510(k) Report

510(k) · Cleared

Recalled · Class III · 2014

Laurimed Polypvac Microdebrider

K133133510(k) TraditionalCleared Dec 23, 201384-day reviewClass II21 CFR 874.4250Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Laurimed, LLC · ERL Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece

Cleared on Dec 23, 2013 as substantially equivalent to K041413 (Medtronic Xomed, Inc., 2004) after an 84-day review. Its family tree reaches back 2 generations to 2000. 2 later devices descend from it. It has been recalled once.

Decided
Dec 23, 2013
Review
84 days
Class
Class II
Product code
ERL
Recalls
1
Predicates
1

Its longest line of descent runs back 2 generations to K002224 (2000). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2017: 1 descendant clearedK002224 · XPS 3000 System · Medtronic Xomed · 2000K041413 · XPS 3000 System · Medtronic Xomed, Inc. · 2004200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K041413 · XPS 3000 System · Medtronic Xomed, Inc. · 2004K002224 · XPS 3000 System · Medtronic Xomed · 20000
  1. Root · 2 generations backK002224 XPS 3000 SystemMedtronic Xomed · 2000
  2. 1 generation backK041413 XPS 3000 SystemMedtronic Xomed, Inc. · 2004
  3. This deviceK133133 Laurimed Polypvac MicrodebriderLaurimed, LLC · 2013
  4. Descendant · cites it directly · 1 of its ownK161101 PolypVac Microdebrider (3.3mm and 4.0mm)Laurimed, LLC · 2016
  5. Descendant · 2 generations on · 0 of its ownK163247 3.3 mm Laurimed Microdebrider; 4.0 mm Laurimed MicrodebriderLaurimed, LLC · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K161101PolypVac Microdebrider (3.3mm and 4.0mm)Laurimed, LLC · 2016 · cites it directly1descendant
  • K1632473.3 mm Laurimed Microdebrider; 4.0 mm Laurimed MicrodebriderLaurimed, LLC · 2017 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002224XPS 3000 SystemMedtronic Xomed2000—
−1K041413XPS 3000 SystemMedtronic Xomed, Inc.2004—
0 (this device)K133133Laurimed Polypvac MicrodebriderLaurimed, LLC2013—
+1K161101PolypVac Microdebrider (3.3mm and 4.0mm)Laurimed, LLC2016—
+2K1632473.3 mm Laurimed Microdebrider; 4.0 mm Laurimed MicrodebriderLaurimed, LLC2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201710
FIG. 1 — Lineage of K133133, 2000–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ERL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ERL device

  1. #1 K243280 Piezomed Pro (Piezomed Pro module M-PM100…score 12.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041413XPS 3000 System
Summary page 2
…Microdebrider F. Predicate Devices The Laurimed PolypVac Microdebrider is substantially equivalent to the Medtronic Xomed, Inc., XPS 3000 System (K041413). G. Device Description The Laurimed PolypVac Microdebrider is intended for cutting and aspirating polyp tissue…
Medtronic Xomed, Inc.2004—

Also cleared against K041413: 4 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161101PolypVac Microdebrider (3.3mm and 4.0mm)Laurimed, LLC20161

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 7, 2014Class IIIZ-1527-2014Component design/selectionThe reciprocation mechanism in the PolypVac Microdebrider may turn off prematurely due to a component failure in the device handle.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 9.4 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K161101 (Laurimed, LLC, 2016) has gone furthest, with 1 descendant of its own.
  • 4 other devices also cite its predicate K041413.

How does its category compare?

All ERL devices

ERL Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · ERL

1in 2025

2008: 62009: 12012: 22013: 22014: 12015: 32016: 42017: 22018: 12019: 12020: 12021: 12022: 32024: 12025: 1
2007high 6 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ERL

191in 2022

2008: 181 days median2015: 86 days median2016: 180 days median2022: 191 days median
2007high 191 (2022) · low 86 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ERL

1in 2021

2009: 12013: 32020: 52021: 1
2007high 5 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ERL

1,469in 2025

2007: 1122008: 602009: 2492010: 4442011: 1,0682012: 1,3792013: 3,2312014: 1,9752015: 2,6302016: 1,4552017: 9992018: 1,3802019: 2,5152020: 2,3692021: 2,2832022: 1,5742023: 1,7252024: 1,5882025: 1,469
2007high 3,231 (2013) · low 60 (2008)2025

MAUDE reports naming product code ERL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—0112
20086181060
20091—1249
20100—0444
20110—01,068
20122—01,379
20132—33,231
20141—01,975
201538602,630
2016418001,455
20172—0999
20181—01,380
20191—02,515
20201—52,369
20211—12,283
2022319101,574
20230—01,725
20241—01,588
20251—01,469
20260—0—

What is it indicated for?

Indicated for the excision of polyps in the nasal passageways and in sinuses for which access has been previously established.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K133133: Laurimed Polypvac Microdebrider.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K133133

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026