K092620MD300C318 Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd.2009—
+2K142888Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199210
199310
199510
199720
200020
200510
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201220
201310
201410
201520
201610
201810
201930
202110
202270
202330
202470
202570
202630
FIG. 1 — Lineage of K081285, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQA device

  1. #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053130Onyx II Finger Pulse Oximeter, Model 9550
Summary page 1
…1 CFR 870.2700 Product Code: DQA Predicate Device(s): The predicate devices are Nonin's Onyx II® Model 9550 Finger Pulse Oximeter, K053130, cleared on January 11, 2006 and Model 4100 Patient Oximeter Module, K043359, cle…
Nonin Medical, Inc.2006—
*K0433594100 Patient Oximeter Module
Summary page 1
…s Onyx II® Model 9550 Finger Pulse Oximeter, K053130, cleared on January 11, 2006 and Model 4100 Patient Oximeter Module, K043359, cleared on January 7, 2005. Device Description: The Model 9560 is a small, lightweight, portable fi…
Nonin Medical, Inc.2005—

Also cleared against K053130: 1 other device →

What descends from it? (40)

See all 40

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation201524
K092620MD300C318 Fingertip Pulse OximeterBeijing Choice Electronic Technololgy Co., Ltd.200910
K131021Pulse OximeterNonin Medical, Inc.20133
K113865PultolSharp Corporation20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 2.4 years on median.
  • 2 of the 17 ancestors have a recall of any class.
  • Of its descendants, K150314 (Masimo Corporation, 2015) has gone furthest, with 24 descendants of its own.
  • 1 other device also cites its predicate K053130.

How does its category compare?

All DQA devices

DQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · DQA

15in 2025

2007: 202008: 222009: 352010: 292011: 152012: 142013: 152014: 112015: 132016: 142017: 92018: 182019: 192020: 152021: 102022: 202023: 132024: 142025: 152026 (partial year): 8
2007high 35 (2009) · low 9 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQA

182in 2025

2007: 122 days median2008: 97 days median2009: 117 days median2010: 127 days median2011: 195 days median2012: 120 days median2013: 182 days median2014: 175 days median2015: 158 days median2016: 246 days median2017: 200 days median2018: 260 days median2019: 158 days median2020: 126 days median2021: 174 days median2022: 265 days median2023: 317 days median2024: 285 days median2025: 182 days median2026 (partial year): 187 days median
2007high 317 (2023) · low 97 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQA

3in 2024

2007: 62008: 52009: 292010: 42011: 12014: 22015: 12018: 322024: 3
2007high 32 (2018) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQA

399in 2025

2007: 3252008: 3122009: 2812010: 1852011: 1642012: 3222013: 4682014: 1,1242015: 2,0822016: 1,7752017: 1,1902018: 6942019: 5482020: 4262021: 5532022: 4782023: 3922024: 5452025: 399
2007high 2,082 (2015) · low 164 (2011)2025

MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007201226325
200822975312
20093511729281
2010291274185
2011151951164
2012141200322
2013151820468
20141117521,124
20151315812,082
20161424601,775
2017920001,190
20181826032694
2019191580548
2020151260426
2021101740553
2022202650478
2023133170392
2024142853545
2025151820399
202681870—

What is it indicated for?

The Nonin® Onyx II® Model 9560 Finger Pulse Oximeter is a small, lightweight, portable, device indicated for use in measuring and displaying functional oxygen saturation of arterial hemoglobin (Sp02) and pulse rate of patients who are well or poorly perfused. It is intended for spot-checking of adult and pediatric patients on fingers (other than the thumb) between 0.3 - 1.0 inch (0.8 - 2.5 cm) thick. The index finger is the recommended site.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K081285: Finger Pulse Oximeter, Model 9560.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K081285

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026