510(k) · Cleared
ClearedLaurimed Percutaneous Discectomy System, Model FG-000002
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Laurimed, LLC · HRX Arthroscope
Cleared on Aug 28, 2008 as substantially equivalent to K923525 (Surgical Dynamics, Inc., 1993) and 1 other predicate after a 24-day review. Its family tree reaches back 1 generation to 1991. 1 later device descends from it.
- Decided
- Aug 28, 2008
- Review
- 24 days
- Class
- Class II
- Product code
- HRX
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K914282 (1991). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 1 generation backK914282 Nucleotome (R) II (VERSION2) Tissue Aspira/CutterSurgical Dynamics, Inc. · 1991
- This deviceK082194 Laurimed Percutaneous Discectomy System, Model FG-000002Laurimed, LLC · 2008
- Descendant · cites it directly · 0 of its ownK090815 Percutaneous Discectomy SystemLaurimed, LLC · 2009
Most influential descendants
Showing 1 of 1 · See all- K090815Percutaneous Discectomy SystemLaurimed, LLC · 2009 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K914282 | Nucleotome (R) II (VERSION2) Tissue Aspira/Cutter | Surgical Dynamics, Inc. | 1991 | — |
| 0 (this device) | K082194 | Laurimed Percutaneous Discectomy System, Model FG-000002 | Laurimed, LLC | 2008 | — |
| +1 | K090815 | Percutaneous Discectomy System | Laurimed, LLC | 2009 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2009 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRX device
- #1 K260203 Fule Vertebroplasty Balloon Catheterscore 14.9 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K923525 | Nucleotome 3.5 MM Automated Percutaneous LumbarSummary page 1…Laurimed Percutaneous Discectomy System is substantially equivalent to Surgical Dynamics, Inc. Nucleotome 3.5mm Automated Percutaneous Lumbar Discectomy Kit (K923525) and Nucleotome II (Version 2) Tissue Aspirator/Cutter(K914282). F. Device Description The Laurimed Percutaneous… | 1993 |
| * | K914282 | Nucleotome (R) II (VERSION2) Tissue Aspira/CutterSummary page 1…o Surgical Dynamics, Inc. Nucleotome 3.5mm Automated Percutaneous Lumbar Discectomy Kit (K923525) and Nucleotome II (Version 2) Tissue Aspirator/Cutter(K914282). F. Device Description The Laurimed Percutaneous Discectomy System is intended to be used to cut and aspirate nu… | 1991 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K090815 | Percutaneous Discectomy System | 2009 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All HRX devicesHRX Arthroscope: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · HRX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRX
107in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRX
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRX
2,076in 2025
MAUDE reports naming product code HRX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 89 | 3 | 421 |
| 2008 | 9 | 115 | 13 | 441 |
| 2009 | 11 | 139 | 23 | 558 |
| 2010 | 9 | 114 | 12 | 612 |
| 2011 | 3 | 84 | 6 | 631 |
| 2012 | 11 | 102 | 0 | 778 |
| 2013 | 12 | 90 | 4 | 678 |
| 2014 | 9 | 140 | 0 | 802 |
| 2015 | 4 | 132 | 7 | 763 |
| 2016 | 8 | 89 | 0 | 469 |
| 2017 | 4 | 97 | 0 | 934 |
| 2018 | 12 | 101 | 1 | 1,581 |
| 2019 | 12 | 45 | 0 | 1,676 |
| 2020 | 7 | 141 | 0 | 1,706 |
| 2021 | 7 | 57 | 3 | 1,908 |
| 2022 | 3 | 89 | 0 | 1,406 |
| 2023 | 4 | 249 | 0 | 1,852 |
| 2024 | 6 | 110 | 1 | 2,427 |
| 2025 | 9 | 107 | 0 | 2,076 |
| 2026 | 7 | 217 | 0 | — |
What is it indicated for?
The Laurimed Percutaneous Discectomy System is indicated for use in aspiration of disc material during percutaneous discectomies in the lumbar region of the spine.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082194 · printed Nov 4, 2026
Cite this page
510(k) Report. “K082194: Laurimed Percutaneous Discectomy System, Model FG-000002.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K082194
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026